Murdock BF2 Series Installation & Maintenance Instructions Manual Download Page 1

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

Date: 

04/03/18

 

 

BF2 Series

Bottle Filler, Sensor Operated

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 

 

 

 

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

LIMITED WARRANTY - UNITED STATES & CANADA

Murdock warrants that its products are free from defects in material or workmanship under normal use and 
service for a period of one year from date of original shipment or for 18 months after the date of shipment from the 
factory, whichever comes first. Murdock’s liability under this warranty shall be discharged solely by replacement 
or repair of defective material, provided Murdock is notified in writing within one year from date of shipment, 
F.O.B. Industry, California. 

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

LIMITED EXPORT WARRANTY - 

One year on parts only. 

COMPLIES 

WITH

Member of

MURDOCK

15125 Proctor Ave.

City of Industry, CA

91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

 

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

7109-700-001

www.murdockmfg.com

 WATER COOLERS

 

Summary of Contents for BF2 Series

Page 1: ...maged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement...

Page 2: ...debris before connecting to fixture Bottle filler is designed to provide trouble free drinking water unaffected by fixture connection tubing and fittings and not cause problems with taste odor color or sediment It is common for electrical equipment to be grounded to water lines either within a structure or away from it Because this fixture is intended to dispense water that has been lowered in tem...

Page 3: ...talling on bi level drinking fountains NOTE BEFORE PERFORMING STEP 10 REFER TO ELECTRICAL INSTALLATION STEP 1A AND 2 10 Remove the 18 piece of insulation from the 1 4 OD 30 PE tube Pass the end of the 30 PE tube through the hole in the deck of the drinking fountain Reinstall 18 piece of insulation on to the 30 PE tube under basin Connect the 30 PE tube to the side of the previously installed tee f...

Page 4: ...E Tube to solenoid valve inlet Cold water tube from evaporator Cut tube and Install tee INSERT DETAIL For Bi Level drinking fountain when mounting bottle filler on unit with no compressor only MCBF2 Install Maintenance Instructions Date 04 03 18 Solenoid valve outlet elbow with flow control Solenoid valve inlet fitting Hole in deck Y strainer Evaporator Evaporator inlet Evaporator outlet Push in t...

Page 5: ...65 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Please visit www murdockmfg com for most current specifications MCBF2 Install Maintenance Instructions RETRO FIT INSTALL FOR EXISTING WATER COOLER FIXTURE PRESSURIZED SINGLE UNIT PIPE INSTALLATION WITH GF BF OPTIONS ITEM PART NUMBER DESCRIPTION QTY 1 7012 055 000 FOAM INSULATION PIPE 3 8 ID x 1 4 THICK 5 5 2 2169 000 000 TUBING LLDPE...

Page 6: ... To re pipe a single non pressurized unit to pressurized you will have to move the water supply tubing around with NO additional tubing needed Before performing this task you MUST SHUT OFF THE WATER SUPPLY and disconnect all supply connections STEP 3 From the outlet of the cartridge assembly connect to the bubbler STEP 1 Starting with the supply line coming from the wall connect to the inlet of th...

Page 7: ...t is secure Tube should not come free from the fitting Water test the connection assembly prior to leaving the site to ensure there are no leaks 4 To disconnect the tube from the fitting ensure that the water supply is off Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting 1 Cut to fit length of PE tubin...

Page 8: ...atteries not included Note When the battery holder is connected the unit active 2 Connect the blue sensor wires to the solenoid valve wires See Page 4 START UP 1 Air within the bottle filler system or the structure supply pipping will cause an irregular spout outlet stream until purged out by incoming water Hold cup or similar object directly below filler spout is recommended when first activating...

Page 9: ...nts refilled bottles otherwise purchased Adjustable for Units with and without filters REPLACEMENT FILTER alert function Alert reset when filter is replaced Description Illuminated LCD display counts bottles and has a filter replacement alert function Bottle Counting Function The software applies a flow volume of approximately 16 9 fl oz volume in standard size plastic water bottle to each bottle ...

Page 10: ...IMPLEMENTS With this reset button you are able to indicate whether or not the unit has a filter or does not have a filter The reset button will also take away the REPLACE FILTER alert once the filter has been replaced Systems With or Without Filter Depress the Reset Mode selection button for 6 Seconds the number of seconds will count up on the display At the end of the 6 seconds FLTR YES or FLTR N...

Page 11: ...hone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Please visit www murdockmfg com for most current specifications BOTTLE FILLER BOTTLE COUNTER CONNECTIONS MCBF2 Install Maintenance Instructions Date 04 03 18 SOLENOID CONNECTION POWER SUPPLY CONNECTION BLACK CABLES SENSOR CONNECTION BLACK RED CABLES SENSOR CONNECTION TRANSFORMER SOLENOID VALVE BOTTLE COUNT DISPLAY SENS...

Page 12: ...from the main supply can get trapped in the screen along with installation materials such as pipe dope and flux The screen should be cleaned and checked on a regular basis and replace if needed e Flow control in solenoid valve outlet elbow clogged remove clean f The water cooler may also develop a freezing condition in which the water will become frozen inside the evaporator coil This indicates a ...

Page 13: ...8 32 SOCKET CAP BTN HD SCREW 18 7014 008 001 CHANNEL AND VALVE ASSEMBLY 5 2563 380 001 SENSOR ASSEMBLY 19 7013 008 199 BOTTLE FILLER CHANNEL 6 1895 123 000 1 4 X 3 8 O D TUBE UNION PUSH IN 20 7014 010 199 TRIM RIGHT SIDE 7 7013 016 001 AA 6 PACK BATTERY HOLDER 21 7014 009 199 TRIM LEFT SIDE 8 7013 015 001 9V PLUG IN TRANSFORMER 22 7013 014 199 NANO SENSOR BRACKET 9 7013 210 001 Y STRAINER BTL FILL...