UTC - 2202G

POWER SUPPLY

 TEMPERATURE CONTROLLER

Supply voltage

Power consumption
(VA RATING)

Approx  4VA @ 230V AC MAX

100 to 270V AC, 50-60Hz

Input Types

Resolution

Indication

Input  

Range

0 to 600°C 

0.0 to 400.0°C 

0 to 1200°C 

-50 to 400°C 

0.0 to 500.0°C 

-50.0 to 400.0°C 

J.1 

PT-100 

K.1 

PT.1 

J,K,PT-100 = 1°C

Class 0.5

J.1,K.1,PT.1 = 0.1°C

Display

Heating

Size 

Keys

Cooling

Panel Cutout

Upper: 4 digit, 7 segment, 0.70” 

1) PID control with Auto-Tuning

1) BL.TP (Blower Time Proportional)

Lower: 4 digit, 7 segment, 0.50” 

2) (TP) Time Proportional

2) ON-OFF control

72 (H) x 72 (W) x 85 (D) mm

SET, INC, DEC, ENT

68 (H) x 68 (W) mm

TECHNICAL SPECIFICATION

INPUT SPECIFICATION: 

DISPLAY AND KEYS:

DIMENSION:

CONTROL METHOD:

TERMINAL CONNECTION

PV

 = Process value

SV

 = Set Value

Accuracy

3) ON-OFF control

8

9

3-Wire RTD

2-Wire RTD

Thermocouple

Install jumper 
when using 
2 Wire RTD

+

Sensor Input

8

9

10

72

85

68

68

3

MECHANICAL INSTALLATION

72

Outline Dimension (mm)

Panel Cutout 
Dimension (mm)

SET

  ENT

UTC 2202G

R1

R2

TUNE

PV

SV

ºC

200

.

O

200

.

O

8

9

10

ENVIRONMENT CONDITION:

Relative Humidity

Protection Level
(AS Per Request)

 Operating Temp.

0°C to 55°C

UP to 95% RH 
(non-condensing)

IP-65 (Front side) As per IS/IEC
60529 : 2001

   Display Color

:

   Upper : White Or Red
   Lower : Green 

OUTPUT SPECIFICATION :

Relay

Relay Type

Rating

2 nos.

1 C/O , (NO-C-NC)

10A, 230V AC / 28 V DC

Relay Output

SSR Drive Output

Output Signal

12V DC, 30mA DC
(ON-OFF Condition)

Relay 1 Parallel to SSR

TC

+

RTD

-

!

L

N

1

2

3

4

5

6

7

-

+

O/P

S.S.R

 RELAY-1

100  
270V AC
    

~

 

50/60 Hz
4VA

NC

NO

C

8

9

10

11

12

13

14

Made in India

www.multispanindia.com

 RELAY-2

NC

NO

C

Summary of Contents for UTC-2200G

Page 1: ...TROL METHOD TERMINAL CONNECTION PV Process value SV Set Value Accuracy 3 ON OFF control 8 9 3 Wire RTD 2 Wire RTD Thermocouple Install jumper when using 2 Wire RTD Sensor Input 8 9 10 72 85 68 68 3 ME...

Page 2: ...or to installation and operation of the unit WARNING Risk of electric shock SAFETY PRECAUTION All safety related codifications symbols and instructions that appear in this operating manual or on the e...

Page 3: ...e Out Band Alarm Heating Mode Low Alarm Cooling Mode Outband Alarm Alarming Mode OFF Mode Yes No Save Set 2 Individual to Set 1 Set 2 Reletive to Set 1 Second Hour Minute Factory Setting ALM2 S2MD R1D...

Page 4: ...t power on NO In case of power supply failure soak time counting will be restarted at next power on Soak time memory MEMO END SAVE NO In case of soak time end if user apply SAVE in configuration then...

Page 5: ...alarm alarm BASIC CONFIGURATION Password is 73 If CTR1 PID CONTROL PARAMETER SETTING Press key to Save Exit If CTR 2 BL TP If CTR1 TP Password is 37 Press key to Save Exit R2MD OFF S2MD INDI 0 to 999...

Page 6: ...TP Selected If ON OFF Selected If LOW HIGH Ab L Select If PID TP Selected If ON OFF Selected Heat Heat Case 2 If PID TP Selected Heat Cool Case 3 If IN B AB O OT B Select If ON OFF Selected If ON OFF...

Page 7: ...If LOW HIGH Ab L Select If IN B AB O OT B Select If LOW HIGH Ab L Select If IN B AB O OT B Select If PID TP Selected If ON OFF Selected Heat Alarm Case 4 Cool Cool Case 5 Cool Alarm Case 6 Page 7...

Page 8: ...Auto tuning function automatically computes and sets the Proportional band Pb Integral time It Derivative time dt and cycle time as per process characteristics Tuning LED will turn ON during Auto Tuni...

Reviews: