DCA400SSI GENERATOR • OPERATION AND PARTS MANUAL — REV. #2 (11/03/08) — PAGE 31
INSPECTION/SETUP
Refueling Procedure:
Level Tanks
1.
— Make sure fuel cells are level with the
ground. Failure to do so will cause fuel to spill from the
tank before reaching full capacity (Figure 29).
Only Fill on Level Ground
Figure 29.
WARNING
Diesel fuel
and its vapors are dangerous
to your health and the surrounding
environment. Avoid skin contact and/or
inhaling fumes.
CAUTION
ALWAYS
place trailer on firm level ground before
refueling to prevent spilling and maximize the amount
of fuel that can be pumped into the tank.
NOTICE
ONLY
use
#2 diesel fuel
when refueling.
Open cabinet doors on the “right side” of the generator
2.
(from generator control panel position). Remove fuel
cap and fi ll tank (Figure 30).
Fueling the Generator
Figure 30.
NEVER overfi ll fuel tank
3.
— It is important to read the
fuel gauge when fi lling trailer fuel tank.
DO NOT
wait
for fuel to rise in fi ller neck (Figure 31).
Full Fuel Tank
Figure 31.
Fuel Expansion
Figure 32.
CAUTION
DO NOT OVERFILL
fuel system. Leave room for fuel
expansion. Fuel expands when heated (Figure 32).
Summary of Contents for Power WHISPERWATT DCA400SSI
Page 21: ...DCA400SSI GENERATOR OPERATION AND PARTS MANUAL REV 2 11 03 08 PAGE 21 NOTES ...
Page 53: ...DCA400SSI GENERATOR OPERATION AND PARTS MANUAL REV 2 11 03 08 PAGE 53 NOTES ...
Page 62: ...PAGE 62 DCA400SSI GENERATOR OPERATION AND PARTS MANUAL REV 2 11 03 08 CONTROL BOX ASSY ...
Page 74: ...PAGE 74 DCA400SSI GENERATOR OPERATION AND PARTS MANUAL REV 2 11 03 08 BATTERY ASSY ...
Page 76: ...PAGE 76 DCA400SSI GENERATOR OPERATION AND PARTS MANUAL REV 2 11 03 08 MUFFLER ASSY ...
Page 90: ...PAGE 90 DCA400SSI GENERATOR OPERATION AND PARTS MANUAL REV 2 11 03 08 RUBBER SEALS ASSY ...
Page 97: ...DCA400SSI GENERATOR OPERATION AND PARTS MANUAL REV 2 11 03 08 PAGE 97 NOTES ...