background image

page 50 —gb2000 balloon lighT• operaTion and parTs manual — rev. #3 (08/30/12) 

terMs and COnditiOns Of sale — parts

paymenT Terms

Terms of payment for parts are net 30 days.

FreighT poliCy

All  parts  orders  will  be  shipped  collect  or 

prepaid with the charges added to the invoice. 

All  shipments  are  F.O.B.  point  of  origin. 

Multiquip’s  responsibility  ceases  when  a 

signed manifest has been obtained from the 

carrier, and any claim for shortage or damage 

must be settled between the consignee and 

the carrier.

minimum order

The minimum charge for orders from Multiquip 

is  $15.00  net.  Customers  will  be  asked  for 

instructions regarding handling of orders not 

meeting this requirement.

reTurned goods poliCy

Return  shipments  will  be  accepted  and 

credit will be allowed, subject to the following 

provisions:

1.  A  Returned  Material  Authorization 

must be approved by Multiquip prior to 

shipment. 

2.  To obtain a Return Material Authorization, 

a  list  must  be  provided  to  Multiquip 

Parts Sales that defi nes item numbers, 

quantities, and descriptions of the items 

to be returned.
a.  The parts numbers and descriptions 

must match the current parts price 

list.

b.  The list must be typed or computer 

generated.

c.  The  list  must  state  the  reason(s) 

for the return.

d.  The  list  must  reference  the  sales 

order(s)  or  invoice (s)  under 

which  the  items  were  originally 

purchased.

e.  The  list  must  include  the  name 

and  phone  number  of  the  person 

requesting the RMA.

3.  A copy of the Return Material Authorization 

must accompany the return shipment.

4.  Freight is at the sender’s expense. All 

parts must be returned freight prepaid to 

Multiquip’s designated receiving point.

5.  Parts  must  be  in  new  and  resalable 

condition,  in  the  original  Multiquip 

package (if any), and with Multiquip part 

numbers clearly marked.

6.  The following items are not returnable:

a.  Obsolete parts. (If an item is in the 

price  book  and  shows  as  being 

replaced  by  another  item,  it  is 

obsolete.)

b.  Any  parts  with  a  limited  shelf  life 

(such as gaskets, seals, “O” rings, 

and other rubber parts) that were 

purchased  more  than  six  months 

prior to the return date.

c.  Any  line  item  with  an  extended 

dealer  net  price  of  less  than 

$5.00.

d.  Special order items.
e.  Electrical components.
f.  Paint, chemicals, and lubricants.
g.  Decals and paper products.
h.  Items purchased in kits.

7.  The sender will be notifi ed of any material 

received that is not acceptable.

8.  Such  material  will  be  held  for  five 

working days from notifi cation, pending 

instructions.  If  a  reply  is  not  received 

within  five  days,  the  material  will  be 

returned to the sender at his expense.

9.  Credit on returned parts will be issued 

at dealer net price at time of the original 

purchase,  less  a  15%  restocking 

charge.

10.  In cases where an item is accepted, for 

which the original purchase document 

can not be determined, the price will be 

based on the list price that was effective 

twelve months prior to the RMA date.

11.  Credit  issued  will  be  applied  to  future 

purchases only.

priCing and rebaTes

Prices  are  subject  to  change  without  prior 

notice.  Price  changes  are  effective  on  a 

specifi c  date  and  all  orders  received  on  or 

after that date will be billed at the revised price. 

Rebates for price declines and added charges 

for price increases will not be made for stock 

on hand at the time of any price change.

Multiquip  reserves  the  right  to  quote  and 

sell  direct  to  Government  agencies,  and  to 

Original  Equipment  Manufacturer  accounts 

who use our products as integral parts of their 

own products.

speCial expediTing serviCe

A  $35.00  surcharge  will  be  added  to  the 

invoice  for  special  handling  including  bus 

shipments,  insured  parcel  post  or  in  cases 

where Multiquip must personally deliver the 

parts to the carrier.

limiTaTions oF seller’s liabiliTy

Multiquip  shall  not  be  liable  hereunder  for 

damages in excess of the purchase price of 

the item with respect to which damages are 

claimed, and in no event shall Multiquip be 

liable for loss of profi t or good will or for any 

other  special,  consequential  or  incidental 

damages.

limiTaTion oF WarranTies

No  warranties,  express  or  implied,  are 

made in connection with the sale of parts or 

trade accessories nor as to any engine not 

manufactured by Multiquip. Such warranties 

made  in  connection  with  the  sale  of  new, 

complete  units  are  made  exclusively  by  a 

statement  of  warranty  packaged  with  such 

units,  and  Multiquip  neither  assumes  nor 

authorizes  any  person  to  assume  for  it 

any  other  obligation  or  liability  whatever  in 

connection with the sale of its products. Apart 

from  such  written  statement  of  warranty, 

there are no warranties, express, implied or 

statutory, which extend beyond the description 

of the products on the face hereof.

Effective:  February 22, 2006

Summary of Contents for Globug GB2000

Page 1: ...nual THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES To find the latest revision of this publication visit our website at www multiquip com Globug MODEL GB2000 Light Tower Mount type balloon lig...

Page 2: ...page 2 gb2000 balloon light operation and parts manual rev 3 08 30 12 proposition 65 warning Diesel engine exhaust and some of...

Page 3: ...900119 and Above 19 Type 1 Setup S N G1900118 and Below 20 22 Type 2 Setup S N G1900119 and Above 23 27 Lamp Lighting Options 28 33 Operation 34 35 Maintenance 36 38 Wiring Diagram 39 Explanation Of C...

Page 4: ...View Parts Diagrams Order Parts Print Specification Information Note Discounts Are Subject To Change Goto www multiquip com and click on Order Parts to log in and save Use the internet and qualify fo...

Page 5: ...sages specifically address the level of exposure to the operator and are preceded by one of four words danger Warning CauTion or noTiCe saFeTy symbols danger Indicates a hazardous situation which if n...

Page 6: ...pplications NOTICE This equipment should only be operated by trained and qualified personnel 18 years of age and older Whenever necessary replace nameplate operation and safety decals when they become...

Page 7: ...ract mast while unit is operating never use the light tower mast as a crane do noT lift anything with the mast alWays lower the light tower when not in use or if high winds or electrical storms are ex...

Page 8: ...e governor Damage to the engine or equipment can result if operating in speed ranges above the maximum allowable never tip the engine to extreme angles during lifting as it may cause oil to gravitate...

Page 9: ...re mechanically sound and in good operating condition alWays shutdown engine before transporting Make sure the hitch and coupling of the towing vehicle are rated equal to or greater than the trailer g...

Page 10: ...jack to adjust the trailer height to a level position while parked never allow any person or animal to stand underneath the equipment while lifting do noT lift equipment to unnecessary heights loadin...

Page 11: ...h Backfeed to a utility system can cause electrocution and or property damage never connect the generator to a building s electrical system without a transfer switch or other approved device All insta...

Page 12: ...in a well ventilated environmenttoavoidtheriskofadangerousconcentration of combustible gasses If the battery liquid dilute sulfuric acid comes into contact with clothing or skin rinse skin or clothin...

Page 13: ...odel GB2000 Lamp Type 1000 W Metal Halide X2 Number of Bulbs 2 Current 8 2 A Voltage 238 268 V Lumens 220 000 lm Fan Current 0 87 A Voltage 115 V Dimensions Storage 12 2 x 12 2 x 39 in 310 x 310 x 990...

Page 14: ...dimensions Table 2 Dimensions Reference Letter Dimension in mm Reference Letter Dimension in mm A 13 25 337 E 3 12 79 3 B 40 0 1 016 F 9 75 248 C 35 5 902 G 8 25 210 D 34 5 876 H 4 62 117 Figure 1 Dim...

Page 15: ...ht operation and parts manual rev 3 08 30 12 page 15 footcandle plot 1 grid 40 ft Illuminance Footcandle Diameter Feet 30 9 20 30 10 52 5 65 2 91 1 117 0 5 156 0 25 232 30 20 10 5 2 1 0 5 0 25 Figure...

Page 16: ...ity support and special events The balloon light assembly is supported by two 1000 watt metal halide lamps self inflating durable polyester balloon bag protective lamp guard quick disconnect communal...

Page 17: ...gb2000 balloon light operation and parts manual rev 3 08 30 12 page 17 notes...

Page 18: ...ocking Pin Locks the lamp fixture in place when attached to the pole on the bracket 3 Bracket Plate Attaches to the Tbar and mast interface of the light tower to allow the GB2000 to be installed 4 Jun...

Page 19: ...inflation circuit 4 Adapter Plate Attaches to the T Bar and mast interface of the light tower to allow the GB2000 to be installed 5 Junction Box Holds the electrical connection and cables to connect t...

Page 20: ...meters Contact with overhead power lines or other obstructionscouldresultinequipment damage serious injury or death STOWED POSITION MAST LOCK DISCONNECT NEGATIVE BATTERY CABLE 2 For MLT series light...

Page 21: ...provided LAMP BOLT NUT WASHERS WASHERS CAUTION Make sure that theT bar is supported before removing the two screws and nuts to prevent T Bar from falling off the mast extension REMOVE HHC SCREW 2 1 2...

Page 22: ...power receptacle on the generator 2 Connect the other end of the fan power cable quick disconnect end to the 3 pin AC power cable on the junction box 10 PIN Lamp Power cable CONNECTION 1 Unscrew the p...

Page 23: ...ss of 30 ft 9 meters Contact with overhead power lines or other obstructionscouldresultinequipment damage serious injury or death STOWED POSITION MAST LOCK NOTICE The new lamp adapter plate requires n...

Page 24: ...f each bracket facing inward toward the mast The raised end of each bracket should be facing outward type 2 setup S N G1900119 and above 5 Next insert a bolt 4 and flat washer 4 thru the mounting hole...

Page 25: ...HER 8 LOCK WASHER 4 HEX NUT 4 SUPPORT BRACKET 2 T BAR LAMP ADAPTER PLATE BUBBLE LEVEL SPACER LOW END BOLT 1 NOTES It is important for the adapter SPACER to seat against the T Bar as shown above 2 For...

Page 26: ...e fan power cable connection 1 Insert the 38 ft 11 5 meters 3 prong AC power plug on the fan power cable as shown in Figure 20 into the GFCI power receptacle on the generator 2 Connect the other end o...

Page 27: ...Figure 21 as a reference when determining orientation of lamps and receptacles on T Bar Figure 21 is looking at the light tower from the rear to the front Figure 21 Light Tower Orientation View J1 J3...

Page 28: ...the GB2000 lamp assembly is employed only two of the existing rectangular lamps bottom lamps recommended will be available for use Please reference Figure 22 thru Figure 27 for the various lighting o...

Page 29: ...tions Table 3 Figure 23 Option 2 Lighting Configuration LAMP 4 TOP LAMP 2 TOP 1 2 3 4 GB2000 NOT USED NOT USED LAMP 3 BOTTOM LAMP 1 BOTTOM 4 Lamps Installed on T Bar Only GB2000 Operational CB1 CB2 CB...

Page 30: ...2 lamp lighting options Figure 24 Option 3 Lighting Configuration CB1 CB2 CB3 CB4 ON ON ON ON ON ON CB1 CB2 LT12 LAMP CIRCUIT BREAKERS MLT LAMP CIRCUIT BREAKERS 2 Top Lamps Removed GB2000 Operational...

Page 31: ...Figure 25 Option 4 Lighting Configuration LAMP 4 TOP LAMP 2 TOP 4 Lamps Installed on T Bar GB2000 Operational 2 Bottom Lamps Operational GB2000 NOT USED NOT USED LAMP 3 BOTTOM LAMP 1 BOTTOM CB1 CB2 CB...

Page 32: ...s Figure 26 Option 5 Lighting Configuration LAMP 4 TOP LAMP 2 TOP 1 2 3 4 GB2000 NOT USED NOT USED CB1 CB2 CB3 CB4 ON ON ON ON ON ON CB1 CB2 LT12 LAMP CIRCUIT BREAKERS MLT LAMP CIRCUIT BREAKERS LAMP 3...

Page 33: ...e 33 lamp lighting options Figure 27 Option 6 Lighting Configuration LAMP 4 TOP LAMP 2 TOP 1 2 3 4 GB2000 CB1 CB2 CB3 CB4 ON ON ON ON ON ON CB1 CB2 LT12 LAMP CIRCUIT BREAKERS MLT LAMP CIRCUIT BREAKERS...

Page 34: ...lloon should begin to inflate CAUTION DO NOT use excessive force when zipping or unzipping the balloon The possibility exists of the zipper tearing which would make the balloon unusable BALLOON FULLY...

Page 35: ...OR STARTER SWITCH RUN HEAT START STOP HOUR METER AC VOLTMETER AC CIRCUIT BREAKER 120 240V 25A 25A 120V 20A 25A TO BALLAST COMPARTMENT 4 PIN POWER CABLE MAIN CIRCUIT BREAKER ON GFCI CIRCUIT BREAKER ON...

Page 36: ...re burns if hot lamp is touched CAUTION Always shutdown power source and remove balloon assembly from mast when replacing a broken lamp Utmost care should be taken in handling broken lamp The possibil...

Page 37: ...de out the old or worn balloon over the top of the lamp guard assembly See Figure 39 Figure 39 Removing Old Balloon NOTICE Do not use excessive force when screwing the lamp to prevent lamp from breaki...

Page 38: ...h Is lamp loose Screw lamp securely into socket Is power connector disconnected or loose Connect disconnected connector Is model of lamp incompatible Use genuine MQ lamp Lamp only lights for a short t...

Page 39: ...BLE LAMP 2 CP AC PLUG CP CABLE BALLOON 3 CP CABLE FAN CP SOCKET SOCKET RED RED RED M F M M M M M M F F F F M F M F M F M F M F M F M F F M F M F F WHITE WHITE WHITE BLACK BLACK BLACK BLACK BLACK BLACK...

Page 40: ...ot guarantee the availability of the parts listed NOTICE When ordering a part that has more than one item number listed check the remarks column for help in determining the proper part to order QTy Co...

Page 41: ...uggested Spare Parts gb2000 bALLOON LIGHT 1 to 3 units Qty P N Description 2 E000080700 LAMP 2 A100085100 BALLOON CLOTH CP 3 A400038300 FILTER NOTICE Part numbers on this Suggested Spare Parts list ma...

Page 42: ...cal assy 3 2 14 18 20 47 48 60 43 31 39 59 60 60 60 60 59 60 20 14 14 10 8 7 6 13 13 25 26 19 24 21 21 22 35 34 53 28 29 26 49 46 14 51 37 32 12 12 62 42 41 26 26 38 56 15 11 27 11 9 30 58 1 44 61 61...

Page 43: ...0119 ABOVE 19 A400240602 POLE JOINT 1 1 20 A400240701 POLE JOINT 2 4 21 A400243501 POLE JOINT 3 3 22 A200075900 VESSEL 1 23 A400240801 STOPPER 4 24 E000098700 CABLE CLAMP 1 25 A300215000 CABLE BALLOON...

Page 44: ...ssy CONTINUED 3 2 14 18 20 47 48 60 43 31 39 59 60 60 60 60 59 60 20 14 14 10 8 7 6 13 13 25 26 19 24 21 21 22 35 34 53 28 29 26 49 46 14 51 37 32 12 12 62 42 41 26 26 38 56 15 11 27 11 9 30 58 1 44 6...

Page 45: ...4 50 2204220130 PLATE CAP 1 51 E000103600 NUT SMM25 1 52 1800001000 SHEET TOP 1 53 A200075601 PLATE FAN 1 54 A400244701 CABLE THERMO 3 CP M 1 INCLUDES TERMINAL 55 A400244801 CABLE THERMO 4 CP F 1 INC...

Page 46: ...page 46 gb2000 balloon light operation and parts manual rev 3 08 30 12 BRACKET AND J BOX assy S N G1900118 and BELOW 8 13 18 10 6 12 3 16 4 15 7 9 5 14 11 1 11 11 7 17 2 TYPE 1 ADAPTER...

Page 47: ...x12 1 6 0033103000 NUT M3 1 7 A300215300 CABLE LAMP 3 CP 2 INCLUDES TERMINAL 8 A200076300 ADAPTER CP 1 9 A300215500 AC PLUG CP 1 INCLUDES TERMINAL 10 0033104000 NUT M4 3 11 0024304008 SCREW TRUSS M4x8...

Page 48: ...balloon light operation and parts manual rev 3 08 30 12 BRACKET AND J BOX assy S N G1900119 and ABOVE 13 17 14 22 8 19 20 10 18 21 17 9 15 5 4 16 7 15 5 4 3 7 12 1 6 2 11 11 SPARE PART 22 23 TYPE 2 UN...

Page 49: ...00 CABLE LAMP 3 CP W TERMINALS 2 8 A100088602 ADAPTER BRACKET 1 9 A300255600 AC PLUG CP W TERMINALS 1 10 A400288000 RETAINER 2 11 0024304008 SCREW TRUSS M4 X 8 6 12 E000072600 CABLE CLAMP 2 13 0013112...

Page 50: ...products h Items purchased in kits 7 The sender will be notified of any material received that is not acceptable 8 Such material will be held for five working days from notification pending instructio...

Page 51: ...gb2000 balloon light operation and parts manual rev 3 08 30 12 page 51 notes...

Page 52: ...161 339 2223 Fax 0161 339 3226 Canada Multiquip 4110 Industriel Boul Laval Quebec Canada H7L 6V3 Contact jmartin multiquip com Tel 450 625 2244 Tel 877 963 4411 Fax 450 625 8664 COPYRIGHT 2012 MULTIQU...

Reviews: