CLOCK display
Usually display the clock set currently. Press the button CLOCK for 4 seconds,
the HOUR part will flash, press button
and to adjust HOUR. Press the button
CLOCK again, the minute part flash, press button or to adjust MINUTE.
After clock set or clock operation, it must press CONFIRM to complete the set.
TIMER ON/OFF display:
Display ON at the state of TIMER ON adjustment or after only set the TIMER
ON; Display OFF at the state of TIMER OFF adjustment or after only set the
TIMER OFF; Display ON/OFF if simulta neously set the mode of TIMER ON and
TIMER OFF.
Temperature display area:
Usually display the set temperature. Press the buttons of and to set tempera
ture, at the mode of FAN, there is no figure display in the area.
5. INSTALLATION METHOD
5-Core Shield Cable,the length
is decided by installation
Wire Joint, 5p
Infraed Pipe
Indoor Unit
RUN
+5V
Indoor Unit Switch Board
Wire Controller
Connection mothod and the principle
diagram show as follow
When the air conditioner needs installing the wire controller, an additional 5-terminal is
needed to install in indoor unit, fasten a infrared emission (fasten with glue), connect the
anode and the cathode respectively to A and B on the end, then connect the +5V GND
and RUN respectively to C D and E on the end
Installation interpretation:
Economical operation display:
Press ECONOMICAL to display econo mical operation, if press ECONOMICAL
again then the display disappears
Lock display Press LOCK to display the icon of LOCK. Press the button
again then the icon of LOCK disappears. In the mode of LOCK, all the buttons
are invalid except for LOCK button.