DEVICE ADMINISTRATION
68
MultiConnect
®
rCell 100 MTR-LTE User Guide
9.
In the
Email Address
field, enter the email address of the person responsible for the device. Typically this
is the administrator. This field may be left blank.
10.
Click
Generate
. Wait until the certificate is generated. You may have to reboot to complete the
operation.
11.
To save your changes, click
Save and Restart
.
Uploading a New Certificate
To upload a new certificate:
1.
Go to
Administration > Certificate Management
. The Certificate window displays the details of the
certificate that is currently used.
2.
Click
Upload
to open
Upload Certificate
window.
3.
Click
Choose File
to select a valid certificate to be uploaded.
4.
Click
Save
. Wait until the file is uploaded.
5.
To save your changes, click
Save and Restart
.
Setting up the Remote Management
To modify DeviceHQ
TM
automatic update settings, go to options under
Auto-Update Settings
and refer to
Managing Your Device Remotely.
1.
Go to
Administration > Remote Management > Remote Server
. To allow the device to connect to the
Remote Management Server, check
Enabled
.
2.
If you want the device to use a secure connection, check
SSL Enabled
. This feature might be supported in
a future release.
3.
The
Server Name
field is pre-populated with the address of the Remote Management Server.
4.
The
Server Port
field is pre-populated with the port the Remote Management Server listens on. You likely
do not need to change this.
5.
In the
Account Key
field, type the account key received from the Remote Management administrator.
The device is not allowed to connect to the Remote Management Server without a valid account key.
6.
Click
Submit
.
7.
To save your changes, click
Save and Restart
.
Managing Your Device Remotely
DeviceHQ
TM
can monitor devices, reboot devices, and perform remote software and configuration updates.
To configure your device to use DeviceHQ
TM
:
1.
Go to
Administration > Remote Management
and check
Enabled
. See other options under Setting up the
Remote Server.
2.
Go to options under
Auto-Update Settings
.
3.
To define how often the device connects to DeviceHQ
TM
to check in and request any pending updates, set
the
Check-In Interval
field to the desired number of minutes between 1-10080 (1 minute to 1 week).
Note:
Your device must connect to DeviceHQ
TM
every 4 hours at a minimum. If you set the check-in interval
to less than 4 hours, your change is ignored.