background image

MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0  (10/28/04) — PAGE 17

MQ GA-2.9R — CONTROLS AND INDICATORS

This  

ROBIN

 engine is equipped

with a low oil shutdown capability. A
built in sensor will automatically turn

off the engine should the oil level
fall below a safe operating condition.

Make sure the generator is placed on level ground. Placing the
generator on level ground will ensure that  the low oil sensor will
function properly.

NOTE

6

.

Operation/ON-OFF Switches –

 Place engine 

ON/OFF

switch in the 

"ON" 

position for normal operation. 

To turn-

off the generator place switch in the "

OFF

" position.

7

.

Generator Housing  –

  Contains the rotor, rectifer field

coil assembly, aramature, bearings and other components
that make up generator asembly.

8

.

Spark Plug –

  Provides spark to the ignition system. Set

spark plug gap to 0.6 - 0.7 mm (0.024 - 0.028 inch). Clean
spark plug once a week.

9

.

Muffler/Heat Shield –

  Used to reduce noise and emissions.

NEVER

 touch this 

heat shield

 when the generator is in

use. Always allow time for the generator to cool down before
performing maintenance.

10

. Oil  Dipstick/ Filler Cap–

 Remove the filler cap dipstick

when checking the engine oil level. Add engine oil through
this filler port. See Table 4 for recommended type engine
oil.

11

. Oil Drain Plug –

 Remove this plug to drain engine oil from

the crankcase.

12

. Carburetor Fuel Cup –

  Inspect the fuel cup weekly for

water and dirt. Clean as referenced in the maintenance
section of this manual.

13

. Choke Lever –

  Used  for starting the engine. 

Close 

the

choke lever when starting a cold engine or in cold weather
conditions. The choke enriches the fuel mixture. 

Open 

the

choke lever if starting a warm engine or in warm weather
conditions.

14

. Fuel Cock Lever –

  Turn this lever 

downward

 to 

start

(down)the flow of fuel to the carburetor. Turn 

upward 

to

stop (

up

)

  the flow of fuel.

15

. Throttle Lever –

  Used to adjust engine RPM speed. This

unit is set at the factory and is not adjustable.

16

. Recoil Starter (Pull Rope) –

  Used for manual-starting of

the engine. Pull the starter grip until resistance is felt, then
pull briskly and smoothly.

17

. Engine –

  This generator uses  a  5.1 HP 

 ROBIN 

air-

cooled, 4-stroke , single cylinder, overhead camshaft
gasoline engine. Engine uses unleaded fuel.

18

. Air Cleaner –

  Prevents dirt and other debris from entering

the fuel system. Remove wing-nut on top of air filter
cannister to gain access to filter element. 

NEVER

 run the

engine without an air cleaner.

19

. Fuel Gauge –

  Read this gauge to determine when fuel is

low

.

20

. Fuel Gauge/Tank –

  Remove this cap to add unleaded

gasoline to the fuel tank. 

Replenish

 with

 clean unleaded

gasoline. Make sure cap is tightened securely. 

DO NOT

over fill. Fuel tank capacity is  3.17 gallons (12 liters).

21

. Lifting Bail Eye –

  Attach a rope or chain to this lifting eye

when lifting of the generator is required. Never stand
underneath the generator while it is being lifted. Place lifting
eye in down position when not in use.

1

.

120V Output Receptacle –

 This 

NEMA L5-20R twist-

lock receptacle will provide 120V, 20 amps, 60 Hz.

2

.

GFCI Receptacle –

  This receptacle will provide 120V at

all times.

3

.

AC-Voltmeter –

  This voltmeter indicates (with a mark) the

rated 60 Hz, single phase output voltage. In addition the
voltmeter can also be used as a diagnostic tool. If the
voltmeter indicator (needle) is below the rated voltage,
engine problems may exist (low/high RPM's). To prevent
damage to the generator or power tools turn the generator

OFF

 and consult your authorized 

MQ

 service dealer.

4

.

Main Circuit Breaker –

  This single-pole 22 amp breaker

protects the generator from short circuiting or overloading.
When starting the generator 

always

 have the circuit breaker

placed in the "

OFF

" position.

5

.

Ground –

  This ground connection point should be

connect to a good earth ground (ground rod).

 ALWAYS

 allow time for the generator to 

cool

down

 before performing maintenance.

WARNING

WARNING

WARNING

WARNING

WARNING

Summary of Contents for GA-2.9R

Page 1: ...OPERATION AND PARTS MANUAL MODEL GA 2 9R PORTABLE AC GENERATOR GASOLINE ENGINE Revision 0 10 28 04 THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALLTIMES ...

Page 2: ...PAGE 2 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 ...

Page 3: ...trademarks of Multiquip Inc and may not be used reproduced or altered without written permission All other trademarks are the property of thier respective owners and used with permission ThismanualMUSTaccompanytheequipmentatalltimes Thismanualisconsideredapermanentpartoftheequipmentandshould remain with the unit if resold The information and specifications included in this publication were in effe...

Page 4: ...ation and Parts Manual Generator Component Drawings Nameplate and Decals 34 35 Generator Assembly 36 37 Control Box Assembly 38 39 Pipe Frame Assembly 40 41 MQ GA 2 9R AC Portable Generator Here s How To Get Help 3 Table Of Contents 4 Parts Ordering Procedures 5 Dimensions 6 Specifications 7 Safety Alert Message Symbols 8 9 Rules for Safe Operation 10 12 Operation and Safety Decals 13 General Info...

Page 5: ...7 1244 FAX 800 672 7877 310 537 3700 FAX 310 637 3284 MAYCO PARTS 800 306 2926 FAX 800 672 7877 310 537 3700 FAX 310 637 3284 SERVICE DEPARTMENT 800 421 1244 FAX 310 537 4259 310 537 3700 TECHNICAL ASSISTANCE 800 478 1244 FAX 310 631 5032 WARRANTY DEPARTMENT 800 421 1244 EXT 279 FAX 310 537 1173 310 537 3700 EXT 279 Note Unlessotherwiseindicatedbycustomer all orders are treated as Standard Orders ...

Page 6: ...PAGE 6 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 MQ GA 2 9R DIMENSIONS Figure 1 Dimensions ...

Page 7: ... i x a M 9 2 C A V s e g a t l o V 0 2 1 C A V 0 2 1 s p m A s u o u n i t n o C x a M 7 1 2 2 4 2 M P R d e e p S d e t a R 0 0 6 3 r o t c a F r e w o P 0 1 m m n i H x W x L n o i s n e m i D 8 1 X 6 1 X 0 2 5 6 4 X 0 1 4 X 0 1 5 g k s b l t h g i e W t e N y r D e n i g n E s e d u l c n I 9 4 8 0 1 E N I G N E l e d o M 0 1 2 0 2 D 0 7 1 X E N I B O R e p y T d a e h r e v O r e d n i l y C e...

Page 8: ...a MQ GA 2 9R Portable Generator will be referenced with Hazard Symbols which appear throughout this manual and will be referenced in conjunction with Safety Message Alert Symbols Engine exhaust gases contain poisonous carbon monoxide This gas is colorless and odorless and can cause death if inhaled NEVER operate this equipment in a confined area or enclosed structure that does not provide ample fr...

Page 9: ...N CAUTION CAUTION CAUTION Eye and Hearing Hazards CAUTION CAUTION CAUTION CAUTION CAUTION Other important messages are provided throughout this manual to help prevent damage to your portable generator other property or the surrounding environment Equipment Damage Hazards CAUTION CAUTION CAUTION CAUTION CAUTION ALWAYS place the power source circuit breakers or ON OFF switch in the OFF position when...

Page 10: ...e hot exhaust manifold muffler or cylinder Allow these parts to cool before servicing engine or generator ALWAYS wear proper respiratory mask hearing and eye protection equipment when operating the generator Whenever necessary replace nameplate operation and safety decals when they become difficult read Manufacturer does not assume responsibility for any accident due to equipment modifications NEV...

Page 11: ...sure that electrical circuits are properly grounded per the National Electrical Code NEC and local codes before operating generator Severe injury or death by electrocution can result from operating an ungrounded generator ALWAYS make sure generator is properly grounded to a suitable earth ground GROUND ROD See installation in this manual NEVER use gas piping as an electrical ground Maintenance Saf...

Page 12: ...an emergency DANGER DANGER DANGER DANGER DANGER ELECTROCUTION HAZARDS ELECTROCUTION HAZARDS ELECTROCUTION HAZARDS ELECTROCUTION HAZARDS ELECTROCUTION HAZARDS During operation of this generation there exists the possibility of electrocution electrical shock or burn which can cause severe bodily harm or even DEATH To avoid these hazards NEVER use damaged or worn cables when connecting equipment to t...

Page 13: ...R portable generator is equipped with a number of safety decals Figure 2 These decals are provided for operator safety and maintenance information The illustration below shows these decals as they appear on the machine Should any of these decals become unreadable replacements can be obtained from your dealer Figure 2 Operation and Safety Decals ...

Page 14: ... breaker is provided on the control panel Make sure to switch this circuit breaker to the OFF position prior to starting the engine Excitation System The MQ GA 2 9R generator uses a magnet attached to a flywheel to produce AC voltage from a lamp coil beneath the flywheel As the magnet passes the coil it produces approximately 19 22 AC volts This voltage 19 22 VAC is then sent to the control box th...

Page 15: ...W generator 2 SMALL MOTORS Drills and other small power tools Total the running wattage and multiply by 2 Example A 1 inch drill runs at 1 KW use a 2 KW generator 3 LARGE MOTORS Submersible pumps table saws etc Total the running wattage and multiply by 3 Example A conveyor belt runs at 8 KW use a 24 KW generator Extension Cables When electric power is to be provided to various tools or loads at so...

Page 16: ...PAGE 16 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 MQ GA 2 9R CONTROLS AND INDICATORS Figure 2 Generator Controls and Components ...

Page 17: ...r Used to adjust engine RPM speed This unit is set at the factory and is not adjustable 16 Recoil Starter Pull Rope Used for manual starting of the engine Pull the starter grip until resistance is felt then pull briskly and smoothly 17 Engine This generator uses a 5 1 HP ROBIN air cooled 4 stroke single cylinder overhead camshaft gasoline engine Engine uses unleaded fuel 18 AirCleaner Prevents dir...

Page 18: ...toppedandhashadanopportunity tocooldown Intheeventofafuelspill DONOTattempttostart theengineuntilthefuelresiduehasbeencompletelywipedup andtheareasurroundingtheengineisdry Ifgeneratorisplaced inatruckbedwithaplasticliner REMOVEgeneratorfromtruck bed and place on ground Figure 4 to refuel This possibility existoffireorexplosionduetostaticelectricity DANGER DANGER DANGER DANGER DANGER ...

Page 19: ...m but harmless if allowed to mix with the outside air If the generator is installed indoors you must make provisions for venting the engine exhaust to the outside of the building Generator Grounding To guard against electrical shock and possible damage to the equipment it is important to provide a good EARTH ground Always use the ground terminal on the generator to ground the generator Article250 ...

Page 20: ...sed to connect the generator to a suitable ground The ground cable should be 8 size wire minimum At the generator connect the terminal of the ground cable between the lock washer and the nut Figure 5 and tighten the nut fully Connect the other end of the ground cable to a suitable earth ground ground rod MQ GA 2 9R INSTALLATION Figure 5 Generator Grounding ...

Page 21: ... Power Tools When using power tools or electrical equipment requireing AC power from the generator make sure connecting power tool cable Figure 6 has a ground as shown in Figure Extension Cable Whenelectricpoweristobeprovidedtovarioustoolsorloadsat some distance from the generator extension cords are normally used Cables should be sized to allow for distance in length and amperage so that the volt...

Page 22: ...re9 to determin if the fuel level is low If fuel is low replenish with clean unleaded fuel Engine Oil Check 1 Tochecktheengineoillevel placethegeneratoronsecure level ground with the engine stopped 2 Remove the filler dipstick from the engine oil filler hole Figure 7 and wipe clean ALWAYS wear approved eye and hearing protection before operating the generator e p y T l i O 4 e l b a T n o s a e S ...

Page 23: ...n Figure 10 Main Breaker OFF Position CAUTION CAUTION CAUTION CAUTION CAUTION DO NOT attempt to operate this generator until the Safety General Information and Inspection sections of this manual have been read and thoroughly understood Figure 13 Engine ON OFF Switch ON 5 Grasp the starter grip Figure 14 and slowly pull it out The resistancebecomesthehardestatacertainposition corre spondingtothecom...

Page 24: ...ex receptacle and the 120V twist lock receptacle MQ GA 2 9R INITIAL START UP ENGINE OPERATION Connecting the Load 1 Connect the load to the output receptacles 2 Place the main circuit breaker Figure 17 in the ON position Figure 16 120VAC GFCI Receptacle Stopping The Engine Normal Shutdown 1 Place the main circuit breaker Figure 10 in the OFF position 2 Remove the load from the generator and let th...

Page 25: ...il the gasoline in the carburetor is completely consumed Completely drain the oil from the crankcase and refill with fresh oil Remove the spark plug pour 2 or 3 cc of SAE 30 oil into the cylinder and crank slowly to distribute the oil SlowlyrotatetheengineafewtimeswiththestarterRopeand install a new plug Pull out the starter rope slowly and stop at the compression point Clean all external parts of...

Page 26: ... e e p S e l d I T S U J D A K C E H C 2 X e c n a r a e l C e v l a V T S U J D A K C E H C 2 X s e n i l l e u F K C E H C 2 y r a s s e c e n f i e c a l p e r s r a e y 2 y r e v E n i d e s u n e h w y l t n e u q e r f e r o m e c i v r e S 1 Y T S U D s a e r a y l l a c i n a h c e m e r a d n a s l o o t r e p o r p e h t e v a h u o y s s e l n u r e l a e d e c i v r e s r u o y y b d e...

Page 27: ...ne oil with recommended type oil as listed in Table 4 For engine oil capacity see Table 1 engine specifications DO NOT overfill 4 Install drain bolt with sealing washer and tighten se curely Figure 21 Engine Oil Draining Figure 20 Spark Plug Gap ENGINEAIRCLEANER 1 Remove the air cleaner cover and foam filter element as shown in Figure 22 2 Tap the paper filter element Figure 22 several times on a ...

Page 28: ...PAGE 28 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 MQ GA 2 9R WIRING DIAGRAM Figure 23 Generator EngineWiring Diagram ...

Page 29: ... k o r b t i n u n o i t i n g i r o t s i n a r T d e l u o f f i g u l p k r a p s e c a l p e R n e k o r b h c t i w s p o t S t r a t S l i o o N d e r i u q e r s a l i o d d A s k n i l b p m a l m r a l a e r u s s e r p l i O g n i t r a t s n o p u r o s n e s l i o t i u c r i c n w o d t u h s c i t a m o t u A k c e h C o n t u p t u o r e w o p t n e i c i f f u s n I n o i s s e r p...

Page 30: ... a p s g n o r W g u l p k r a p s e p y t d e t s e g g u s s e r u t c a f u n a m h t i w g u l p k r a p s e c a l p e R y l s u o i n i t n o c s i r o l o c t s u a h x E E T I H W g n o r w s i l i o g n i t a c i r b u L y t i s o c s i v y t i s o c s i v t c e r r o c h t i w l i o g n i t a c i r b u l e c a l p e R s g n i r n r o W s g n i r e c a l p e R y l s u o i n i t n o c s i r...

Page 31: ... o t t u p t u o e g a t l o V M P R 0 5 6 3 l a m r o n d e e p s e l d i M P R 0 0 5 2 d e d a o l n u g n i r i w l a n r e t n i x o b l o r t n o C n o i t c n u f l a m g n i r i w x o b l o r t n o c k c e h C n o n r u t t o n l l i w r e k a e r b t i u c r i C D A O L O N r e k a e r b t i u c r i c e v i t c e f e D r e k a e r b t i u c r i c e c a l p e R n o n r u t l l i w r e k a e...

Page 32: ...ere indicated this shows that the corresponding part is utilized only with this specific model number or model number variant Items Found In the Items Number Column All parts with same symbol in the number column or belong to the same assembly or kit MQ GA 2 9R EXPLANATION OF CODE IN REMARKS COLUMN If more than one of the same reference number is listed the last one listed indicates newest or late...

Page 33: ...pare Parts List may supercede replace the P N shown in the text pages of this book NOTE MQ GA 2 9R GENERATOR 1 TO 3 UNITS WITH ROBIN EX170D20210 ENGINE 1 to 3 Units Qty P N Description 1 A9924800014 CAP FUEL TANK 1 A9924800004 FUEL FILTER FUEL TANK 3 0650140150 SPARK PLUG 3 2772361407 ELEMENT AIR CLEANER 1 5825011118 ROPE RECOIL STARTER ...

Page 34: ...PAGE 34 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 MQ GA 2 9R NAME PLATE AND DECALS NAMEPLATE AND DECALS ...

Page 35: ...AMEPLATE 1 CONTACT MQ PARTS DEPT 4 0800628504 DECAL GROUND 1 S 1123 5 8700611804 DECAL WARNING DANGEROUS GAS 1 S 4984 6 8700611904 DECAL DANGER ELECTRICAL SHOCK HAZ 1 S 4985 7 A92120000 DECAL OPERATING INSTRUCTIONS 1 8 7900636004 DECAL CAUTION OPER AT 3600 RPM ONLY 1 S 4461 9 0820610404 DECAL WARNING 1 S 3627 10 35137 DECAL CAUTION 1 11 A2561000103 DECAL MQ MULTIQUIP 2900 1 MQ GA 2 9R NAME PLATE A...

Page 36: ...PAGE 36 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 MQ GA 2 9R GENERATOR ASSY GENERATOR ASSY ...

Page 37: ...ET BOLT ROTOR 1 3 0801086004 SET WASHER BEARING 1 4 0040008000 SPRINGWASHER 1 5 7921341803 ARMATURE ASSY 1 S N 5497956 AND BELOW 5 A2135000203 ARMATURE ASSY 1 S N 5497957 AND ABOVE 6 7931315002 END BRACKET C SIDE 1 7 7931315102 END BRACKET B SIDE 1 8 7875021523 GUIDE PANEL AIR 1 9 7681331003 COVER 1 10 7681344204 SET BOLT STATOR 4 11 0040006000 SPRINGWASHER 4 12 0041206000 PLAINWASHER 4 13 7871329...

Page 38: ...PAGE 38 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 MQ GA 2 9R CONTROL BOX ASSY CONTROL BOX ASSY ...

Page 39: ...NTROL PANEL 1 6 0601804889 CIRCUIT BREAKER 1 KM 51 22A 7 3011816004 BRACKET CIRCUIT BREAKER 1 8 0021004010 MACHINE SCREW 2 9 0601806819 AC VOLTMETER 1 DE450 011 0 120V 10 0601812598 RECEPTACLE 1 5 20R 125V 20A 11 0601812592 RECEPTACLE 1 L5 20R 125V 20A 12 0021004010 MACHINE SCREW 4 12A 0207004000 HEX NUT 4 13 0021004015 MACHINE SCREW 4 13A 0207004000 HEX NUT 1 14 0017106016 HEX HEAD BOLT 4 15 0017...

Page 40: ...PAGE 40 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 MQ GA 2 9R PIPE FRAME ASSY PIPE FRAME ASSY ...

Page 41: ...65000102 FUELTANK 1 7 A9924800014 CAP FUEL TANK 1 8 A9924800004 FUEL FILTER 1 9 0602125034 FUEL GAUGE CJ 58A 1 10 0605510028 FUEL STRAINER 1 INCLUDES ITEMS W 10 1 0642007810 CUP FILTER FUEL STRAINER 1 10 2 0642006410 PACKING FUEL STRAINER 1 11 0605513169 HOSE 1 12 0605515061 HOSE BAND 2 13 7855525514 RUBBER CUSHION 2 14 7855525604 COLLAR 2 15 0016908030 HEX HEAD BOLT 2 16 0016908020 HEX HEAD BOLT ...

Page 42: ...PAGE 42 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 ROBIN EX170D20210 CRANKCASE ASSY CRANKCASE ASSY ...

Page 43: ...ET 2 210 2771100131 MAIN BEARING COVER C 1 INCLUDES ITEM W 220 0440250210 OIL SEAL 1 230 0600250140 BALL BEARING 6205 1 250 2774500141 GOVERNOR GEAR CP 1 260 2774190103 GOVERNOR SLEEVE 1 270 2776360113 OIL GAUGE 1 275 2776500103 FILLER PLUG 1 280 0213160020 GASKET 1 281 0213160020 GASKET 1 300 0010408350 FLANGE BOLT 6 610 2771300111 CYLINDER HEAD CP 1 INCLUDES ITEM W 620 2771500123 GASKET HEAD 1 6...

Page 44: ...PAGE 44 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 ROBIN EX170D20210 CRANKSHAFT AND PISTON ASSY CRANKSHAFT AND PISTON ASSY ...

Page 45: ...E NUT 1 70 0323030010 WOODRUFF KEY 1 310 2772250110 CONNECTING ROD ASSY 1 INCLUDES ITEMS W 320 2772300103 CONNECTING ROD BOLT 2 350 2772330103 PISTON PIN 1 360 2772340103 PISTON 1 360 2772340303 PISTON OVERSIZE 0 25 MM 1 360 2772340403 PISTON OVERSIZE 0 50 MM 1 370 2772351107 PISTON RING SET 1 370 2772351217 PISTON RING SET OVERSIZE 0 25 MM 1 370 2772351317 PISTON RING SET OVERSIZE 0 50 MM 1 380 0...

Page 46: ...PAGE 46 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 ROBIN EX170D20210 GOVERNOR ASSY GOVERNOR ASSY ...

Page 47: ...4250223 GOVERNOR SPRING 1 80 2764250533 GOVERNOR SPRING 1 310 2774330301 SPEED CONTROL LEVER 1 340 2774350103 STOP PLATE 1 350 0200060170 WASHER 1 355 0217060070 FRICTION WASHER 1 360 0043106250 SCREW 1 365 2374500423 SPRING ADJUST 1 395 2774390203 CLAMP 1 396 0131050030 SCREW WASHER ASSY 1 435 2774600201 SPEED CONT BRKT CP 1 CAN ONLY BE PURCHASED W ITEM 490 440 0043104080 SCREW 1 450 0023506000 S...

Page 48: ...PAGE 48 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 ROBIN EX170D20210 INTAKE AND EXHAUST ASSY INTAKE AND EXHAUST ASSY ...

Page 49: ...73691103 TENTIONER 1 163 2773710103 SPRING TENTIONER 1 166 2773690203 PIN TENTIONER 1 170 2773691313 CHAIN GUIDE 1 200 2773500203 PIN ROCKER 1 210 0031305000 CLIP 1 220 2773620100 ROCKER ARM IN ASSY 1 INCLUDES ITEMW 225 2773620200 ROCKER ARM EX ASSY 1 INCLUDES ITEMW 230 0149050020 ADJUST SCREW 1 240 0170050020 NUT 1 290 0110060020 FLANGE BOLT 1 310 2773011101 MUFFLER SPARK ARRESTOR 1 INCLUDES ITEM...

Page 50: ...PAGE 50 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 ROBIN EX170D20210 AIR CLEANER ASSY AIR CLEANER ASSY ...

Page 51: ...OBIN EX170D20210 AIR CLEANER ASSY AIR CLEANER ASSY NO PART NO PART NAME QTY REMARKS 510 2773262010 AIR CLEANER ASSY LOW PROFILE 1 INCLUDES ITEMSW 510 200 2773261318 BACK PLATE 1 510 220 2773260408 GASKET 1 510 250 2773261228 COVER 1 520 2773261407 ELEMENT ASSY LOW PROFILE 1 ...

Page 52: ...PAGE 52 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 ROBIN EX170D20210 COOLING STARTING ASSY COOLING STARTING ASSY ...

Page 53: ...111 BAFFLE 1 CASE CP 1 61 2775270203 BAFFLE 2 HEAD 1 80 0010406160 FLANGE BOLT 1 81 0110060020 FLANGE BOLT 1 210 2695020130 RECOIL STARTER ASSY 1 INCLUDES ITEM W 210 1 2705011508 SPIRAL SPRING 1 210 2 2695012008 REEL 1 210 3 5825011118 STARTER ROPE 1 210 4 2615010008 STARTER KNOB 1 210 5 2705012508 RATCHET 2 210 6 2275013108 FRICTION SPRING 1 210 11 2695014518 STARTER PULLEY 1 210 35 2705026108 RA...

Page 54: ...PAGE 54 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 ROBIN EX170D20210 CARBURETOR ASSY CARBURETOR ASSY ...

Page 55: ...PROFILE 1 210 7 2776257108 RING LOWER LOW PROFILE 1 210 8 2776256008 CHOKE LEVER 1 210 11 2776253108 THROTTLE SHAFT 1 210 12 2276245108 BOLT 1 210 14 2776250008 NEEDLE 1 210 15 2776251508 PIN 1 210 16 2776250608 FLOAT BODY 1 210 17 2146245008 PACKING 1 210 18 2146254008 CHAMBER PACKING 1 210 19 2266250608 FLOAT ASSY 1 210 20 2776244008 MAIN NOZZLE 1 210 22 2266241108 MAIN JET 77 5 1 210 22 2776241...

Page 56: ...PAGE 56 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 ROBIN EX170D20210 FLYWHEEL ASSY FLYWHEEL ASSY ...

Page 57: ...HEEL ASSY NO PART NO PART NAME QTY REMARKS 10 2777923011 FLYWHEEL CP 1 11 2777943101 IGNITION COIL CP 1 30 0011406250 BOLT WASHER 2 50 27773101H1 WIRE 1 CP 1 60 X660000361 SWITCH ASSY 1 70 0150040090 TAPPING SCREW 2 80 0241070110 GROMMET 1 100 0650140150 SPARK PLUG 1 NGK BR6HS 110 0655000270 SPARK PLUG CAP 1 ...

Page 58: ...PAGE 58 MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 ROBIN EX170D20210 ELECTRIC DEVICE ASSY ELECTRIC DEVICE ASSY ...

Page 59: ...OBIN EX170D20210 ELECTRIC DEVICE ASSY ELECTRIC DEVICE ASSY NO PART NO PART NAME QTY REMARKS 700 2777630111 OIL SENSOR CP 1 705 KU31104311 FLOAT C U CP3 1 740 0011406160 BOLT WASHER ASSY 2 741 0150040090 TAPPING SCREW 1 770 2147900601 CLAMP CP 1 775 0110060020 FLANGE BOLT 1 ...

Page 60: ...ponents f Paint chemicals andlubricants g Decalsandpaperproducts h Itemspurchasedinkits 7 Thesenderwillbenotifiedofanymaterial receivedthatisnotacceptable 8 Suchmaterialwillbeheldforfiveworking days from notification pending instruc tions Ifareplyisnotreceivedwithinfive days thematerialwillbereturnedtothe senderathisexpense 9 Creditonreturnedpartswillbeissuedat dealer net price at time of the orig...

Page 61: ...MQ GA 2 9R A C GENERATOR OPERATION PARTS MANUAL REV 0 10 28 04 PAGE 61 NOTE PAGE ...

Page 62: ...IAL NUMBERON HANDWHENCALLING MULTIQUIP CORPORATE OFFICE 18910 Wilmington Ave 800 421 1244 Carson CA 90746 FAX 310 537 3927 Email mq multiquip com Internet www multiquip com PARTS DEPARTMENT 800 427 1244 FAX 800 672 7877 310 537 3700 FAX 310 637 3284 MAYCO PARTS 800 306 2926 FAX 800 672 7877 310 537 3700 FAX 310 637 3284 SERVICE DEPARTMENT 800 421 1244 FAX 310 537 4259 310 537 3700 TECHNICALASSISTA...

Reviews: