background image

 33

EN

M1.2.CUT45HF.NLFREN   09102018

2�2  Composition of the cutting machine system




 产



3

1.4 Composition and configuration of the cutting machine system

1

)

Composition

 

Figure 1-3

Composition of the cutting machine system

2 Configuration

)

 

Table 1-3

Configuration of CUT40

(

L202

)

Table 1-4

Configuration of CUT40C

(

L203

)

Cutting machine

1. GENERAL

 DESCRIPTION

CUT40

(

L202

)

300A-6mm

²

-KDP16D

(

3m

)

LT50

Name

Specification

Quantity pcs

 

(

)

Remark

Material code

Cutting torch

Earth clamp

Operator’s manual

L2030A SC/A0

Standard configuration
Standard configuration
Standard configuration
Standard configuration

10048700

10003276

10048735

10048725

1
1
1
1

Cutting machine

CUT40

(

L203

)

C

300A-6mm

²

-KDP16D

(

3m

)

PT40

-

S

Name

Specification

Quantity pcs

 

(

)

Remark

Material code

Cutting torch

Earth clamp

Operator’s manual

L2030A SC/A0

Standard configuration
Standard configuration
Standard configuration
Standard configuration

10047859

10003276

10048736

10048725

1
1
1
1

Composition:

•  Cutting machine

•  Cutting torch

•  Earth clamp

2�3  Functions and characteristics of the cutting machine

CUT45HF is an ultra-portable plasma cutting system suitable for a variety of application requirements. It can be used in 

handheld cutting and robot cutting as well. CUT45HF can cut conductive metal, such as low carbon steel, stainless steel 

and aluminium. The cutting thickness can reach up to 25.4 mm and perforating thickness can reach up to 12 mm.

Advanced digital control mode

Plasma cutting machine CUT45HF adopts international leading MUC intelligent digital control technology, and all its 

major parts are performed through software. It is a digital control plasma cutting machine, improved a lot in its function 

and performance when compared with the traditional plasma cutting machine.

Advanced inverter technology

The machine adopts switching power supply inverter technology, greatly reducing the volume and weight of the plasma 

cutter, and obviously enhancing the conversion efficiency. Switching frequency is beyond audiorange, which almost 

eliminates the noise pollution.

Good consistency and stable performance

Generally speaking, for a cutting machine with analogue circuit control or with analogue circuit & digital circuit control, 

the performance characteristics are decided by the parameters of various components. Cutting performance of the 

machines differ as a result of the inconsistent parameters of the components, so even for the cutting machines of the 

same brand, their parameters often differ from each other. In addition, cutting performance of the machine may change 

on some extent, since parameters of the components may vary according to the environment such as temperature and 

humidity, etc.

One of the characteristics of digital control is that it is not sensitive to the change of parameters; the performance of 

cutting machine will not be affected by the change of the parameters of certain parts. Therefore, the consistency and 

stability of digital control cutter is better than that of traditional cutter.

copyrighted 

document 

- all 

rights 

reserved 

by 

FBC

Summary of Contents for 829300220

Page 1: ...ijder D coupeur plasma Plasma cutter P 02 Gelieve te lezen en voor later gebruik bewaren P 16 Veuillez lire et conserver pour consultation ult rieure P 30 Please read and keep for future reference FR...

Page 2: ...e 5 2 4 Kenmerken van het systeem 6 3 Installatie en aansluiting 7 3 1 Aansluitingsvoorwaarden 7 3 2 Veiligheidsvoorschriften 8 4 Gebruik 9 4 1 Functies van de voor en achterpanelen 9 4 2 Digitaal pan...

Page 3: ...s falling into the machine inside when replacing the components SAFETY Precautions for installation Beware of electric shock Install grounding device according to application standard Do not touch liv...

Page 4: ...ed to operate the fire extinguisher Do not weld closed container Do not use this machine for pipe thawing Hot workpiece can cause severe scald Do not touch hot workpiece with bare hands Cool the weldi...

Page 5: ...odus De CUT45HF gebruikt de MUC intelligente digitale controle technologie en alle belangrijkste onderdelen worden door middel van de software uitgevoerd Zijn werking en zijn rendement zijn aanzienlij...

Page 6: ...A I 80 60 40 20 50 40 30 20 10 0 U2 V U0 2 A I 0 5 1 6 System characteristics Figure 1 4 Duty cycle Figure 1 5 Output characteristic curves 1 Duty cycle 2 Output characteristics External characterist...

Page 7: ...tching box should meet the requirements of the maximum input capacity of the machine 2 Connection of output cable 2 INSTALLATION AND CONNECTION CUT40 should be located close to the corresponding power...

Page 8: ...het gewicht ervan kan dragen Installeer de machine niet op plaatsen waar spatten mogelijk zijn of in de nabijheid van waterleidingen De snijwerken moeten in een droge omgeving plaatsvinden met een vo...

Page 9: ...ions of L202 L203 L20301 1 2 3 4 1 2 3 1 2 3 4 No Part name Current control knob T Gas pressure gauge T g Quick socket T T Power cable Gas connector T Gas electric connector 1 2 3 No Part name T Nr Om...

Page 10: ...nt the machine cannot cut Metal mesh cutting indicator The machine can cut metal mesh when this indicator illuminates The machine is under normal cutting status when neither of the indicators illumina...

Page 11: ...operation It is recommended not to ignite the arc in the air if not necessary for it will shorten the lifespan of the electrode and nozzle of the torch It is recommended to initiate the cutting from t...

Page 12: ...be replaced Otherwise there will be strong arc in the nozzle which will break down the electrode and the nozzle or even burn the torch Nozzles of different models are different so ensure the nozzle is...

Page 13: ...an de voedingskabel Controleer of de luchtinlaat niet verstopt is Afdekkap Controleer of de bouten goed aangedraaid zijn Indien nodig draai vast of vervang losse bouten Behuizing Controleer of de schr...

Page 14: ...rofessionals to ensure safety Thepower of the switching box and the cutting machine should be shut down before periodic check to avoid personal injury accidents such as electric shock and burns Due to...

Page 15: ...van de snijtoorts ingedrukt wordt 1 De LED 1 van het hoofdpaneel is aan de controle circuit is beschadigd 2 De LED 1 van het hoofdpaneel is uit controleer de trekker en de kabel van de trekker De mac...

Page 16: ...4 Caract ristiques du syst me 20 3 Installation et branchement 21 3 1 Conditions d installation 21 3 2 Consignes de s curit 22 4 Utilisation 23 4 1 Fonctions des panneaux avant et arri re 23 4 2 Panne...

Page 17: ...se there is a risk of damage to property Make sure there are no foreign bodies such as wire leads screws gaskets and metal bars falling into the machine inside when replacing the components SAFETY Pre...

Page 18: ...nearby and make sure someone has been trained to operate the fire extinguisher Do not weld closed container Do not use this machine for pipe thawing Hot workpiece can cause severe scald Do not touch...

Page 19: ...et l paisseur de perforation 12 mm Mode de contr le digital avanc La machine CUT45HF utilise la technique digitale de contr le intelligent MUC et toutes ses pi ces principales sont effectu es par le l...

Page 20: ...chine Q 100 A I 80 60 40 20 50 40 30 20 10 0 U2 V U0 2 A I 0 5 1 6 System characteristics Figure 1 4 Duty cycle Figure 1 5 Output characteristic curves 1 Duty cycle 2 Output characteristics External c...

Page 21: ...he maximum input capacity of the machine 2 Connection of output cable 2 INSTALLATION AND CONNECTION CUT40 should be located close to the corresponding power socket For CSA or CE standard single phase...

Page 22: ...poids N installez pas la machine un endroits o il peut y avoir des claboussures ou proximit de conduites d eau Le d coupage doit tre effectu dans un environnement sec avec un taux d humidit de 90 ou...

Page 23: ...3 L20301 1 2 3 4 1 2 3 1 2 3 4 No Part name Current control knob T Gas pressure gauge T g Quick socket T T Power cable Gas connector T Gas electric connector 1 2 3 No Part name T N D nomination Foncti...

Page 24: ...0301 10 Figure 3 3 Digital panel of L202 L203 3 OPERATION 3 2 Digital Panel of L202 L203 L20301 2 5 3 5 4 0 A 2 0 30 CUT40 20 0 40 60 80 100 120 140 150 psi kg cm 6 7 8 9 1 0 5 4 3 2 No 1 2 3 4 5 6 7...

Page 25: ...the position about 1mm above the workpiece and start cutting 3 4 Notes for cutting operation It is recommended not to ignite the arc in the air if not necessary for it will shorten the lifespan of the...

Page 26: ...below occur the electrode and nozzle should be replaced Otherwise there will be strong arc in the nozzle which will break down the electrode and the nozzle or even burn the torch Nozzles of different...

Page 27: ...mentation et sa fixation V rifiez si l entr e d air n est pas bouch e Capot V rifiez si les boulons sont bien serr s Si n cessaire resserrez ou remplacez les boulons desserr s Ch ssis V rifiez si les...

Page 28: ...alified professionals to ensure safety Thepower of the switching box and the cutting machine should be shut down before periodic check to avoid personal injury accidents such as electric shock and bur...

Page 29: ...z la g chette de la torche 1 La LED 1 du panneau principal est allum e le circuit de commande est endommag 2 La LED 1 du panneau principal est teinte v rifiez la g chette et le c ble de la g chette La...

Page 30: ...e 33 2 4 System characteristics 34 3 Installation and connection 35 3 1 Installation requirements 35 3 2 Precautions 36 4 Operation 37 4 1 Panel functions 37 4 2 Digital panel 38 4 3 Operating method...

Page 31: ...de when replacing the components SAFETY Precautions for installation Beware of electric shock Install grounding device according to application standard Do not touch live parts with naked skin wet glo...

Page 32: ...perate the fire extinguisher Do not weld closed container Do not use this machine for pipe thawing Hot workpiece can cause severe scald Do not touch hot workpiece with bare hands Cool the welding torc...

Page 33: ...ma cutting machine CUT45HF adopts international leading MUC intelligent digital control technology and all its major parts are performed through software It is a digital control plasma cutting machine...

Page 34: ...60 40 20 50 40 30 20 10 0 U2 V U0 2 A I 0 5 1 6 System characteristics Figure 1 4 Duty cycle Figure 1 5 Output characteristic curves 1 Duty cycle 2 Output characteristics External characteristic of m...

Page 35: ...aximum input capacity of the machine 2 Connection of output cable 2 INSTALLATION AND CONNECTION CUT40 should be located close to the corresponding power socket For CSA or CE standard single phase powe...

Page 36: ...place to install the machine can bear the weight of the cutting machine Do not install the machine at places where water droplet splash may be produced such as near water pipes Cutting should be carri...

Page 37: ...ons of L202 L203 L20301 1 2 3 4 1 2 3 1 2 3 4 No Part name Current control knob T Gas pressure gauge T g Quick socket T T Power cable Gas connector T Gas electric connector 1 2 3 No Part name T No Par...

Page 38: ...cut Metal mesh cutting indicator The machine can cut metal mesh when this indicator illuminates The machine is under normal cutting status when neither of the indicators illuminates L20301 10 Figure 3...

Page 39: ...is recommended not to ignite the arc in the air if not necessary for it will shorten the lifespan of the electrode and nozzle of the torch It is recommended to initiate the cutting from the edge of w...

Page 40: ...de and nozzle When the phenomena below occur the electrode and nozzle should be replaced Otherwise there will be strong arc in the nozzle which will break down the electrode and the nozzle or even bur...

Page 41: ...k panel Whether the input power cable and buckle are in good condition Whether the air intake is unobstructed Cover Whether the bolts are loosely connected If unqualified tighten or replace the compon...

Page 42: ...of the switching box and the cutting machine should be shut down before periodic check to avoid personal injury accidents such as electric shock and burns Due to the discharge of capacitors checking...

Page 43: ...is no response when pushing the torch trigger 1 The LED 1 on the main board is on The control PCB is damaged 2 The LED 1 on the main board is off Check the torch trigger and torch trigger wire Turn o...

Page 44: ...ide richtlijnen met inbegrip van deze betreffende het tijdstip van de verklaring der geldende veranderingen R pond aux normes g n rales caract ris es plus haut y compris celles dont la date correspond...