background image

 

Operation Manual MK200 

 

Table of content

 

1.

 

Important user information ................................................................................... 3

 

1.1 Intended use of equipment ................................................................................... 3

 

1.2 Warranty and obligations ...................................................................................... 3

 

1.2.1 Note ................................................................................................................... 3

 

1.2.2 Safety ................................................................................................................ 3

 

2.

 

Installation ............................................................................................................ 4

 

2.1 Electrical connection ............................................................................................. 4

 

2.2 Operation .............................................................................................................. 5

 

2.3 Disposal ................................................................................................................ 5

 

3.

 

Placement of dehumidifier .................................................................................... 5

 

3.1 Operation of dehumidifier ..................................................................................... 5

 

3.2 Automatic shut off and float switch ....................................................................... 6

 

3.3 Drainage of water ................................................................................................. 6

 

3.3.1 Using the hose: .................................................................................................. 6

 

3.3.2 Without hose, directly to a drain outlet: .............................................................. 6

 

3.4 Humidity Control ................................................................................................... 7

 

3.5 Air filter ................................................................................................................. 7

 

3.6 Automatic defrosting ............................................................................................. 7

 

3.7 Fan ....................................................................................................................... 7

 

4.

 

Operation principle ............................................................................................... 8

 

4.1 Maintenance and cleaning .................................................................................... 8

 

4.2 Trouble shooting ................................................................................................... 9

 

5.

 

Technical data ansd warranty ............................................................................ 10

 

5.1 Technical data .................................................................................................... 10

 

5.2 

 

Warranty ......................................................................................................... 10

 

6.

 

Wiring diagram ................................................................................................... 11

 

7.

 

Explosion drawing .............................................................................................. 12

 

8.

 

Spare parts list ................................................................................................... 13

 

9.

 

CE Certificate ..................................................................................................... 14

 

 
 

 

 

 

Summary of Contents for MK200

Page 1: ...Operation Manual Dehumidifier MK200 Valid from 15 10 2018 ...

Page 2: ...Operation of dehumidifier 5 3 2 Automatic shut off and float switch 6 3 3 Drainage of water 6 3 3 1 Using the hose 6 3 3 2 Without hose directly to a drain outlet 6 3 4 Humidity Control 7 3 5 Air filter 7 3 6 Automatic defrosting 7 3 7 Fan 7 4 Operation principle 8 4 1 Maintenance and cleaning 8 4 2 Trouble shooting 9 5 Technical data ansd warranty 10 5 1 Technical data 10 5 2 Warranty 10 6 Wiring...

Page 3: ...he full warranty period is serviced and maintained by a qualified Munters engineer or Munters approved engineer Access to specific and calibrated test equipment is necessary The service and maintenance must be documented for the warranty to be valid Always contact Munters for service or repair Operating faults can occur if the unit is maintained insufficiently or incorrectly 1 2 1 Note The content...

Page 4: ...iance The appliance shall be installed operated and stored in a room with a floor area larger than 4m Obey the installation instruction supplied with the appliance Always be careful when you move the appliance because it is heavy Always wear safety gloves Make sure the air can circulate around the appliance Wait at least 4 hours before connecting the appliance to the power supply This is to allow ...

Page 5: ...umidifier MK200 dehumidifiers are easy to move around all you need to have is a power source for 220 240V but bear in mind the following The dehumidifier should not be placed near radiators or other heat sources or exposed to direct sunlight as it will reduce performance It is beneficial to use a radiator or heating fan to keep the temperature above 2 C The dehumidifier should stand at least 25cm ...

Page 6: ...anted 5 Push the water tank home The float should now be in the tankr instead of being stuck behind it 6 Reconnect the dehumidifier to the power supply 3 3 Drainage of water The dehumidifier is fitted with a hose connection By attaching a hose to the dehumidifier the condensed water can be drained directly away 3 3 1 Using the hose 1 Disconnect the dehumidifier from the power source and remove the...

Page 7: ...es the capacity of the dehumidifier and cleanses the air further Please refer to the separate filter leaflet for installation and maintenance instructions 3 6 Automatic defrosting MK200 dehumidifiers are fitted with a control unit which ensures that the cooling coils are defrosted automatically when needed The control shuts down the compressor which causes the cooling of the coils to stop The fan ...

Page 8: ...intenance free Filter cleaning As the dehumidifying capacity is decreasing with a dirty filter it should be cleaned regularly This could be done either by using a vacuum cleaner washing with a mild detergent Replacement filters are available from your Munters Service Dehumidifier cleaning The front grill could be cleaned using a rap or vacuum cleaner If the inside of the unit is dirty it has to be...

Page 9: ...Defrost cycle can take 35 minutes Check that there is no thick coating of ice forming on the cooling coils High noise level Increase distance between dehumidifier and surrounding objects Cooling coils may be touching each other and cause a ringing noise due to vibration Disconnect dehumidifier from power supply and separate coils Ice formation on cooling coils Remove air filter at rear of dehumidi...

Page 10: ...ls Defrost automatically Electric control built in humidistat Display indication full water tank Condensate drain into water tank alternatively directly through drain connection 5 2 Warranty Warranty period is 24 months after delivery if nothing else has been agreed upon and documented This warranty is limited to free of charge replacements and delivery to delivery address of parts which are fault...

Page 11: ...Operation Manual MK200 11 6 Wiring diagram ...

Page 12: ...Operation Manual MK200 12 7 Explosion drawing ...

Page 13: ...nser 9073700410 12 Drip tray 9073700411 13 Fan motor 9073700212 14 Float switch mounting clip 9073700412 15 Water tank 9073700413 16 Compressor 9073700414 17 Micro switch 9073700415 18 Fan blade 9073700233 19 Component carrier 9073700416 20 Carrier lid 9073700417 21 Circuit board sensor 9073700418 22 Adapter 9073700419 23 Knob 9073700420 24 Handle 9073700421 25 Adaptor hose Euro design 9073700422 ...

Page 14: ...midifier type MK 200 are in conformity with the following directives 2014 35 EU Low Voltage Directive 2014 30 EU EMC Directive 2011 65 EU RoHS Directive and are manufactured in conformity with the following standards EN60335 1 2010 Fifth edition EN60335 2 40 2002 A1 2005 A2 2005 EN62233 2008 EN55014 2 1997 Munters GmbH Hamburg 15 10 2018 ______________ Place and date P Kruetzmann Head of order han...

Reviews: