MVE 21135284 Quick Reference Manual Download Page 6

MVE FUSION Quick Reference Guide 

 

6 – 21205647 D 

 

This manual includes the following symbols. 

Table 1: the symbols and their descriptions

 

Symbol 

Title 

Description 

 

Caution 

Signifies a CAUTION of potentially hazardous 

situation when operating the device that may result in 

minor to moderate injury or property damage. 

 

Warning 

 

 

Signifies a WARNING of a potentially hazardous 

situation when operating the device that may result in 

serious injury or property damage.  

 

Warning; Low 

Temperature 

 

 

Indicates low temperature or freezing conditions. Take 

care to avoid exposure to skin, eyes, and clothing.  

 

Warning; 

Asphyxiating 

Atmosphere 

 

 

Indicates the potential for an oxygen-depleted 

atmosphere due to nitrogen vapor. Take care to 

operate device in a well-ventilated area.  

 

Warning; Electricity 

 

 

Indicates a potential electrical hazard. Take care to 

avoid contact with electricity.  

 

Warning; Explosive 

 

 

Indicates a potential explosive hazard. The expansion 

ratio of liquid nitrogen to gas is 1:700 and can cause 

explosive conditions if placed into a sealed container.  

 

Wear Protective 

Gloves 

 

 

Thermal gloves must be worn during indicated 

procedures.  

 

Wear a Face Shield 

 

 

A face shield must be worn during indicated 

procedures. 

 

ETL Listed Mark 

 

 

Chart Fusion Freezer is conformed to UL STD 61010-

1 and certified to CSA STD C22.2#61010-1. 

 

WARNING: Do not modify this equipment without authorization of the manufacturer. 

Summary of Contents for 21135284

Page 1: ...MVE Fusion Series...

Page 2: ...y Chart Personal or an authorized MVE Distributor per the MVE Fusion Technical Manual PN 20994124 Product Identification Safety 3 Display Control Panel 7 Back Panel Electrical Physical Connections 8 D...

Page 3: ...al Conductivity Gas 25 83 mW m K Heat of Vaporization Liquid 198 38 kJ kg Density 1 atm Liquid 1 782 lbs L 807 4 g L 808 6 kg m3 Liquid Nitrogen Safety Transferring LN2 and operating the MVE Fusion sh...

Page 4: ...aseous nitrogen when evaporated The two most important safety aspects to consider when handling LN2 are adequate ventilation and eye and skin protection Although nitrogen gas is non toxic it is danger...

Page 5: ...asphyxia such as headache drowsiness dizziness excitation excess salivation vomiting or unconsciousness are observed remove to fresh air If breathing has stopped give artificial respiration CALL A PHS...

Page 6: ...ng Asphyxiating Atmosphere Indicates the potential for an oxygen depleted atmosphere due to nitrogen vapor Take care to operate device in a well ventilated area Warning Electricity Indicates a potenti...

Page 7: ...Display A Liquid Crystal Display LCD shows the value of all the current conditions including Freezer Temperature and LN2 level The display also shows any current alarm conditions that may exist RTD Pr...

Page 8: ...nel Electrical Physical Connections 1 RTD Temperature Probe Connection 2 Global Alarm Contacts These connections monitor All Alarms 3 Service Serial Port 4 Service Serial Port 5 Input Power 6 Main Pow...

Page 9: ...lternate inventory systems into the MVE Fusion NOTE VERY IMPORTANT TO ADD RACKS AND BOXES BEFORE FILLING CAUTION Venting may occur which will result in a loss of cryogen inside the pressure vessel if...

Page 10: ...2 to the Fusions inlet valve using the supplied transfer hose with the cane oriented in the vertical position so the pressure relief valve can vent downwards NOTE One temperature probe will be factory...

Page 11: ...installed in the secondary sensor tube the tube should remain plugged with the factory installed plug 5 Shut off the two isolation valves located underneath the shroud on both sides of the liquefier 6...

Page 12: ...at room temperature for the first fill charge fill the internal sample storage area with 20 30 liters of LN2 through the neck of the tank using the second LN2 supply tank with another transfer hose h...

Page 13: ...e 50 PSIG inside of the storage tank As the internal chamber and storage racks come down to temperature the relief events will decrease 15 Once all the steps above have been completed the MVE Fusion c...

Page 14: ...he factory using a two point low temperature range calibration method This calibration method provides a level of accuracy of 1 8 F 1 C when operating at altitudes between 1000ft to 1500ft 305m to 457...

Page 15: ...erature is out of the allowable range REJECT T OUT OF RANGE Cryocoolers reject temperature is out of the allowable range TEMP A OUT OF RANGE RTD temperature out of the allowable range TEMP A SHORT Iss...

Page 16: ...MVE FUSION Quick Reference Guide 16 21205647 D NOTES...

Page 17: ...change the prices materials equipment quality descriptions specifications and or processes to its products at any time without prior notice and with no further obligation or consequence All rights no...

Reviews: