background image

OPERATION

A300 

Instructions for Use.  Page 6 of 9

REMOTE CONTROL

The A300 features Infra Red remote con-
trol of volume, input selection and mute
functions via the supplied remote control
handset.  The Infra Red receiver is the
small red lens marked I.R.Receiver. situat-
ed on the front panel.  It is important to
ensure that when operating the remote con-
trol, the line-of-sight from the remote to
the infra red receiver is not obstructed.

Pressing the volume up or down buttons on
the remote handset will advance the
motorised volume control in the desired
direction.

Input selection can also be controlled with
the remote handset. 

The mute button on the remote handset
mutes the output.  To show the amplifier is
muted the red LED in the volume control
goes out.  Press the mute button again to
switch the mute off, the red led will light
again.

PREAMP OUTPUT

The A300 has a permanently active pre-
amp output situated on the back panel.
This provides extra flexibility for use in
multi-room or surround-sound systems etc.
This signal comes from the A300's internal
preamp and its output level is thus con-
trolled by the front panel volume control.

This output allows easy upgrading by pas-
sive bi-amping with a pair of X-A50s or
X-A200s.

To bi-amp (which requires bi-wireable
speakers) an extra pair of X-ponent ampli-
fiers is attached to this permanent preamp
output. 

The A300's built in power amps can then
for instance drive the left and right channel
tweeters whilst the X-A50s or X-A200s
drive the left and right channel bass units. 

Passive bi-amping in this way can give
noticeable gains in clarity, imaging and
bass weight. 

If you would like further details please
contact your dealer or Musical Fidelity
directly.

issue 3/13.07.2000

Summary of Contents for A300

Page 1: ... ideas and principles developed in the legendary XA1 Integrated amplifier but with subtle changes and improvements Aesthetically the A300 is a perfect match for the A3 CD player and the A3 FM Tuner Together they form one of the finest hi fi systems that you can own today Dust regularly with a soft duster or soft brush but be careful using cleaning or polishing agents they may harm the surface fini...

Page 2: ... red The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black If connecting to a BS1363 plug a 13 amp fuse must be used WARNING Radio Frequency Interference RFI This hi fi product has been tested to ensure that its operation will not be adversely affected by normal background levels of RFI It is possible that if this product is subjected...

Page 3: ...leaning or polishing agents they may harm the surface finish There are fuses in the A300 In the unlikely event that one blows take your unit to your audio dealer Do NOT try to replace the fuse yourself or you will invalidate the warranty The remote control enables you to activate the main functions of the amplifier from the comfort of your armchair The following should be noted when operating the ...

Page 4: ...tton and LED 8 AUX input select button and LED 9 SACD input select button and LED 10 TAPE input select button and LED 11 Tape monitor button and LED A300 back panel layout 12 RIGHT speaker output 13 Phono earth connection 14 MM MC selection switch 15 Phono input 16 CD input 17 Tuner input 18 AUX input 19 SACD input 20 TAPE input 21 TAPE RECORD output 22 PREAMP output 23 LEFT speaker output 24 IEC ...

Page 5: ...e volume control to minimum 4 Now you can switch on the power and carefully advance the volume to the level you want and enjoy the music CONNECTIONS All connections should be made with the power OFF The A300 has 1 phono input which can be used for either moving magnet MM or moving coil MC cartridges The A300 also has 5 line level inputs CD Tuner Aux SACD and Tape All line level inputs are electric...

Page 6: ...the mute button again to switch the mute off the red led will light again PREAMP OUTPUT The A300 has a permanently active pre amp output situated on the back panel This provides extra flexibility for use in multi room or surround sound systems etc This signal comes from the A300 s internal preamp and its output level is thus con trolled by the front panel volume control This output allows easy upg...

Page 7: ... the source selector button on the front panel The selected source will now be sent to the Tape Record output for recording by the attached tape machine You will also be able to hear the selected source through the loudspeakers Note you can adjust the listening level with the volume control without affecting the recording level OFF TAPE MONITORING In conjunction with a 3 head cassette deck off tap...

Page 8: ...s are connected correctly Remote control unit will not operate POWER switch set to OFF Set switch to ON Batteries not inserted in remote control unit Insert batteries Batteries flat Change batteries Remote control not pointed at IR receiver lens Ensure line of sight between remote control and IR receiver lens is not obstructed Range of remote control has dramatically reduced Batteries running out ...

Page 9: ...m S N Ratio line inputs 83dB A weighted Ref 1W 100dB A weighted Ref 150W S N Ratio MM 78dB A weighted Ref 1W 82dB A weighted Ref 150W S N Ratio MC 70dB A weighted Ref 1W 73dB A weighted Ref 150W Power consumption 600W Max Dimensions Amplifier 440 x 116 x 400mm W x H x D Height includes feet Depth includes terminals Power requirements 100 115 230V AC 50 60Hz Factory preset Weight 16 kg un boxed A30...