IMPORTANT:

 1.  Water Supply Service Stop Valve and Water Connections to be supplied by others in accordance with local 

codes.

 2.  Waste is 1-1/4” Outer Diameter. Drinking Fountain water inlet is 3/8” Outer Diameter copper tube. Bottle 

Filler water inlet is 3/8” Outer Diameter copper tube. Water line by others.

 3.  Completely flush supply lines of all foreign debris before connecting to fixture. Optional Water Filter (WF1), is 

available should any problems with taste, odor, color, or sediment arise from the water supply.

4.  All burrs must be removed from outside of cut tubes before inserting into strainer or other components.

 5. 

Per UPC 609.10-All building water supply systems in which quick acting valves are installed shall be 
provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the 
valve. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing 
devices shall be installed as close as possible to the quick closing valve.

PRIOR TO INSTALLATION:

1. Read all installation instructions carefully, before proceeding.

5. Completely flush water supply lines of all foreign debris, before connecting to the fixture.

8. After thoroughly flushing the 3/8” outer diameter supply line, connect water supply to the 3-way divider 

assembly. From the 3-way divider assembly, connect to drinking fountain bubbler.

4. Remove the drinking fountain top by taking out the drain screw and lifting at the front while pulling forward. 

Disconnect bubbler tube. Set top aside in a safe place where it will not be damaged. Place the screw in a 
secure location where it will not be lost.

2. Hang trim panel on mounting frame. Note: The included 1” brackets do not get used with this installation and 

the plastic spacers are typically not required and can be discarded.

3. 

If water flow requires adjustment, insert a slotted narrow blade screwdriver in the hole centered on the 

underside of the fixture in the knee clearance area up to the flow regulator. Turning clockwise will increase 
flow and turning counterclockwise will decrease flow.

2. Carefully remove all fixture components  from packaging, preventing scratching or damage. Inspect fixture and 

all parts from damages and all parts that are bolted on.

7. Make-up 1-1/4” outer diameter waste connection.

DRINKING FOUNTAIN START UP:

1. Insert mounting frame into the rough-in block out and secure using 1/4”-20 UNC mounting hardware (Provided 

by Others).

3. Provide mounting surface, adequate to support the fixture and loads on the fixture.

6. Assemble P-trap to drain adapter and then assemble to unit with Phillips head screws.

2. 

Air within the drinking fountain system or the structure supply piping will cause an irregular bubbler outlet 

stream until purged out by incoming water. Covering the bubbler with a clean cup (or similar object) is 
recommended when first activating drinking fountain to prevent excessive splashing. Depress front push pad 
until steady water stream is achieved.

1. 

Before connecting power supply, but after thoroughly flushing the supply line, turn on building water supply 

and check all connections for leaks.

4. 

Recheck all water connections with water flowing through system.

4. Provide rough-ins as shown on the roughing-in and dimensional drawing, including water supply, drain pipe 

and gravel drain well. (See rough-in details)

9. Place drain gasket on drain adapter. Reconnect bubbler tube. Reassemble top to unit by engaging back clip 

and securing with screw.

DRINKING FOUNTAIN INSTALLATION:

3. Install the four threaded studs into the Wall Mounting Frame

5. Slide Fixture over studs and secure with nuts and washers.

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

Summary of Contents for A131-VR Series

Page 1: ...any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each unit and disregard or non compliance with these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job site during construction and must be properly maintained after ...

Page 2: ...ensions as required to comply with federal state and local codes A131 VR Page 2 of 12 New 10 28 2020 7021 012 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of GENERAL NOTES 1 ALL DIMENSION ARE IN INCHES MM 2 DIMENSION SHOWN ARE FOR RECOMMENDED ADULT HEIGHT ADJUST VERTICAL DIMENSIONS AS NECESSARY TO C...

Page 3: ...tor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of SUPPLIED WALL MOUNTING PLATE 1 1 1 4 OD WASTE OUTLET 2 3 8 NCT SUPPLY INLET 3 CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS 2 4 3 2 1 21 2 3 8 271 4 295 8 28 33 ...

Page 4: ...HALK LINE TO LOCATE BOTTOM MOUNTING HOLES 3 REFERENCE DISCHARGE HEIGHT REQUIREMENTS FOR YOUR MODEL AND FACILITY TO DETERMINE CORRECT HEIGHT AT FINISHED FLOOR AFF AFTER POSITIONING PLATE CORRECTLY FIX PLATE TO WALL USING APPROPRIATE INSTALLER PROVIDED ANCHORING HARDWARE 4 MAKE UP APPROPRIATE SUPPLY 5 AND WASTE 6 ROUGHS THROUGH MOUNTING PLATE OPENINGS LOCATE 5 16 THREADED STUDS MOUNTING HARDWARE AND...

Page 5: ...enue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of WATER TUBING CONNECTIONS PE Tubing Mounting Plate CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS ...

Page 6: ...te The included 1 brackets do not get used with this installation and the plastic spacers are typically not required and can be discarded 3 If water flow requires adjustment insert a slotted narrow blade screwdriver in the hole centered on the underside of the fixture in the knee clearance area up to the flow regulator Turning clockwise will increase flow and turning counterclockwise will decrease...

Page 7: ...TOM FLANGES 2 ARE AGAINST FINISHED WALL SECURE TO WALL FROM THE TOP SIDES AND BOTTOM USING INSTALLER PROVIDED HARDWARE 3 C INSTALL TRIM PANEL 4 BY ENGAGING OVER JOGGLE 5 ON TOP OF FRAME 1 SEE ENGAGEMENT DETAIL D ASSEMBLY OF DRINKING FOUNTAIN THROUGH TRIM PANEL 4 INTO MOUNTING FRAME 1 HELPS SECURE TRIM PANEL 4 INTO ONTO WALL 4 5 ENGAGEMENT DETAIL NOTE TRIM PANEL FIXTURE MOUNTING POINTS 6 DIFFER TO ...

Page 8: ...HE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be s...

Page 9: ...et assembly to bottom of fixture but do not remove Move complete valve bracket assembly further back from the front push pad and tighten to lock in place A131 VR Page 9 of 12 New 10 28 2020 7021 012 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 2 If there are stubborn spots or if you wish to treat...

Page 10: ...ool into Pushbutton rotate 90 degrees and pull firmly to remove the Button Remove Cartridge Retaining Nut Remove and replace Cartridge When replacing Cartridge be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body CARTRIDGE REPLACEMENT STRAINER MAINTENANCE 2 Clean Strainer as needed using clean water Universal Maintenance Tool Button Removal Cartridge Retain...

Page 11: ...hown is the 18 long unit however the parts are the same for the 14 long unit ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION 1 7000 005 199 Drain Adapter 9 7003 193 000 Spring Pushbutton Return 2 0116 016 000 10 32 x 3 8 Phillips Truss Head Screw 10 7003 196 199 Pushbutton Chrome 3 7000 006 000 Flat Drain Adapter Gasket 11 7003 197 199 Escutcheon Chrome 4 7000 015 000 1 1 4 OD P Trap 12 ...

Page 12: ...16 016 000 Phillips Truss Head Screw 13 2562 373 001 9V DC Sensor Assembly 5 7000 005 199 Drain Adapter 14 7001 202 199 Sensor Spacer 6 7000 021 000 Y Strainer 15 7000 015 000 1 1 4 OD P Trap 7 7000 067 001 Flow Adjustment Valve Sensor Bracket 16 0711 410 001 9V DC Plug In Transformer 8 7000 050 001 Valve Assembly 17 7001 200 001 Solenoid Valve Assembly w Mounting Bracket 12 11 9 10 7 8 2A 4 3 5 6...

Reviews: