Muncie
Power
Products
INSTALLATION
INSTRUCTIONS
ELECTRONIC
OVERSPEED SWITCH
EOS-110 &
EOS-111
Page 1: ...Muncie Power Products INSTALLATION INSTRUCTIONS ELECTRONIC OVERSPEED SWITCH EOS 110 EOS 111...
Page 2: ...put RPM signal is lost or not properly sensed via the yellow wire no output power will be available via the green wire for the solenoid or clutch This feature is beneficial in obtaining the proper sig...
Page 3: ...the EOS 110 Digital voltmeter Crimping stripping pliers Screw driver 06 Electric drill with 3 16 bit 3 8 socket and drive Standard pliers Hot air gun optional Parts included for installation of EOS 1...
Page 4: ...ne Green Power Output From EOS 110 Normally open output Connect this line to solenoid or clutch coil Yellow RPM Input To EOS 110 Connect this line to alternator R terminal tachometer signal or connect...
Page 5: ...ternators CS Series Output rating CS 121 61 74 amp CS 130 85 100 105 amp CS 144 108 120 amp The P terminal is connected to the stator Connect yellow EOS 110 lead to this terminal 10 SI Series Passenge...
Page 6: ...ontact the dealer for assistance Prestolite Leece Neville Alternators are very common on many makes of small diesel and large gas engines In the absence of a separate terminal attach to the right hand...
Page 7: ...ide if any test fails EOS 110 Speed Adjustment Procedure Using a Voltmeter 1 The EOS 110 has test jacks to allow adjustment by use of a voltmeter The test jack voltages will be in the 0 6 VDC range Yo...
Page 8: ...disengage adjustment screw adjust the voltmeter so that the display shows your desired disengagement speed based on the relationship that 1 0 VDC 1000 RPM Example a disengage speed of 1800 RPM will sh...
Page 9: ...ottom of the EOS 110 2 Using the 6 screws from the kit screw the plate into place so that the seal gasket is facing in Field Replacement of the EOS 100 The EOS 110 can be used to replace the EOS 100 U...
Page 10: ...riefly run engine between 1200 1500 RPM See pg 5 this manu al or contact dealer Check crimp and connection of yellow wire Voltage at TACH jack does not increase with engine speed Poor or loose connect...
Page 11: ...rom which the unit was purchased for twelve months from the date of purchase Units may not be returned unless specifically authorized in writing by the Muncie Division from which the unit was purchase...
Page 12: ...oducts Muncie Power Products Inc General Offices and Distribution Center P O Box 548 Muncie IN 47308 0548 765 284 7721 FAX 765 284 6991 E mail info munciepower com Web site http www munciepower com Dr...