MODEL 

PowerMust

 1008 Online LCD

 

PowerMust

 2016 Online 

LCD

 

PowerMust

 3024 Online 

LCD

 

CAPACITY* 

1000 VA / 800 W 

2000 VA / 1600 W 

3000 VA / 2400 W 

INPUT 

Low Line Transfer 

160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 % or 80 VAC / 70 VAC / 60 VAC / 50 VAC ± 5 %   

( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)   

Low Line Comeback 

  175 VAC ± 5 % or 85 VAC ± 5 %   

High Line Transfer 

  300 VAC ± 5 % or 150 VAC ± 5 %   

Voltage 
Range 

High Line Comeback 

  290 VAC ± 5 % or 145 VAC ± 5 %   

Frequency Range 

40Hz ~ 70 Hz 

Phase 

Single phase with ground 

Power Factor 

 0.99 @ 220-230 VAC or 110-120 VAC 

OUTPUT 

Output voltage 

208/220/230/240VAC or 110/115/120/127 VAC 

AC Voltage Regulation   

± 3% (Batt. Mode) 

Frequency Range   
(Synchronized Range) 

47 ~ 53 Hz or 57 ~ 63 Hz 

Frequency Range (Batt. Mode) 

50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 

Overload 

100%~110%: audible warning 

110%-130%: UPS shuts down in 30 seconds at battery mode or transfers to bypass 

mode when the utility is normal. 

>130%: UPS shuts down immediately at battery mode or transfer to bypass mode 

when the utility is normal. 

Current Crest Ratio 

3:1 

Harmonic Distortion 

 3 % THD (Linear Load)               

 6 % THD (Non-linear Load) 

 4 % THD (Linear Load)                                                                                                                                                                                             

 7 % THD (Non-linear Load) 

AC Mode to Batt. Mode 

Zero 

Transfer 
Time 

Inverter to Bypass 

4 ms (Typical) 

Waveform (Batt. Mode) 

Pure Sinewave 

EFFICIENCY 

AC Mode 

~ 85% 

~ 88% 

Battery Mode 

~ 83% 

BATTERY 

Battery Type 

12 V / 7 AH 

12 V / 7 AH 

12 V / 9 AH 

Numbers 

Recharge Time 

4 hours recover to 90% capacity (Typical) 

Charging Current   

1.0 A(max.) 

Standard 
Model 

Charging Voltage   

41.0 VDC ± 1%   

82.1 VDC ±1%   

Battery Type & 
Numbers 

Depending on the capacity of external batteries 

Charging Current   

4.0 A or 8.0 A(max.) 

Long-run 
Model 

Charging Voltage 

41.0 VDC ± 1%   

82.1 VDC ±1%   

PHYSICAL 

Dimension, D X W X H   

397 X 145 X 220 (mm) 

421 X 190 X 318 (mm) 

Tower 
Case 

Net Weight (kgs) 

13 

26 

13 

28 

13 

Dimension, D X W X H   

420x438x88[2U] (mm) 

580x438x133[3U] (mm) 

Rack 
Case 

Net Weight (kgs) 

16 

10 

29 

17 

31 

17 

ENVIRONMENT 

Operation Humidity 

20-90 % RH @ 0- 40°C (non-condensing) 

Noise Level 

Less than 45dBA @ 1 Meter 

MANAGEMENT 

Smart RS-232 or USB 

Supports Windows®2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix and MAC 

Optional SNMP 

Power management from SNMP manager and web browser 

* Derate capacity to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 208VAC. 

Summary of Contents for POWERMUST 1008 ONLINE LCD

Page 1: ...PowerMust 1008 Online LCD RM PowerMust 2016 Online LCD RM PowerMust 3024 Online LCD RM Online UPS User Manual EN...

Page 2: ...s 3 2 Installation and setup 4 2 1 Rear panel view 4 2 2 Setup the UPS 5 3 Operations 7 3 1 Button operation 7 3 2 LCD Panel 7 3 3 Audible Alarm 9 3 4 LCD display wordings index 9 3 5 UPS Setting 9 3...

Page 3: ...er them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only to an earthed sh...

Page 4: ...must be kept well away from the batteries Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the...

Page 5: ...rMust 3024 Online LCD Standard PowerMust 3024L Online LCD Long run 2 1 Rear panel view PowerMust 1008 L Online LCD PowerMust 2016 L Online LCD PowerMust 3024 L Online LCD PowerMust 1008 L Online LCD R...

Page 6: ...5 12 Output circuit breaker...

Page 7: ...or the wiring configuration a Remove the small cover of the terminal block b Suggest using AWG14 or 2 1mm2 power cords Suggest using WG12 10 or 3 3mm2 5 3mm2 power cords for NEMA type c Upon completio...

Page 8: ...tware to fully configure UPS shutdown You may insert provided CD into CD ROM to install the monitoring software If not please follow steps below to download and install monitoring software from the in...

Page 9: ...e UPS will be in standby mode under power normal or transfer to Bypass mode if the Bypass enable setting by pressing this button Confirm selection key Press this button to confirm selection in UPS set...

Page 10: ...6 50 51 75 and 76 100 Indicates overload Indicates the load or the UPS output is short circuit Programmable outlets information Indicates that programmable management outlets are working Mode operatio...

Page 11: ...reviation Display content Meaning ENA Enable DIS Disable ESC Escape HLS High loss LLS Low loss BAT Battery CF Converter EP EPO FA Fan TP Temperature CH Charger 3 5 UPS Setting There are three paramete...

Page 12: ...ency setting Interface Setting Parameter 2 3 Output frequency setting You may set the initial frequency on battery mode BAT 50 presents output frequency is 50Hz BAT 60 presents output frequency is 60H...

Page 13: ...240 VAC models 230 264 setting the high voltage point in parameter 3 from 230Vac to 264Vac For 110 115 120 127 VAC models 120 132 setting the high voltage point in parameter 3 from 120Vac to 132Vac L...

Page 14: ...ry mode When the input voltage is beyond the acceptable range or power failure and alarm is sounding every 4 second UPS will backup power from battery Bypass mode When input voltage is within acceptab...

Page 15: ...cond Battery is not connected Sounding every second Over Charge Sounding every second Site wiring fault Sounding every second EPO enable Sounding every second Fan Failure Sounding every second Over te...

Page 16: ...cted Check if all batteries are connected well Fault code is shown as 27 and the icon is lighting on LCD display and alarm is continuously sounding Battery voltage is too high or the charger is fault...

Page 17: ...p time is shorter than nominal value Batteries defect Contact your dealer to replace the battery The icon and the warning code flashing on LCD display and alarm is sounding every second Fan is locked...

Page 18: ...Harmonic Distortion 3 THD Linear Load 6 THD Non linear Load 4 THD Linear Load 7 THD Non linear Load AC Mode to Batt Mode Zero Transfer Time Inverter to Bypass 4 ms Typical Waveform Batt Mode Pure Sin...