PPP General
PPP
Enable/disable PPP. The default is
Disable
. When enabled, the unit functions as a router.
PPP must be disabled to access the integrated cellular modem directly using telnet port
5000. If PPP is enabled, you cannot access the integrated cellular modem.
Dial-on-Demand:
Enable/disable Dial-on-Demand. The default is
Disable
. If you disable it, the router will
always stay connected unless the Idle Time Out expires. When Dial-on-Demand
is enabled,
use the ‘Wakeup on Call’ settings under the PPP menu to configure the settings for re-
establishment of the connection.
Idle Time Out:
Set the amount of idle time that will pass before the router will timeout. The default is 180
seconds. If the time expires, the PPP connection to the internet will disconnect. Any IP
packets from the LAN side or IP traffic from the wireless side will reset this timer and prevent
the connection from dropping.
Connect Time Out:
Set the number of seconds to wait for a connection while in receive mode before timing out.
Dialing Max Retries:
Enter the number of dialing retries allowed. The default is zero, which means an infinite
number is allowed. Range 0 to 100.
Authentication
Authentication Type:
Set the authentication protocol type that will negotiate with the remote peer: pap/chap/pap-
chap. Default is pap-chap.
User Name:
Enter the User Name with which the remote peer will authenticate. Default is ipmodule. You
can leave this field blank, if desired. User Name is limited to 60 characters.
Password:
Enter the Password with which the remote peer will authenticate. Default is ipmodule. You
can leave this field blank, if desired. Password is limited to 60 characters.
ICMP Keep Alive Check
Keep Alive Check:
Enable/disable Keep Alive Check. The default is
Disable
. This is used to periodically check
that the internet connection is up. If it is not, the router will try to reconnect.
Keep Alive Type:
Select ICMP or TCP (the protocol type for Keep Alive).
Host Name:
Enter the Host Name or IP Address for Keep Alive Check. No default.
TCP Port:
Enter the TCP Port number to connect with the TCP server.
Interval:
Set the number of seconds for Keep Alive Check. Default is 30 seconds.
ICMP Count:
Set the number of ICMP Keep Alive Checks to be sent to the specified host. Default is 10.
Modem Configuration
(Refer to the Customer Activation Notices included with the product for proper information to
enter).
Dial Number:
Set the dial number to be dialed. Default is NULL. The dial number is
*99***1#
.
Dial Prefix:
Set the modem dial prefix. The default is ATDT.
Connect String:
Set the modem Connect String. The default is CONNECT.
APN:
Enter the APN (Access Point Name). The APN is assigned by your wireless service
provider.
Init String 1-4:
Configure the modem init strings. You can set up to 4 modem initialization strings.
Submit Button
Click the
Submit
button to save these settings.
Note:
You must click
Save and Restart
once you have completed and submitted all the screens on which you have made
changes.
Note:
The MTCBA-H-EN2 is shipped with command AT^SLED=1 entered at Init String 2. If the MTCBA-H-EN2 is set back to
factory default using the pushbutton on the back of the chassis, this command will need to be reentered and saved as Init
String 2 for the LS LED to display properly.