FW Murphy – CANdrive installation and operation 00-02-0618 revision F 7
th
January 2011 p2/4
General Information (cont.)
CDV100F
front view
CDV300R
front view
Rear view
System connection
Panel Installation
CANdrive modules are surface-mounted with 4 x no.4 screws, fixing centre dimensions as
shown. Select screw length according to panel thickness, ensuring a maximum of 13mm
(½ inch) screw depth into the CANdrive fixing holes.
Model CDV100F, with forward facing connector, is designed for surface mounting inside
an enclosed panel. Model CDV300F, with 8 LED indicators and rearward facing connector,
is designed for front-of-panel mounting: this module requires an additional 60 x 40mm
(2.4 x 1.6 in.) panel cut-out for rear access to connector and switches. A CDV300F with
optional gasket CDVG (fitted into a well behind the case rim) provides IP65 front-of-panel
environmental sealing.
Before installing, ensure that the final mounting location meets operating temperature and
environmental sealing requirements, and allows access for:
a) connection of the wiring harness
b)
configuration of DIP switches S1 to S5 (location as shown above right). Alternatively,
set these switches before panel fixing – see Configuration section below for full details.
Dimensions
mm (in.)
Configuration
DIP switches S1 to S5 allow OEM- or user-configuration of
CANdrive operating options. Switch S6 is not used. CANdrive
is supplied with all switches in the ON (up) position.
Switch settings must be made as appropriate, according to
the configuration table right. Adjustment of the switch
positions must be made while CANdrive is powered down.
Switch
position
on (up)
off (down)
Options:
S1
S2
S3
S4
S5
Murphy temp. and pressure gauge
Datcon temp. and 0 – 7 bar pressure gauges
atcon temp. and 0 – 10 bar pressure gauges
VDO temp. and 0 – 5 bar pressure gauges
VDO temp. and 0 – 10 bar pressure gauges
CAN 120 Ohm terminating resistor in circuit
CAN 120 Ohm terminating resistor removed
12V DC ower supply
24V DC power supply
Pressure gauge compatibility table: pressure versus approximate equivalent sender resistance (Ohms)
Pressure
psi
0 10 20 30 40 50 60 70 80 90 100
110
10
130 140
bar 0 0.7 1.4 2.1 2.8 3.4 4.1 4.8 5.5 6.2 6.9 7.6 8.3 9.0 9.7
Murphy
240 205 171 143 123 103 88 74 60 47 33
Datcon 0 – 7 bar
240
195
160
140
115
100
82
68
55
43
35
Datcon 0 – 10 bar
240
215
190
168
150
135
118
107
97
87
77
67
58
50
42
VDO 0 – 5 bar
10
38
61
85
110
130
155
180
VDO 0 –10 bar
15
30
45
60
70
81
92
103
114
125
136
148
160
170
182
Temperature gauge compatibility table: temperature versus approximate equivalent sender resistance (Ohms)
Temperature °C 40 50 60 70 80 90 100 110 120 130 140
°F 104 122 140 158 176 194 212 230 248 266 284
Murphy
1029 680 460 321 227 164 120 89 74 52 40
Datcon
360 160 80 50 38
VDO
282.4
190.0