31
Chapter 4 - AT Commands, S-Registers and Result Codes
MTA128ST-USB
Switch Configuration Commands
Use the following commands to select your network switch type (e.g., EuroISDN Net3)
and to specify other information required to make an ISDN connection.
Command: %A97=n
Function:
Dialing Method
Values:
n = 0 or 1
Default:
%A97=0 (En bloc)
Description: Standardized ISDN signaling protocols such as DSS1, DSS2, and SS7
support sending complete indication, (a signal that no more digits follow).
Adding this signal to a telephone number often is impractical. Therefore,
many private networks send the number of a called party using a procedure
called overlap sending, where no sending complete indication is sent.
Computer users can automatically add the sending complete indication to a
telephone number by choosing the en bloc method of sending, which results
in faster call setup. Use the %A97= command to select between the two
methods.
%A97=0
En bloc sending during call SETUP
%A97=1
Overlap sending during call SETUP
Command: !C0=n
Function:
Network Switch Type
Values:
n = 0, 1, 2, 4, 5, or 6
Default:
!C0=2 (Net3)
Description: Use the !C0= command to select one of the six network switch types
supported by the TA. Factory default setting is !C0=2 (NET3).
!C0=0
AT&T 5ESS
!C0=1
Northern Telecom DMS-100
!C0=2
EuroISDN NET3
!C0=4
INS64
!C0=5
US NI-1
!C0=6
VN4
Command: !C6=n
Function:
Data SPID
Values:
n = 0–20 character string
Default:
null string
Description: Use !C6= to specify the data service profile identifier (SPID) that the ISDN
service provider assigned at subscription time. The data SPID string can
have up to 20 characters. This command is not used if the switch type is set
to NET3.
Note: For DMS-100 switches, any ASCII character except the underline (_)
character is valid. For NI-1 and AT&T switches, only the digits 0–9 are valid.
Command: *!C6=n
Function:
Voice SPID
Values:
n = 0- to 20 character string
Default:
null string
Description: Use *!C6= to specify the voice service profile identifier (SPID) that the ISDN
service provider assigned at subscription time. The voice SPID string can
have up to 20 characters. It is not used if the switch type is set to NET3.
Note: For DMS-100 switches, any ASCII character except the underline (_)
character is valid. For NI-1 and AT&T switches, only the digits 0–9 are valid.
Summary of Contents for MultiModemISDN MTA128ST-USB
Page 1: ...Model MTA128ST USB External ISDN Terminal Adapter User Guide...
Page 5: ...Chapter 1 Introduction and Description...
Page 10: ...10 MultiModemISDN User Guide MTA128ST USB...
Page 11: ...Chapter 2 Hardware Installation...
Page 17: ...Chapter 3 Software Installation and Configuration...
Page 26: ...26 MultiModemISDN User Guide MTA128ST USB...
Page 27: ...Chapter 4 AT Commands S Registers and Result Codes...
Page 61: ...Chapter 5 Troubleshooting...
Page 68: ...68 MultiModemISDN User Guide MTA128ST USB...
Page 69: ...Chapter 6 Warranty Service and Technical Support...
Page 75: ...Appendixes...
Page 84: ...84 MTA128ST USB User Guide MTA128ST USB...
Page 85: ...Glossary...