MultiModemISI Hybrid Series, ISIHP-2S/2U/4S/4U/4SD
115
Terminal Adapter AT Commands & S-Registers
Serial Port Configuration Commands
Use the following commands to control the interaction between the TA and
the computer connected to it.
En
Command Mode Echo
Values: n = 0 or 1
Default:
E1
(Echo on)
When you enter commands, the TA echoes the characters back to the
computer or terminal where they appear on the monitor. This
command
turns this feature on and off.
E0
Echo off
E1
Echo on
L5
and
L6
List Active Profile
Values: n = 5 or 6
Default: none
Lists current operating parameters of the TA. This information is useful
when changing communications software or when changing default settings.
ATL5
lists AT command parameters, and
ATL6
lists values currently stored
in the S-Registers.
L8
Lists Low Level ISDN Status
Qn
Enable/Disable Result Codes
Values: n = 0, 1, or 2
Default:
Q0
(Enable result codes)
Controls whether the TA sends result codes to the computer. (Use the
V
command to select the format of the result codes.)
Q0
Enable result codes.
Q1
Disable result codes (quiet mode) for
applications such as computer-controlled
auto dialing.
Sr=n
Set S-Register
Values: r = 0, 25, 7, 8, 10, 25, 32, 34, 50, 52-57, 75-
77, 80; n varies
Default: None
All manuals and user guides at all-guides.com