![Multitech MultiConnect rCell 100 Series User Manual Download Page 40](http://html.mh-extra.com/html/multitech/multiconnect-rcell-100-series/multiconnect-rcell-100-series_user-manual_1855987040.webp)
CHAPTER 7 SETTING UP WIRELESS FEATURES
IP Pipe in TCP/UDP Server mode
1.
In the
IP Pipe
group, from the Mode drop-down list, select
SERVER
.
2.
From the
Protocol
drop-down list, select the desired protocol, either TCP or UDP.
3.
In the
Server Port
field, type the desired port value in the range 1 to 65535.
4.
From the
Connection Termination
drop-down list, select a disconnect method for the IP pipe. Options
are:
■
Always Connected
■
Sequence A sequence of characters received from the Bluetooth side used to disconnect the IP pipe.
■
Timeout The IP pipe connection disconnects if the configured timer expires with no data sent or received.
To configure the IP Pipe in TCP/UDP Client mode:
1.
In the
IP Pipe
group, from the Mode drop-down list, select
CLIENT
.
2.
From the
Protocol
drop-down list, select the desired protocol, either TCP or UDP.
3.
In the
Server IP Address
field, type the address of the far-end TCP-UDP server.
4.
In the
Server Port
field, type the port value used by the far-end TCP/UDP Server.
5.
In case the primary server is unavailable, in the
Secondary IP Address
field and in the
Secondary Port
field, type the IP address and port number, respectively, of the alternate TCP/UDP server.
6.
From the
Connection Activation
drop-down list, select a connection method. Options are:
■
Always On
■
CR Three carriage returns must be received from the Bluetooth side before TCP/UDP connection is
established to the remote server.
7.
From the
Connection Termination
drop-down list select a disconnect method for the IP pipe. Options are:
■
Always Connected
■
Sequence A sequence of characters received from the Bluetooth side used to disconnect the IP pipe
■
Timeout The IP pipe connection disconnects if the configured timer expires with no data sent or received
8.
Click
Submit
.
After you are finished with configuring the Bluetooth feature, Save and Restart.
The router immediately connects to the local bluetooth device. If successful the Status field displays Connected. If
IP Pipe is configured for SERVER, the IP connection is initiated by the far-end TCP/UDP client.
If Mode is set to Client, the router initiates connections for the far-end TCP/UDP server based on the configured
Connection Activation conditions are met.