page 18 — gac2.2H 60 Hz geNeRaTOR• OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10)
cOMpOnents (generatOr)
8.
muffler/Heat shield – Used to reduce noise and
emissions.
NeveR touch this heat shield when the
generator/welder is in use. Always allow time for engine
to cool before servicing.
9.
air cleaner – Prevents dirt and other debris from
entering the fuel system. Remove wing-nut on top of air
filter cannister to gain access to filter element.
NeveR
run the engine without an air cleaner.
10.
spark plug – Provides spark to the ignition system.
Set spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch)
Clean spark plug once a week.
11.
Fuel Tank cap – Remove cap to add unleaded
gasoline to the fuel tank. Replenish with clean unleaded
gasoline. Make sure cap is tightened securely.
dO
NOT over fill.
12.
Fuel cock lever – Turn lever downward to start (down)
the flow of fuel into the carburetor. Turn upward to stop
(up) the flow of fuel.
13.
choke lever – Used for starting the engine. Close
the choke lever when starting a cold engine or in
cold weather conditions. The choke enriches the fuel
mixture. Open the choke lever if starting a warm engine
or in warm weather conditions.
Figure 4. Generator Components (Continued)
14.
Throttle lever – Regulates engine speed.
15.
engine – This generator uses a 5.0 HP Honda air-
cooled, 4-stroke, single cylinder, overhead camshaft
gasoline engine. Engine uses unleaded gasoline.
16.
engine Oil drain plug – Remove this plug to drain
engine oil from the crankcase.
17.
Recoil starter (pull rope) – Manual-starting method.
Pull the starter grip until resistance is felt, then pull
briskly and smoothly.
18.
Fuel Tank – Fuel tank capacity is 3.16 gallons (12 liters)
19.
Fuel gauge – This gauge is located on top of the fuel
tank. Read this gauge to determine when fuel is low.
NOTICE
This
HONda engine is equipped with a low oil shutdown
capability. A built in sensor will automatically turn off the
engine should the oil level fall below a safe operating
condition. Make sure the generators is placed on level
ground. Placing the generators on level ground will
ensure that the low oil sensor will function properly.
Summary of Contents for GAC2.2H
Page 9: ...gac2 2H 60 hz GENERATOR operation and parts manual rev 1 03 31 10 page 9 NOTES...
Page 13: ...gac2 2H 60 hz GENERATOR operation and parts manual rev 1 03 31 10 page 13 note...
Page 34: ...page 34 gac2 2H 60 hz gENERATOR operation and parts manual rev 1 03 31 10 generator assy...
Page 36: ...page 36 gac2 2H 60 hz gENERATOR operation and parts manual rev 1 03 31 10 CONTROL BOX assy...
Page 38: ...page 38 gac2 2H 60 hz gENERATOR operation and parts manual rev 1 03 31 10 PIPE FRAME assy...
Page 73: ...gac2 2H 60 hz GENERATOR operation and parts manual rev 1 03 31 10 page 73 notes...