Troubleshooting:
Will not start inject or has stopped during injection sequence
Check incoming air supply
Apply correct pressure and CFM to unit.
Stop button has been pushed
Remote stop button pushed
Restart injection sequence.
PPVS signal not being received
Install jumper between PPVS supply and PPVS signal if no PPVS is being used.
Check signal coming from PPVS if installed.
Internal PPVS circuit check.
Check line (67) for leaks
Check V08 output (41) for signal. Should be on.
MPG circuit is engaged
Check for blockage on resin delivery lines.
Check FC #03 for proper adjustment.
Check for air leaks on MPG valve and connection 1B-11(26).
Internal MPG circuit check
Check (26) for leaks.
Check (67) for leaks
Check V14 output (62) for signal. Should be on.
Check V15 output (05) for signal. Should be on.
Stop sequence has been imitated
Internal Stop sequence circuit check.
Check (16) for signal. Should be off.
Remote stop button has malfunctioned.
Check (15) for signal. Should be off.
CE NORM guard valve has malfunctioned.
Check (37) for signal. Should be off.
Stop pushbutton (PB06) has malfunctioned.
Check (39) for signal. Should be off.
Pulse valve (S01) has malfunctioned. See below.
Check (49) for signal. Should be off.
Catalyst Overpressure circuit is engaged. See below.
Check (48) for signal. Should be off.
Predetermined counter has not reset or malfunctioned. See below.
CE NORM guard has been opened
Close CE NORM guard
Check CE NORM guard valve for proper operation
Pulse valve has malfunctioned
Internal Pulse valve circuit check.
Check (36) for signal. Should not be on.
Note: This valve also resets all circuits to off when air pressure to the system is moved from an off state to on. If
circuits are not resetting on startup then this valve is faulty.
Summary of Contents for Patriot Megaject Innovator II
Page 1: ...Patriot Megaject Innovator II Operation Manual Rev 04 2014 ...
Page 55: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 55 ...
Page 56: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 56 ...
Page 57: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 57 ...
Page 58: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 58 ...
Page 60: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 60 ...
Page 61: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 61 ...
Page 62: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 62 ...
Page 63: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 63 ...
Page 64: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 64 ...
Page 65: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 65 ...
Page 66: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 66 ...
Page 67: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 67 ...
Page 68: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 68 ...
Page 69: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 69 ...
Page 70: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 70 ...
Page 71: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 71 ...
Page 72: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 72 ...
Page 73: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 73 ...
Page 74: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 74 ...
Page 75: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 75 ...
Page 76: ...Patriot Megaject Innovator II Operations Manual Rev 04 2014 Page 76 ...