PJ-2646NXE INSTALLATION MANUAL
13
4.1.1 Installation environment Requirements
Choose a place for printer installation following the requirements of the table below.
Area 12.6m
2
(146ft
2
) or larger. Frontage of 4.7m(15.7ft) or greater.
Floor loading capability
2940Pa (300kg/m
2
) or over
Voltage
AC100V – 120V / AC220V – 240V
±
10%
Frequency 50/60Hz
±
1Hz
Electrical
Capacity
AC100V – 120V: 15A or more
AC220V – 240V: 7.5A or more
Operational
conditions
Humidity
(%)
70
65
60
40
35
30
0
18 20 22
28 30 32
Temperature( )
Recommended operation
environment
Use operation environment
Recommended environment
when using the winding unit
Environmental
Storage
environment
Temperature: –10
℃
(14F) to 60
℃
(140F)
Humidity: 20
%
to 80
%
without condensation
NOTE
NOTE
Avoid the following temperature and humidity conditions. Otherwise, printed images may appear differently from
what you expect.
Places where sudden changes in temperature and humidity are expected, even though the condition is within the
range written above
Places where direct sunlight or excessive lighting are expected
Places where air conditioners blow directly
MUTOH recommends that the printer should be installed where air conditioning can be adjusted easily.