![Murdock BF2 Series Installation & Maintenance Instructions Manual Download Page 3](http://html.mh-extra.com/html/murdock/bf2-series/bf2-series_installation-and-maintenance-instructions-manual_1857649003.webp)
Page 3 of 13
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
7109-700-001
WATER COOLERS
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
Please visit
www.murdockmfg.com
for most current specifications.
3. Mark vertical (plumb) center line on the wall.
4. Use the frame as a template. Align notches in frame with vertical center line, with frame sitting on the deck
NOTE: FOUNTAINS SHOULD BE LEVEL.
5. Mark four mounting holes.
6. Install the four anchors (by others).
7. Remove top and channel, disconnect the PE tube from the fill tube.
8. Align mounting frame and mounting channels to the anchors (as shown) attach to wall with mounting
fasteners (by others).
NOTE: BEFORE PERFORMING STEP 9 IF STEP HAS BEEN FACTORY ASSEMBLED, GO ON TO STEP 11.
9.*In drinking fountain access compartment, remove the 1/4” push-in fitting from evap outlet and replace it with 1/4”
push-in tee fitting. Reconnect the PE tube from the cartridge valve assembly to top of tee. (See page 4)
*See insert on page 4, for special installation instructions when installing on bi-level drinking fountains.
NOTE: BEFORE PERFORMING STEP 10 REFER TO ELECTRICAL INSTALLATION STEP 1A AND 2.
10. Remove the 18” piece of insulation from the 1/4” OD 30” PE tube . Pass the end of the 30” PE tube through the
hole in the deck of the drinking fountain. Reinstall 18” piece of insulation on to the 30” PE tube, under basin.
Connect the 30” PE tube to the side of the previously installed tee fitting, from step 10. (See page 4)
11. Reconnect 24” PE to fill tube. Engage the left side of the bottle filler housing behind the mounting channels, then
stretch the housing over the right end of the mounting channels, make sure that the rubber trim on the housing is
touching the deck. Secure the housing to the top channel, with 10-32 truss head screws provided.
NOTE: BEFORE PERFORMING STEP 13 REFER TO ELECTRICAL INSTALLATION STEP 1B AND 2.
12. Install top with 8-32 round head screws provided.
13. Turn on the water supply stop, test unit and check for leaks, then reinstall access panel.
INSTALLATION INSTRUCTIONS CONTINUED:
Water Cooler
(shown for reference)
C
L
2
7
8
"
(73)
10
5
16
"
(262
)
Note: Housing not shown
for clarity
Ø
3
8
" (9.5) x 4 Mounting Anchors
(by others)
Bottle Filler Mounting
Frame
To Filler Spout
Mounting
Channel
From Evaporator
Out Tee Fitting
Mounting
Channel
Alignment
Notch
3"
(76)
3"
(76)
Valve Inlet
MCBF2 (Install/Maintenance Instructions)
Date:
04/03/18