background image

 

 

A152-VR

Page 10 of 11

Date: 

10/29/2020

7021-022-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

CARTRIDGE VALVE PARTS BREAKDOWN

3

2

1

5

4

2. Clean Strainer as needed using clean water.

CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE 

Note: Use the Universal Maintenance Tool to perform the following:

1. Strainer Plug must be removed before Cartridge replacement and Strainer maintenance (no need to turn the 

water off at the Angle Stop). Some residual water will drainduring Plug removal.

3. Cartridge Replacement - insert diamond end of the Universal Tool into Pushbutton, rotate 90 degrees and pull 

firmly to remove the Button. Remove Cartridge Retaining Nut . Remove and replace Cartridge. When replacing 
Cartridge, be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body.

 NOTE: STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.

 

Universal Maintenance Tool

-Cartridge Retaining Nut

-Button Removal

-Strainer Plug
-Removal of P.E. Tubing from
 Push-in Fittings

6

ITEM #

PART NUMBER DESCRIPTION

1

7003-095-000

Valve Body Sub Assembly

2

7000-060-000

Valve Cartridge

3

7000-052-000

Retaining Nut

4

7003-864-000

Strainer, Auto Stop

5

7003-097-001

Strainer Cap

6

7003-194-199

Maintenance Tool

 

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

Summary of Contents for A152-VR Series

Page 1: ...perly maintained after the water has been introduced into the water cooler or drinking fountain or Murdock s limited warranty is void NOTES TO INSTALLER 1 Please leave this documentation with the owner of the fixture when finished 2 Please read this entire booklet before beginning the installation 3 Check your installation for compliance with plumbing electrical and other applicable codes Murdock ...

Page 2: ...e and local codes A152 VR Page 2 of 11 Date 10 29 2020 7021 022 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Notes 1 Standard Bi Level rough ins shown For RBL Reverse Bi Level Mounting Frame rough ins opposite CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T ...

Page 3: ...eral Notes 1 Dimension indicated with is for 33 drinking fountain discharge height if discharge height differs adjust accordingly 2 Standard Bi Level rough ins shown For RBL Reverse Bi Level Mounting Frame rough ins opposite CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS SUPPLIED WALL MOUNTING PLATE 1 1 1 4 OD WASTE OUTLET 2 3 8 NC...

Page 4: ...S 3 REFERENCE DISCHARGE HEIGHT REQUIREMENTS FOR YOUR MODEL AND FACILITY TO DETERMINE CORRECT HEIGHT AT FINISHED FLOOR AFF AFTER POSITIONING PLATE CORRECTLY FIX PLATE TO WALL USING APPROPRIATE INSTALLER PROVIDED ANCHORING HARDWARE 4 MAKE UP APPROPRIATE SUPPLY 5 AND WASTE 6 ROUGHS THROUGH MOUNTING PLATE OPENINGS LOCATE 5 16 THREADED STUDS MOUNTING HARDWARE AND THREAD STUDS 7 THRU PLATE SO THAT A MIN...

Page 5: ...octor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of WATER TUBING CONNECTIONS CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS PE Tubing ...

Page 6: ...ther components 5 Completely flush water supply lines of all foreign debris before connecting to the fixture 3 Install the four threaded studs into the Wall Mounting Frame 2 Hang trim panel on mounting frame Note The included 1 brackets do not get used with this installation and the plastic spacers are typically not required and can be discarded 1 Water Supply Service Stop Valve and Water Connecti...

Page 7: ...OM THE TOP SIDES AND BOTTOM USING INSTALLER PROVIDED HARDWARE 3 C INSTALL TRIM PANEL 4 BY ENGAGING OVER JOGGLE 5 ON TOP OF FRAME 1 SEE ENGAGEMENT DETAIL D ASSEMBLY OF DRINKING FOUNTAINS THROUGH TRIM PANEL 4 INTO MOUNTING FRAME 1 HELPS SECURE TRIM PANEL 4 INTO ONTO WALL 4 5 3 2 1 2 3 3 2 4 ENGAGEMENT DETAIL NOTE TRIM PANEL FIXTURE MOUNTING POINTS 6 DIFFER TO MATCH MODEL REFERENCED BUT DOES NOT CHAN...

Page 8: ...HE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be s...

Page 9: ...to make colder and counterclockwise to make warmer c Check for twists or kinks in outlet tubing h No power to transformer connections loose or wires cut A152 VR Page 9 of 11 Date 10 29 2020 7021 022 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 2 If there are stubborn spots or if you wish to treat...

Page 10: ...rt diamond end of the Universal Tool into Pushbutton rotate 90 degrees and pull firmly to remove the Button Remove Cartridge Retaining Nut Remove and replace Cartridge When replacing Cartridge be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW Universal Maintenance Tool Cartridge Retaining Nut Button...

Page 11: ...r 9 7003 193 000 Spring Pushbutton Return 2 0116 016 000 10 32 x 3 8 Phillips Truss Head Screw 10 7003 196 199 Pushbutton Chrome 3 7000 006 000 Flat Drain Adapter Gasket 11 7003 197 199 Escutcheon Chrome 4 7000 015 000 1 1 4 OD P Trap 12 0161 062 000 6 32 x 1 2 Phillips Flat Head Screw 5 0152 010 000 10 32 x 1 Hex Flat Head Screw 13 0124 055 000 8 x 3 4 Phillips Round Head Screw 6A 7000 012 001 St...