INSTALLATION

Content of the Box

The unit was packed carefully. Nevertheless we recommend to check the 
content directly after opening the package:

1 x FORMAT CHANGER advanced
1 x Power cable
4 x Rubber feets
1 x Manual
1 x Registration card

Placing the Device

The unit should be set up as closely as possible to the devices to which it 
will be connected, so as to avoid excessive cable lengths. Use the 4 rubber 
feets enclosed with the appliance and stick them symmetrically on the 
bottom side of the unit to protect the enclosure and supporting surface 
from being damaged. When the unit is installed in a rack, the rubber feets 
should not be used to save space!

For 19“ rack installation MUTEC offers an optional set of rack ears 
(MW-01/19 order no. 8020-005). Install the device so that one unit of rack 
space is left free above the device to allow for sufficient ventilation! The 
mounting depth including the terminals is 180 mm/7.07“. 
Another 150 mm/5.9“ should be added for the required cables.

Never expose the device and accessories to rain, moisture, direct sunlight, 
or excessive heat produced by radiators, heaters, or spot lights! Sufficient 
air circulation in the environment of the device must be ensured!

Wiring the Word Clock Interfaces

To allow for the synchronization of signals, the interfaces of all devices 
involved must be properly connected to each other, so as to ensure a logi-
cal signal flow. Always be sure to connect the Word Clock output of the 
FORMAT CHANGER advanced to the corresponding input of the devices you 
wish to synchronize! Cable lengths should be kept as short as possible to 
minimize signal losses and/or interferences!

For the transmission of Word Clock signals electrical, unsymmetrical cables 
with a resistance of 75 

 and BNC connectors on both ends are used. Typi-

cally, such cables are marked »RG-59U, RG59B/U«.

Additionally, you should make sure that the Word Clock inputs to be con-
nected to the FORMAT CHANGER advanced’s output have a 75 

 termi-

nating resistor! Most Word Clock inputs allow for enabling/disabling the 
termination with a so-called »termination-switch«, which may be located 
on the outside or inside of the device.

For devices which have no termination of the Word Clock input, e.g. RME 
Hammerfall with Word Clock i/o or Alesis BRC, you can use an additional 
BNC-T piece to terminate the input. Plug the T piece with its center connec-
tor into the input of the receiving device. Then, connect the cable coming 
from the FORMAT CHANGER advanced to one of the lateral connectors, 
and the other connector of the BNC-T piece to a 75 

 resistor forming the 

BNC termination.

Basically, you should avoid »looping through« Word Clock leads by means 
of passive BNC-T pieces to preserve the signal quality, as level drops will be 
the result. If there is no other way to wire your set-up, please make sure 
that all Word Clock inputs (except for the last device in the chain) have 
their terminations disabled! In a serial Word Clock chain only the last clock 
input should have a termination! Never connect more than three devices in 
series to one output!

Additionally the condition of the 
packaging material and the device 
should be checked carefully. If there 

are any damages please refer to SAFETY 
INSTRUCTIONS, Initial Operation, and 
WARRANTY REGULATIONS.

!

Before installing the unit finally 
the section SAFETY INSTRUCTIONS 
located at the beginning of this 

manual should be read.

!

It is imperative that the lengths 
of all cables connected are largely 
the same, as this is the only way to 

ensure that all devices will be synchronized 
in phase (exception: cable tolerances).

Please make sure that the cable used has a 
resistance of 75 

, in compliance with the 

specifications! If a cable with a different 
resistance is used, a dramatic deterioration 
of the signal quality can be the result! In 
this case, the perfect synchronization of all 
devices involved could be impaired.

!

We recommend using high-grade cables 
with a good shielding for your clock signal 
leads, in particular, if you need to transmit 
Word Clock x 256 (so-called Super Clock) 
signals over greater distances. In any case, a 
length of max. 10 meters (approx. 30 feets) 
should never be exceeded!

11  

Summary of Contents for FORMAT CHANGER advanced

Page 1: ......

Page 2: ......

Page 3: ...0 Fax 030 746880 99 tecsupport mutec net de MUTEC GmbH assumes no liability for any incorrect information given in this manual Please note that all software hardware product names are registered trad...

Page 4: ......

Page 5: ...ring the AES EBU and S PDIF Interfaces 11 OPERATION Functional Areas Parameters 12 Operating the FORMAT CHANGER advanced 12 Parameters in the AUDIO INPUT Area 13 Parameters in the SYNC SOURCE Area 13...

Page 6: ......

Page 7: ...lly Addition ally the status of incoming SCMS copy bits original or 1st generation is signaled by LEDs In all operating modes constant jitter level and edge compensation is applied to all outgoing sig...

Page 8: ...8...

Page 9: ...or hard BYPASS the sampling rate converter to allow for the conversion of signal formats only 6 OUTPUT FREQ UENCY The third functional area controls the output sampling rate applied to the output cop...

Page 10: ...of the incoming digital audio signal as the Word Clock frequency The input output impedance is 75 the input impedance can be disabled internally 5 230 V 115 V This compartment houses the mains fuses w...

Page 11: ...ing resistor Most Word Clock inputs allow for enabling disabling the termination with a so called termination switch which may be located on the outside or inside of the device For devices which have...

Page 12: ...value when purchasing the cables Connect the optical S PDIF interface with the help of Toshiba TOSLINK compliant optical fiber cables Here you can use both plastic and glass fiber based cables When us...

Page 13: ...ey The SELECT key is used to select one of the three functional areas After selection of a different functional area the LED of the last function selected in this area starts flashing When you quit a...

Page 14: ...synchronization of the FORMAT CHANGER advanced The unit processes digital audio signals or S PDIF and or AES EBU blank frame signals which also involves the sampling rate converter When you select one...

Page 15: ...its and monitor their status As is generally known SCMS copy bits are exclusively defined in S PDIF data streams to prevent multiple copies of the digital audio material As a result copy bits can only...

Page 16: ...rror rate the FORMAT CHANGER advanced mutes all of its outputs ERROR MUTE LED lights up so as to protect your monitoring speakers or headphones from damage caused by erratic level fluctuations AUDIO S...

Page 17: ...nductor cold Ground lift of Word Clock Input Place the unit front panel towards you on a table and remove the steel plate cover after unscrewing the six screws holding it Locate the BNC jacks on the r...

Page 18: ...INPUT Interface 1 x XLR female transformer balanced input impedance 110 200mV 7 0V Format AES EBU3 1992 AES EBU11 1997 Resolution 16 24bits Lock range 32 0kHz to 108 0kHz S PDIF OPTICAL OUTPUT Interf...

Page 19: ...ration setting removing POWER SUPPLY Type Internal power supply Input voltage 115V 230V switchable 50 60Hz Power consumption max 12W removable power cord IEC320 C13 aligned SYSTEM UNIT COVER Cover siz...

Page 20: ......

Reviews: