11
Universal Fancoil DC
MUC-W9 series
Model
Power supply
V/Ph/Hz
220-240/1/50
Air flow (H/M/L)
m
3
/h
580/435/310
580/430/300
780/550/380
780/560/390
CFM
341/256/182
341/253/176
459/324/224
459/329/229
External static pressure Pa
0
Cooling
Sensible Capacity(H/M/L)
kW
2.58/2.08/1.53
2.83/2.29/1.67
3.21/2.52/1.88
3.54/2.77/2.02
Capacity (H/M/L) kW
3.41/2.81/2.16
3.80/3.11/2.36
4.25/3.43/2.67
4.73/3.82/2.85
Water flow rate
m
3
/h
0.58/0.48/0.37
0.65/0.53/0.40
0.73/0.59/0.46
0.81/0.65/0.49
Water pressure drop
kPa
33.4/24.0/15.0
36.5/25.3/15.0
53.5/35.8/24.1
53.0/35.9/21.2
Heating
Capacity (H/M/L) kW
3.70/3.02/2.29
3.90/3.13/2.43
4.64/3.65/2.77
5.12/3.98/2.96
Water flow rate
m
3
/h
0.63/0.52/0.39
0.67/0.54/0.40
0.80/0.63/0.47
0.88/0.68/0.51
Water pressure drop kPa
34.2/23.8/14.5
35.6/24.7/13.9
53.6/36.4/22.0
52.0/35.6/20.0
Power input (H/M/L)
W
27/18/11 30/18/12 50/26/15 52/28/15
Rated current A
0.26
0.28
0.49 0.51
Sound pressure level
(H/M/L)
dB(A)
39/32/24 39/32/24 46/39/30 46/39/30
Sound power level
(H/M/L)
dB(A)
52/45/37 52/45/37 59/52/43 59/52/43
Fan motor
Type
Low noise DC fan motor
Quantity
1 1 1 1
Fan
Type Centrifugal,
forward-curved Blades
Quantity
2 2 2 2
Coil
Row
3 4 3 4
Max. working pressure
MPa
1.6 1.6 1.6 1.6
Diameter mm
Φ7.94
Φ7.94
Φ7.94
Φ7.94
Body
Net dimensions (W×D×H)
mm
495×211×1240
495×211×1240
495×211×1240
495×211×1240
Packing size (W×D×H) mm
595×300×1345
595×300×1345
595×300×1345
595×300×1345
Net weight kg
25.5
26.5
25.5
26.5
Gross weight
kg
32.5
33.5
32.5
33.5
Water inlet/outlet pipe
inch
G3/4
G3/4 G3/4 G3/4
Drain pipe mm
ODΦ18.5
ODΦ18.5
ODΦ18.5
ODΦ18.5
Notes:
1. H: High fan speed; M: Medium fan speed; L: Low fan speed.
2. Cooling conditions: Entering water 7
ć
, leaving water 12
ć
, Entering air temperature 27
ć
DB/19
ć
WB.
3. Heating conditions: Entering water 45
ć
, leaving water 40
ć
, Entering air temperature 20
ć
DB/15
ć
WB.
4. Sound power level is tested in a reverberation chamber.
5. Sound pressure level is tested in a semi-anechoic room.
(none)
(none)
(none)
(none)
Summary of Contents for MUC-05-W9/CE
Page 18: ...17 NC Noise Curve Universal Fancoil DC MUC W9 series none none...
Page 19: ...18 Universal Fancoil DC MUC W9 series none none...
Page 20: ...19 Universal Fancoil DC MUC W9 series none none...
Page 21: ...20 Universal Fancoil DC MUC W9 series MUC 05 W9 MUC 08 W9...
Page 22: ...21 Universal Fancoil DC MUC W9 series MUC 11 W9 MUC 16 W9...
Page 23: ...22 Universal Fancoil DC MUC W9 series MUC 19 W9 MUC 24 W9...
Page 24: ...23 Universal Fancoil DC MUC W9 series none none...
Page 25: ...24 Universal Fancoil DC MUC W9 series none none...
Page 26: ...25 Universal Fancoil DC MUC W9 series none none...
Page 27: ...26 Universal Fancoil DC MUC W9 series none none...
Page 28: ...27 Universal Fancoil DC MUC W9 series none none...
Page 29: ...28 Universal Fancoil DC MUC W9 series none none...