background image

Manual  

MIRO 

GSM 

 

33    

that time. In other words, the input signal is ignored during the set delay time. This prevents instable 

input signals, or input impulses that occur repeatedly, to send identical SMS messages several times. 

Time delays can be set between 0.1 seconds and 99.9 hours.  

 

 

Note 

It is recommended to activate the delay function (prevents the transmission of 

several SMS messages for the same event). 

 

6.4.5 Time-delayed Messages on Output OFF 

If an input changes its state from "HIGH" to "LOW", a delayed message can also be activated. The 

MIRO GSM sends the predefined message after the preset time elapses and provided the affected 

input is still "LOW". This prevents instable input signals, or input impulses that occur repeatedly, to 

send identical SMS messages several times. Time delays can be set between 0.1 seconds and 99.9 

hours.  

 

 

Note 

It is recommended to activate the delay function (prevents the transmission of 

several SMS messages for the same event). 

 

6.4.6 Analog Inputs (MIRO GSM ADI6 DO4R 24 VDC, Art. No. 52531) 

The 6 inputs can be individually configured as digital or analog inputs. For this purpose, each input 

must be defined explicitly as an analog or digital input. The analog inputs are designed for a 

standardized 0 to 10 VDC analog signal. The resolution here is 12.5 mV across the whole range. 

 

www.comoso.com

Summary of Contents for MIRO GSM

Page 1: ...Manual MIRO GSM Safety Description Installation Software Run Mode Configuration Remote Access Technical Data Accessories www comoso com...

Page 2: ...rt No 52530 MIRO GSM ADI6 DO4R 24 VDC Art No 52531 MIRO GSM DI6 DO4R 230 VAC Art No 52532 Version 1 3 Edition 11_11 EN Article Number 52536 Murrelektronik GmbH Falkenstrasse 3 D 71570 Oppenweiler Phon...

Page 3: ...ex cases we even provide direct onsite support The CSC supplies support tools It performs measurements for fieldbus systems such as Profibus DP DeviceNet CanOpen and AS interface as well as energy hea...

Page 4: ...5 3 2 Installation 15 3 2 1 Connecting the Inputs 16 3 2 2 Connecting the Outputs 16 3 3 TEST and RESET Buttons 17 4 Software 18 4 1 System Requirements 18 4 2 Software Installation 19 5 Run Mode 20 5...

Page 5: ...SM ADI6 DO4R 24 VDC Art No 52531 33 6 4 7 Scaling and Unit 34 6 4 8 Messages and Limit Definition 35 6 4 9 Message Delay 40 6 4 10 Message Block 41 6 5 Configuring the Outputs 41 6 5 1 General Informa...

Page 6: ...ely result in death or severe personal injury WARNING Possible danger Failure to observe this warning may possibly result in death or severe personal injury CAUTION Low risk hazard Failure to observe...

Page 7: ...related requirements of the system machine The products are designed for industrial use An industrial environment is defined as one in which loads are not connected directly to the public low voltage...

Page 8: ...echnical training Only Murrelektronik technical personnel are allowed to execute work on the hardware and software of our products provided they are devices not described in this manual WARNING Electr...

Page 9: ...mply with the regulations and customary standards when you perform the electrical installation of the device Installation must be performed by a competent person Note The card owner bears the sole res...

Page 10: ...essages In order to obtain an overview of the present state of all inputs and outputs of the installation the input and output states can be queried by SMS The relay outputs can be linked to a timer f...

Page 11: ...stallations of all types and many more Fig 1 Application examples 2 3 Short Instructions Note Installation requirements The MIRO GSM must be disconnected from the power source when it is installed 1 S...

Page 12: ...nload from www murrelektronik com 7 Connect the RS232 interface of your PC or notebook to the programming interface of the MIRO GSM Fig 4 Connecting a PC or notebook with RS232 interface Note If there...

Page 13: ...LED and GSM LED flash regularly at the rate of one second after approx 100 s 11 Write the configuration you generated to the MIRO GSM 12 Select a free COM port menu option Configuration Select Port T...

Page 14: ...s than the stub antenna Art No 52533 Note When selecting the antenna take the installation location into consideration The MIRO GSM Stub Antenna Art No 52533 is not suitable for integration in a switc...

Page 15: ...state The MIRO GSM is isolation protected and does not require grounding Connect the MIRO GSM according to the schematic diagram below 3 2 1 Connecting the Inputs Fig 8 Connecting the MIRO GSM DI6 DO...

Page 16: ...nds a test message is sent RESET button the left button when viewed from the front All relay outputs are reset when the button is pressed for longer than 15 s in its home position This means for the f...

Page 17: ...sk storage capacity requirement 40 MB Programming interface RS232 USB with USB RS232 interface converter Screen resolution Minimal 1024 x 768 Pixel Please note If the screen resolution is too low the...

Page 18: ...ograms for mobile phones eg Nokia Ovi Suite can occur compatibility problems with the MIRO GSM Configuration software In this cases please contact us The installation menu is available in different la...

Page 19: ...lashing Data are transmitted SMS Tab 1 GSM LED displays 5 1 2 State LED State Rate Repetition Meaning LED dark Device is not running Intermittent flashing Irregular Device is running up Brief flashing...

Page 20: ...res t 1s are registered and can trigger a last SMS alarm message depending on the mode setting before the device shuts down The device restarts automatically after the power supply is restored The reg...

Page 21: ...w shows the error codes and their meaning Code Meaning Cause Remedial Action 1 No credit Pre paid card empty Load SIM card 2 Time not set Time not set Set time manually using menu option Options Setti...

Page 22: ...to clear Replace SIM card in replay 1002 No SIM card SIM card missing or soiled Insert SIM card or clean SIM contacts Tab 3 Error codes and their meaning 5 4 State Request When the PC is connected to...

Page 23: ...ink For this you require the MIRO GSM Configuration Software See Chapter 7 Remote Maintenance which describes the requirements for connection set up and operation in more detail 6 2 Managing the Phone...

Page 24: ...aracters are recognized by the programming software and displayed in an error window The error characters must then be deleted The Name data field can sort the list alphabetically in ascending or desc...

Page 25: ...rd is protected by PIN code just as a regular cell phone For more information please refer to the supplement supplied with the SIM card It describes procedures such as how you can clear a blocked SIM...

Page 26: ...scanned several times The results of this search are displayed with a list of networks Click on Search to display the available networks Then select the required network The SMS service center number...

Page 27: ...s against unauthorized access Note Remote access can only be activated from a PC using the serial cable interface RS232 CAUTION Remote access can be deactivated by remote access The device can then no...

Page 28: ...ation in this case MIRO GSM appears at the start of the reply The states of the inputs and outputs are mapped in the SMS message as follows I 001001 inputs 1 to 6 0 OFF 1 ON O 0101 outputs 1 to 4 0 OF...

Page 29: ...message is sent to the pre assigned phone numbers at each start up switch on power restore The message text can be edited Message in case of power failure This message is sent to the pre assigned pho...

Page 30: ...nge from LOW to HIGH and the inverse a change from HIGH to LOW One or both events can be configured to activate a message A separate message text can be entered for each event If the confirmation func...

Page 31: ...an event message is processed in order of their appearance device internal Several different messages can therefore be triggered simultaneously For example the two events pump breakdown and overtemper...

Page 32: ...edefined message after the preset time elapses and provided the affected input is still LOW This prevents instable input signals or input impulses that occur repeatedly to send identical SMS messages...

Page 33: ...s displayed in the configuration window and is adapted continuously to the entered values The values entered can be displayed in various decimal formats The following display types are selectable d in...

Page 34: ...he thresholds 6 4 8 Messages and Limit Definition The upper and lower limits must be defined to permit the sending of messages These limiting values depend on the installation which is monitored Howev...

Page 35: ...lts in the minimum lower level lLevmin lLevmin MinValue R x 0 05 Values entered below this value are corrected automatically by the software Example MaxValue 600 m3 h corresponds to 10 V of the analog...

Page 36: ...er and Lower Levels The installation is again in normal state A message is only sent if it is activated by and if the state is occurs i e the upper limit or lower limit was exceeded The message text i...

Page 37: ...measured value sent The MIRO GSM monitors the analog measured value A message is sent if the difference is activated by and the difference exceeds a certain value The maximum value here is 50 of the r...

Page 38: ...essage text and the value No blank is inserted between the value and the unit Fig 26 Example for Periodical messages Requesting a Value The present value can be requested by SMS The message text is fr...

Page 39: ...tition simultaneously If the confirmation password is not activated the phone number identification is used as a security check and it is sufficient to send an empty SMS message to the MIRO GSM 6 4 9...

Page 40: ...text is freely definable The device only responds to precise wording i e the message switch command must have the precise text wording as entered Uppercase and lowercase characters are ignored but th...

Page 41: ...command to be sent by SMS Switching times can be set between 0 1 seconds and 99 9 hours When the output is switched off after the preset time elapses a message is sent to confirm this action If a swi...

Page 42: ...M In order to do this set up a link to the MIRO GSM data call to the MIRO GSM via the GSM modem using the MIRO GSM Configuration Software Changes on the MIRO GSM can now be made in the familiar enviro...

Page 43: ...remote access function from unauthorized access Note Remote maintenance must first be activated from a PC over a customary commercial serial cable connection RS232 CAUTION Remote access can be deacti...

Page 44: ...ed for the whole time that the call is set up between the modem and the MIRO GSM for calls to a device in another country roaming fees may also be charged For this reason the call should be interrupte...

Page 45: ...er AT command sets for the modem in use After selecting the modem type you require enter the PIN for the modem SIM card in the appropriate field Confirm your inputs by clicking on OK Fig 30 Connection...

Page 46: ...onnection Fig 34 Error message Connection failed When the connection is set up successfully you can start to work with the Configuration Software as usual as described in the previous sections Please...

Page 47: ...and the MIRO GSM remote access or via a serial cable link the device state can be requested for all inputs and outputs and for the present analog values Note If values or settings are modified over t...

Page 48: ...displayed in the state request by at the appropriate input The relevant unit and the entered maximum value are used for the display If the signal lies within the measuring range the measuring bars ar...

Page 49: ...responding output to switch the output 7 5 Selecting the Language 7 5 1 General Information The MIRO GSM Configuration Software has the capability of changing languages The program need not be restart...

Page 50: ...Art No 52530 D 71570 Oppenweiler Output 250V 10A UL US C LISTED Out 12 48 VDC MIRO GSM DI6 DO4R 24 VDC MIROGSM 19 88 90 11 44 4 5 8 Technical Data 8 1 Dimensional Layout Fig 40 MIRO GSM dimensional la...

Page 51: ...A Individuelle SMS Meldung f r jeden E A Individual SMS message for each I O Einfach konfigurierbar per Computersoftware Easy to configure with computer software Meldung bei Ausfall bzw Wiederkehr der...

Page 52: ...romaufnahme Standby current consumption in standby approx 15 mA at 24 V DC approx 25 mA at 12 V DC approx 10 mA at 230 V AC Leistungsaufnahme power consumption 4 2 W 8 VA 5 W Einschaltstromstoss inrus...

Page 53: ...Min Ansteuerdauer Input AC DC min control time input AC DC 200 ms Netzausfallsicherheit power failure protection 15 ms Ausgangskreis Output circuit Ausgang output 4 relay contact Kontaktart contact ty...

Page 54: ...H x W x D 80 x 90 x 59 5 mm Geh usewerkstoff housing material Noryl SE1 Lexan EXL9330 Anschluss connection Screw terminal 2 5 mm 0 5 Nm Pozidrive slot head Schutzklasse protection class IP20 Befestigu...

Page 55: ...33 MIRO GSM Stummelantenne Stub antenna Art No 52534 MIRO GSM Au enantenne mit 5 m Kabel Antenna with 5 m cable Art No 52535 MIRO GSM Service und Inbetriebnahme Kit Service and Start up Kit Art No 525...

Page 56: ...Overview of Devices and Phone Numbers Devices N MIRO GSM Device ID Device type A D PIN Password Phone Number 1 2 3 4 5 6 7 8 9 10 Modem N MIRO GSM Device ID Device type A D Pin Password Phone Numbers...

Page 57: ...documentation produced by Murrelektronik GmbH may be changed in parts or amended or copied and transferred to the customer s users as part of the customer s own technical documentation on paper or on...

Page 58: ...ler Phone 49 7191 47 0 Fax 49 7191 47 130 info murrelektronik com www murrelektronik com The information in this manual has been compiled with the utmost care Liability for the correctness completenes...

Reviews: