CE-05171N page 42 of 44
8.0 Glossary
A
An
na
allo
og
g IIn
np
pu
utt
Terminals A18 to A29 are analog inputs on the C3-1 Centurion main I/O module. Accepts
voltage signals within the range of (0 to 5) VDC or (4 to 20) mA and are compared to con-
troller set points or events.
B
Bo
oo
ott llo
oa
ad
de
err
Means by which the Centurion controller communicates with C3-3 Display and MConfigPro
to receive and transfer new or updated configurations and firmware; and ensure data and
configuration synchronization.
C
Co
on
nttrro
olllle
err S
Se
ett p
po
oiin
ntts
s User defines normal operating range for the controller to optimize the equipment. Set
points can also define some other threshold, exception or event that may require action.
Multiple set points are often applied to a process and they may be manipulated as needed
to meet changing conditions.
D
De
ea
ad
d b
ba
an
nd
d
The user set range at which input may fluctuate without the controller taking any action.
The range may be fixed or variable.
D
Diig
giitta
all IIn
np
pu
utt
Terminals 30 to 61 are the digital input channels. User selects whether digital input is nor-
mally open (N/O), or normally closed (N/C). Users may also associate these inputs with
transition times for indicating no-flow conditions on divider blocks.
E
Ev
ve
en
ntt
Defines the action required by the controller in response to any number of parameters.
Event actions range from simple alarm message to emergency shutdown (ESD).
M
Ma
ag
gn
ne
ettiic
c P
Piic
ck
k U
Up
p
Terminals 64 to 65 are for magnetic pick up.
M
Ma
ax
xiim
mu
um
m
Maximum of engineering applied scale to the Offset and Span.
M
Miin
niim
mu
um
m
Minimum of engineering applied scale to the Offset and Span.
N
No
o--F
Fllo
ow
w
Designed to protect against compressor or engine failures, the controller monitors the cycle
time of lubrication system cycles and if that cycle time falls under a user assigned value, the
controller will activate a defined associated action.
O
Offffs
se
ett
User defined value to correct for known variance in the raw data.
P
Pa
an
ne
ell R
Re
ea
ad
dy
y
In States, the first logical step in start up.
P
Pe
errm
miis
ss
siiv
ve
e
A process condition, (Digital Input or Analog Set point), that must be met in order for the
engine to start.
S
Siig
gn
na
all
An electrical quantity of voltage or current that is used to represent or signify some other
physical quantity.
S
Sp
pa
an
n
The difference between the full scale output and the offset as raw data.
S
Stta
arrtt D
De
ella
ay
y
A time delay function to prevent premature start up.
S
Stta
atte
e
Predefined parameter of logical steps needed to successfully start and maintain an engine.
T
Te
errm
miin
na
all E
Em
mu
ulla
atto
orr
Allows a user to modify the firmware to allow upload or download of a record to either the C3-3
display or the controller. Always download a configuration after a firmware change.
T
Th
he
errm
mo
oc
co
ou
up
plle
e
A device for measuring temperature consisting of two dissimilar metals of high purity for an
accurate temperature/voltage relationship. User defines whether the calibration is J or K.
Terminals 1 to 17 are for thermocouple inputs.