19
DESCRIPTION AND OPERATING INSTRUCTIONS
Do not operate the air conditioner for long periods with
the air flow direction set downward in cooling or
dehumidifying mode. Otherwise, condensation may
occur on the surface of the horizontal louver causing
moisture to drop on to the floor or on furnishings.
Do not move the horizontal louver manually unless it is
necessary. Always use the remote controller.
When the air conditioner is started immediately after it
was stopped, the horizontal louver might not move for
approximately 10 seconds.
Open angle of the horizontal louver should not be set
too small, as COOLING or HEATING performance may
be impaired due to too restricted air flow area.
Do not operate unit with horizontal louver in closed
position.
When the air conditioner is connected to power (initial
power), the horizontal louver may generate a sound for
10 seconds, this is a normal operation.
CAUTION
Range
For some models, the vertical louver can only be adjusted
manually. Move the deflector rod manually to adjust the air
flow in the direction you prefer.
IMPORTANT
:Do not put your fingers into the panel of
blower and suction side.
The high-speed fan inside may
cause danger.
AUTO operation
When you set the air conditioner in AUTO mode,
it will automatically select cooling, heating(cooling
/heating models only), or fan only operation
depending on what temperature you have selected
and the room temperature.
The air conditioner will control room temperature
automatically round the temperature point set by
you.
If the AUTO mode is uncomfortable, you can
select desired conditions manually.
SLEEP operation
When you push SLEEP button on remote controller
during cooling, heating(cooling only type without),
or AUTO operation , the air conditioner will
automatically increase (cooling) or decrease
(heating) 1
℃
per hour.
The set temperature will be steady 2 hours later.
And the air conditioner will be timer off in 7 hours.
The fan speed will be automatically controlled.
This feature can maintain the most comfortable
temperature and save more energy for you.
DRYING operation
The fan speed will be automatically controlled
under dry operation.
During the dry operation, if the room temperature
O
is lower than 10 C, the compressor stops operation
and restarts until the room temperature is above
O
12 C.
1 hour
1 hour
Set
Temperature
Cooling
1
℃
1
℃
Heating
SLEEP operation
1
℃
1
℃
1 hour
1 hour
Set
Temperature
SLEEP operation
7 hours timer off
7 hours timer off
How the air conditioner w ork s