background image

FW Murphy – CANdrive installation and operation                                                                           00-02-0618   revision F   7

th

 January 2011   p2/4 

 

General Information (cont.) 

CDV100F 

front view 

CDV300R 

front view 

Rear view 

System connection 

Panel Installation 

CANdrive modules are surface-mounted with 4 x no.4 screws, fixing centre dimensions as 
shown. Select screw length according to panel thickness, ensuring a maximum of 13mm  
(½ inch) screw depth into the CANdrive fixing holes. 

Model CDV100F, with forward facing connector, is designed for surface mounting inside  
an enclosed panel. Model CDV300F, with 8 LED indicators and rearward facing connector,  
is designed for front-of-panel mounting: this module requires an additional 60 x 40mm  
(2.4 x 1.6 in.) panel cut-out for rear access to connector and switches. A CDV300F with 
optional gasket CDVG (fitted into a well behind the case rim) provides IP65 front-of-panel 
environmental sealing. 

Before installing, ensure that the final mounting location meets operating temperature and 
environmental sealing requirements, and allows access for: 

a) connection of the wiring harness 

b) 

configuration of DIP switches S1 to S5 (location as shown above right). Alternatively,  
set these switches before panel fixing – see Configuration section below for full details.

 

Dimensions 

mm (in.) 

Configuration 

DIP switches S1 to S5 allow OEM- or user-configuration of 
CANdrive operating options. Switch S6 is not used. CANdrive 
is supplied with all switches in the ON (up) position.  

Switch settings must be made as appropriate, according to 
the configuration table right. Adjustment of the switch 
positions must be made while CANdrive is powered down. 

 

 

Switch 
position 

 on (up) 

 off (down)

 

Options: 

S1

S2

S3

S4

S5  

Murphy temp. and pressure gauge 

Datcon temp. and 0 – 7 bar pressure gauges 

atcon temp. and 0 – 10 bar pressure gauges

VDO temp. and 0 – 5 bar pressure gauges 

VDO temp. and 0 – 10 bar pressure gauges 

CAN 120 Ohm terminating resistor in circuit 

CAN 120 Ohm terminating resistor removed 

12V DC ower supply 

24V DC power supply 

Pressure gauge compatibility table: pressure versus approximate equivalent sender resistance (Ohms) 

Pressure 

psi 

0  10 20 30 40 50 60 70 80 90 100 

110 

10 

130 140 

bar 0  0.7 1.4 2.1 2.8 3.4 4.1 4.8 5.5 6.2 6.9 7.6 8.3 9.0 9.7 

Murphy 

240 205 171 143 123 103  88  74  60  47  33 

 

 

 

 

Datcon 0 – 7 bar 

240 

195 

160 

140 

115 

100 

82 

68 

55 

43 

35 

 

 

 

 

Datcon 0 – 10 bar 

240 

215 

190 

168 

150 

135 

118 

107 

97 

87 

77 

67 

58 

50 

42 

VDO 0 – 5 bar 

10 

38 

61 

85 

110 

130 

155 

180 

 

 

 

 

 

 

 

VDO 0 –10 bar 

15 

30 

45 

60 

70 

81 

92 

103 

114 

125 

136 

148 

160 

170 

182 

Temperature gauge compatibility table: temperature versus approximate equivalent sender resistance (Ohms)

 

Temperature °C 40  50  60  70  80  90  100 110 120 130 140 

°F 104 122 140 158 176 194 212 230 248 266 284 

Murphy 

1029 680 460 321 227 164 120  89  74  52  40 

Datcon 

360  160  80  50  38    

VDO 

282.4 

190.0 

134.0 95.2 69.1 51.2 38.5 29.4 22.7 18.0 14.5 

 