S-Register:
S0
Usage:
S0=n; S0?
Function:
Number of Rings Until Answer
Unit:
1 ring
Range:
n=0-255 (0-255 rings)
Default:
1 (1 ring)
Description:
S0 sets the number of rings the TA waits for before it answers and begins its connect
sequence. S0=0 turns off the ability to automatically answer a call. S0=1 causes the
TA to automatically answer after 1 ring. Note that if the S0 value is set too high, the
calling device may time out before the TA answers the call. For auto-answer, S0 must
have a non-zero value, DTR must be high (&Dn command), and the TA must be
offline.
S-Register:
S1
Usage:
S1?
Function:
Ring Count
Unit:
1 ring
Range:
n=0-255 (0-255 rings)
Default:
0 (0 rings)
Description:
S1 counts the number of rings that have occurred, up to a maximum of 255. It is a
read-only register and is seldom, if ever, used in typical operation. If you set S1 to a
value other than its default value of zero, or if the value is increasing with rings, this
new value remains stored in S1 for eight seconds after the last ring is counted, after
which time the value reverts to zero.
S-Register:
S2
Usage:
S2=n; S2?
Function:
Escape Character
Unit:
Decimal ASCII code
Range:
n=0-127
Default:
43 (+)
Description:
S2 specifies the character used by the TA to escape from data mode and return to
command mode.
S-Register:
S3
Usage:
S3=n; S3?
Function:
Carriage Return Character
Unit:
Decimal ASCII code
Range:
n=0-127
Default:
13 (^M)
Description:
S3 specifies the character used by the TA to indicate the end of a command line.
S-Register:
S4
Usage:
S4=n; S4?
Function:
Line Feed Character
Unit:
Decimal ASCII code
Range:
n=0-127
Default:
10 (^J)
Description:
S4 specifies the character used by the TA to indicate the end of a status message.
S-Register:
S5
Usage:
S5=n; S5?
Function:
Backspace Character
Unit:
Decimal ASCII code
Range:
n=0-32, 127
Default:
8 (^H)
Description:
S5 specifies the character used by the TA to delete the previous character in the
command line.
Summary of Contents for RASFinder RF300E
Page 5: ...Remote Access Device Chapter 1 Introduction and Description ...
Page 11: ...Remote Access Device Chapter 2 Installation ...
Page 14: ...RASFinder RF300E RF310E User Guide RF300E RF310E 14 ...
Page 15: ...Remote Access Device Chapter 3 Software Loading and Configuration ...
Page 35: ...Remote Access Device Chapter 4 RASFinder Software ...
Page 72: ...RASFinder RF300E RF310E User Guide RF300E RF310E 72 ...
Page 73: ...Remote Access Device Chapter 5 Client Setup ...
Page 90: ...RASFinder RF300E RF310E User Guide RF300E RF310E 90 ...
Page 91: ...Remote Access Device Chapter 6 RAS Dial Out Redirector ...
Page 99: ...Remote Access Device Chapter 7 Remote Configuration and Management ...
Page 108: ...RASFinder RF300E RF310E User Guide RF300E RF310E 108 ...
Page 109: ...Remote Access Device Chapter 8 Service Warranty and Tech Support ...
Page 113: ...Remote Access Device Appendixes ...