SRE
Check the sensor and the input wiring. If problem still exists,
replace the sensor. And still if problem is not solved yet by the
user, then please contact company person
Sensor connection is reversed
FACTORY SETTING
PARAMETER RANGE
FACTORY SETTING
PARAMETER
IT
CT
Offset
PB
DT
MR
Hysteresis
Delay time
VALUES
300
15 Sec
20.0°C
75
0°C
0°C
3°C
6 sec
SR.
2
4
6
1
3
5
7
8
ENT
SET
Press key for 3 sec to
enter password
Set Point
Press k
e
y
Password Message
PB
IT
Sr.
1
2
0.0 to 999.9
0.0 to 999.9
0 to 9999
0 to 9999
Parameter
Range for J, K, PT100
Range for J.1,K.1,PT.1
SET
Basic Configuration
Press k
e
y
To ENTER BASIC
CONFIGURATION
SETTING, ENTER “73”
Message
Password
Input
Relay Mode
Control Action
Hysterisis
Delay Time
Set Low Limit
Set High Limit
CORRECTIVE ACTION:
34
fCst
234
YES
Press + key
for 3 sec
yes
: Press key to apply factory set
values as shown in table.
: Press key to escape
from factory setting.
ENT
ENT
no
no
ERROR
OPEN
MEANING
When an error has occurred the display indicates error codes
as given below.
Sensor is not connected or
ERROR DISPLAY
Set Point Setting
Process Value
Set Value
PARAMETER SETTING
Over range condition or
sensor break
DT
CT
MR
OffSet
Hysteresis
Delay Time
3
4
5
6
7
8
0 to 9999
0 to 9999
4 to 99 Sec
4 to 99 Sec
1 to 999 Sec
1 to 999 Sec
-9°C to +9°C
-9.0°C to +9.0°C
-20°C to +20°C
-20.0°C to +20.0°C
1°C to 100°C
0.1°C to 100.0°C
ENT
Offset
Press key to save & exit