SPECIFICATIONS AND HARDWARE INFORMATION
12
MultiConnect
®
Conduit
TM
AP MTCAP User Guide for Europe
Resetting the Device
You need:
A pin, paperclip, or similar thin object that can fit into the reset hole
To reset the device:
1.
Find the hole labeled RESET. The reset button is recessed into the case.
2.
Use the pin to press and release the RESET button as follows:
Reset options:
To reboot, press RESET for less than 3 seconds.
To reboot and restore user-defined defaults (if previously set), press RESET for 3 to 29
seconds.
To reboot, restore factory settings, and erase user-defined defaults, press RESET for 30
seconds or longer.
The device restarts in commissioning mode. The system automatically removes all user
accounts.
Enter a new username and password to create your new administrative account. (Refer to
User Accounts
for more details on username and password requirements.)
Note:
The device reboots when restoring settings.
Power Measurements
MTCAP-LEU1-868-001L
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source
when determining product load.
Maximum Power:
The continuous current during maximum data rate with the radio transmitter at
maximum power.
Tx Pulse:
The average peak current during a GSM850 transmission burst period or HSDPA/LTE
connection. The transmission burst duration for GSM850 can vary, depending on what transmission
scheme is being deployed (GPRS Class 8, Class 10, GSM, etc.).
Inrush Charge:
The total inrush charge at power on.
Radio Protocol
Live Connection
(SIM Installed) No
Data
Cellular Call
Box
Connection,
No Data
Average
Measured Current
at Maximum
Power
TX Pulse (AVG)
Amplitude Current
for GSM850 or
Peak Current for
HSDPA/LTE
Total Inrush
Charge Measured
in Millicoulomb
5.0 Volts
EGSM 900 MHz
204 mA
212 mA
690 mA
2.0 Amps
1.35 mC
LTE
NA
266 mA
1.15 Amps
1.3 Amps
1.35 mC