![MUTOH RJ-900C series Installation Manual Download Page 4](http://html.mh-extra.com/html/mutoh/rj-900c-series/rj-900c-series_installation-manual_1860167004.webp)
RJ-900C series INSTALLATION MANUAL
RJ900CE-I-00
4
300
100
300
500
2
1
1
600
~
800
567
1
2
a
b
c
d
e
3.3 Detaching protective materials
This product has protective materials in the place
shown below.
Detach all protective materials in accordance with the
following steps.
1. Remove all tapes from each cover.
2. Open the front cover and unscrew the butterfly
screws, and detach the fixing head unit protective
materials (metal plate).
This completes detaching protective materials.
4 Installation
Procedures and environment for installing this product
are explained.
4.1 Installation environment
Install this product to the appropriate place with refer-
ence to the following.
Do not install the plotter in the follow-
ing places where there is a possibility
that the plotter may be damaged or
might fall or be fallen by chance.
On a shaky stand
Slanting location
Places where vibration of other machines
etc. is transmitted.
Do not stamp on the plotter or do not
place heavy things on top of it. The plot-
ter may be damaged or might fall or be
fallen by chance.
Cover the plotter with blanket and cloth
like tablecloth and do not close the vent.
If the vent is closed, the plotter could ac-
cumulate heat inside and may cause
fire.
Do not install the plotter in a location
that has high humidity or is dusty.
It could lead to electric shock and fire.
4.1.2 Installation space
(1) When using the plotter with the stand
Install on a level floor which meets the following con-
dition.
It has enough strength to support the weight of
the plotter and the stand.
(2) When using the plotter only (RJ-901C only)
Install on a level table that meets the following condi-
tions.
The table has enough strength to support
the weigh of the plotter.
The required length for the sheet media is available
in the back.
The height from the floor is 600 mm to 800 mm.
The space in the front is more than 300 mm.
Printed sheets are not folded or dirtied.
4.1.3 Installation procedure
Install this product to the installation place in accord-
ance with the list shown below.
(1) When using the plotter with the stand
1. Check that the two butterfly bolts attaching the
stand and the plotter are not loose.
2. Carry the plotter to the installation place.
3. Lock two casters on the front side.
4. Check that the two butterfly bolts attaching the
stand and the plotter are not loose.
(2) When using the plotter only (RJ-901C only)
1. Carry the plotter to the installation place.
No.
Name
No.
Name
1 Rubber feet
No.
Name
No.
Name
1
Casters
2
Caster locks
No.
Name
No.
Name
Fixing head unit protective
materials (metal plate)
2
Butterfly screw
1
For temperature and humidity, avoid locations such
as the following. There is a possibility that the print
quality will be affected.
Places where temperature or humidity may rapidly
change, even though within the required conditions.
Places that receive direct sunlight, increased illumination
or direct air, for example from an air conditioner.
To keep the temperature and humidity constant,
install this product in a location where the air
condition is adjustable.
For the weight of the plotter and the stand, refer to
the Operation Manual.
WARNING
Please check that the butterfly bolts are not loose
before/after carrying this product.
When transferring or carrying outside, separate the
plotter and the stand.
For the weight of the plotter, refer to the Operation
Manual.
When using the plotter only (without the stand),
always arrange as shown below.
There is a possibility that the printed sheets are
affected or errors such as media jams occur.
RJ-901C
a=180mm
b=450mm
c=480mm
d=300mm
e=1198mm
RJ-900C
a=180mm
b=450mm
c=480mm
d=300mm
e=1198mm
Power
Specifica-
tion
Environm-
ental
conditions
Floor strength of
installation place
More than 2940 Pa (300 kg/m
2
)
Power
Supply
Frequency
Range
AC90V - 132V/198V - 264V
50/60Hz ± 1Hz
Power
capacity
Change
rate
Operative
condition
Archiving
environment
Guaranteed
range of
printing
accuracy
More than 10 A
Temperature:10 °C-35 °C
Humidity: 20 % - 80 %, No Condensation
Temperature:15 °C - 2 8°C
Humidity: 40 % - 60 %
Temperature: within 2 °C per hour
Humidity: within 5 % per hour
Temperature:-20° C - 60 °C
Humidity: 5 % - 85 % ,
No Condensation (Ink unfilled)
NOTE
NOTE
NOTE
NOTE
NOTE