background image

2. TOOLS REQUIRED (NOT SUPPLIED)

1. INTRODUCTION 

This booklet contains all the necessary fitting and 

operating instructions for your MX Thermostatic bar 

mixer valve.

Please read these instructions carefully. Read 

through the whole of this book before beginning your 

installation. 

The installation MUST be carried out by a suitably 

competent person after reading these instructions.

Care taken during the installation will provide a long 

and trouble free life from your shower. For the best 

performance within the specified running pressure 

range a minimum flow of 5 litres per minute should 

be available on both inlets.

This mixer valve is designed to operate on higher 

pressure systems up to a maximum of 5 bar running 

pressure. The mixer valve must not be subjected to 

water temperatures above 80˚C. This mixer valve is 

also suitable for thermal storage, unvented systems 

and pumped gravity systems.

IMPORTANT: Before installing with a gas 

instantaneous water heater, make sure it is capable 

of delivering hot water at a minimum switch-on flow 

rate of 3 litres per minute. 

At flow rates between 3 and 8 litres per minute, 

the appliance must be capable of raising the water 

temperature to a minimum of 52˚C.

The water temperature at the inlet to the mixer valve 

must remain relatively constant when flow rate 

adjustments are made (refer to the water heater 

operating manual to confirm compatibility with this 

mixer valve).

HB

Silicone

Spanner / Wrench

Tape Measure

Screwdriver

Pencil

Power Drill

Suitable Drill Bits

Silicone Sealant

Spirit Level

Safety Eyewear

NOTE: Additional plumbing tools and fittings may be required.

Summary of Contents for Atmos Sigma

Page 1: ...Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation Atmos Sigma Thermostatic Bar Mixer Valve ...

Page 2: ...mumof5barrunning pressure Themixervalvemustnotbesubjectedto watertemperaturesabove80 C Thismixervalveis alsosuitableforthermalstorage unventedsystems andpumpedgravitysystems IMPORTANT Beforeinstallingwithagas instantaneouswaterheater makesureitiscapable ofdeliveringhotwaterataminimumswitch onflow rateof3litresperminute Atflowratesbetween3and8litresperminute theappliancemustbecapableofraisingthewat...

Page 3: ...IMPORTANT This Step by Step guide should be retained after installation Dogleg Thread Adaptor Please make sure ALL components are included before starting the installation Description Quantity BarMixerValve 1 DoglegThreadAdaptors 2 NutCovers 2 FilterWashers 2 FittingInstructions 1 RegistrationCard 1 ...

Page 4: ...ndent method of isolating the shower should maintenance or servicing be necessary these valves SHOULD NOT restrict the flow DO NOT operate the shower outside the recommended temperatures and pressures stated in this guide Always test the water temperature with your hand before entering the shower NOTE As a competent person installing this shower you should ensure that all users are very conversant...

Page 5: ... Itis veryimportantthatforuseinanymainspressure systemsanexpansiontankandapressurereducing valvehasbeenfittedtoensurethepressuredoes notexceed5Bar Thisshouldbeconfirmedbytheinstallation engineerorcompetentperson beforeinstallation WATER TEMPERATURE REQUIREMENTS Maximumhotwatertemperature 80 C Recommendedmaximum 65 C Minimumhotwatertemperature 55 C Maximumcoldwatertemperature 20 C TEMPERATURE ADJUS...

Page 6: ...asaredsymbol nexttotheinletandmustbeonthelefthandside If themixervalveyouarefittingiswithariserrailthe outletshouldpointdown ifthemixervalveisforan overheadtheoutletshouldpointupwards n Themixervalveisdesignedtoworkatthesame hotandcoldwaterpressures Ifthisisnotthecasea flowcontroller discwithsmallholes canbefittedto thehigherpressuresupplytothevalve Thisisbest donebytestingeachonetofindoutwhichgiv...

Page 7: ...hefittings makingsure thesealingwashersareinplace screwtheunions ontothefittings Themixervalvemustbepositioned horizontallywiththehotsupplyonthelefthandside oftheoutlet Fig3 NOTE Ensureyouhavethecorrectvalvewiththe wateroutletonthebottomwhenthehotwaterinletis totheleft 1 2 3 9 OPERATION Thereare2controlhandlesonthemixervalve TO CONTROL THE FLOW Turntherightcontrolhandleanti clockwisetoturnonandinc...

Page 8: ...lets 3 Overridethetemperaturestopbuttonbypressing thebuttonandrotatetomaximumbeingcarefulto avoidscalding Measurethetemperature 4 Thevalveshouldthenbecheckedtoconfirmthe waterisolationperformscorrectly Runthevalveat the38 Cstopposition Checkthewatertemperature 5 Turnoffthefeedofcoldwaterusingtheisolation valve Thewaterflowshouldfalltoaverylowflow possiblyonlyadrip afterafewseconds 6 Collectthewate...

Page 9: ...vevalveandcleanfilters 4 Showerheadblocked CleanShowerhead 5 Systemnotcapableofsupplyingmultipleoutlet atthesametime Reducesimultaneousdemand Checkstop servicevalvesarefullyopen Checkifenough waterpressure Q WatertooCOLD A Ninethingstocheck 1 Temperaturecontrolisnotcorrectly commissioned Adjustthetemperaturecontrol thisisonlyajob forasuitablyqualifiedperson 2 Notenoughhotwaterflowingthroughshower ...

Page 10: ...yMXGrouptoyouthecustomer 2 Thisguaranteeispersonaltotheoriginalpurchaserofthe componentandisnottransferable 3 Originalproofofpurchase s mustbeshownforanyclaim underthisguarantee 4 Thisguaranteedoesnotcoveranycomponentsthathavebeen modified alteredortransformedinanyway 5 Thisguaranteeappliestoanoriginalinstallationinaccordance toourfittinginstructionsanddoesnotcoverpreviouslyinstalled components sh...

Page 11: ...rcontactdetails andthepostcodewheretheunitisinstalled 2 TheMXGroupCustomerServiceDepartmentwill beabletotellyouwhetherthefaultcanbesimply rectifiedbytheprovisionofareplacementpart 14 SPAREPARTS Intheeventthatpartsormaintenanceisneeded outsidetheguaranteeMXwillendeavourtohelp withthis Sparepartscodesaregiveninthefitting instructions BycallingtheCustomerService Departmenton08455052211withthepart num...

Page 12: ...il sales mx group com www mx group com CUSTOMERCARE 08455052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish materials and all other aspects of appearance may occur on occasions either through non availability of materials or due to our policy of continuing technical improvement Therefore the Company reserves the right to change specification or withdraw products from this list with...