Multiplex RX-5 M-LINK Operating Instructions Manual Download Page 6

 

Operating Instructions for RX-5 M-LINK / 

 

RX-7 M-LINK 2.4 GHz receivers 

Page 16 

Instru

ctions 

for

 RX

-5

/7 M-L

INK

 2.4

 G

H

z r

e

cei

v

er

s  #

 985

 5

312 LA

 30

.09.2014

  • 

 Err

o

rs

 and

 omi

s

sions excep

ted

! •

  

 MU

LTI

P

L

E

X

 

 

 When the Send process is complete, the screen 

displays “--> OK!“ (= complete!). 

  Disconnect the receiver, switch off the 

MULTImate

2.  Activating using the 

MULTIPLEX Launcher

 At 

“More 

settings 

 Options“ / “Weitere Einstellungen 

 

Optionen…“  (= More settings 

 Options) select the 

following menu point:  
“Digital servodata“ / “Digitale Servodaten“  
(= Digital servo data). 

  Click on the “Accept“ / „Übernehmen“ button 

(= Accept). 

  Click on the „Send data“ / “Daten senden“ button 

(= Send data). 

  Click on the “Close“ / “Beenden“ button 

(= Finish). 

 Close 

MULTIPLEX Launcher

, disconnect the receiver. 

3.  Connect the three-core lead (

# 8 5070

) to the receiver’s B/D 

socket. 

4.  Connect the lead to the power supply / servo management 

system, or to the flybarless system (see the operating 
instructions supplied with these devices). 

!

 

Take care to connect the lead correctly, i.e. the con-

nectors must be correctly orientated, and - especially 
when using non-MULTIPLEX products - the pin assign-
ment must be compatible. Be sure to check the symbols 
on the

 M-LINK receiver, and on the non-MULTIPLEX 

product if present. Refer to the operating instructions of 
the non-MULTIPLEX device, and ask the manufacturer if 
you are in any doubt! 

12.

 

S

ELECTING ONE 

S

ENSOR 

A

DDRESS AS

 “P

RIORITY 

A

DDRESS

” 

The telemetry-capable 

RX-5/7 M-LINK

 receivers permit the user 

to define any one of the sensor addresses (0 … 15) as a “priority 
address”: 

This one selected sensor value is then updated at a higher rate 
than all the other sensor values. 

Typical application: “Vario”:  

 

The audio output for climb and descent, and the associated on-
screen display, are updated more frequently than the other 
sensor values, and are therefore generated without delay. 

!

 

Note:

 

The “Priority address” option is switched off by default on M-LINK 
receivers, and can be activated using the 

MULTIPLEX MULTI-

mate

 or the 

MULTIPLEX Launcher

 PC program in conjunction 

with the UNI USB PC lead (

# 8 5149

). 

This is the procedure for activating the priority address: 

1.  Activating using the 

MULTImate

  At the menu point “4-6 Sensor addr.“ / “4-6 Sensoradr.“  

(= Sensor address) select the option:  
“4-6 Prio address“ / “4-6 Prio Adresse“  
(= Priority address). 

  Hold the 3-D digi-adjuster pressed in: 

 

 The 

MULTImate

 displays: “L   0“. 

  Release the 3-D digi-adjuster. 

  Press the 3-D digi-adjuster briefly, and select the priority 

address (0 … 15). 

  Press the 3-D digi-adjuster briefly. 

  Switch to the menu:  

“4-6 Go back …to RX M-LINK“ /  

“4-6 Zurück …zu RX M-LINK“  
(= back … to RX M-LINK) 
and confirm by pressing the 3-D digi-adjuster. 

  Select the menu point: 

“4-10 Send data“ / “4-10 Dat. senden“  
(= Send data) 
and hold the 3-D digi-adjuster pressed in:  

 

 The 

MULTImate

 displays:  

      “please wait…“ / “bitte warten…“ (= please wait). 

  Release the 3-D digi-adjuster: 

 

 When the Send process is complete, the screen 

displays “--> OK!“ (= complete!). 

  Disconnect the receiver, switch off the 

MULTImate

2.  Activating using the 

MULTIPLEX Launcher

  At “Sensor addresses“ / “Sensorparameter“  

(= Sensor address) auswählen:  
“Address w/prio 1:“ / “Adresse mit Prio 1:“ 
(= Address with priority 1). 

  Select the “Address“ / “Adresse“ (= Address) check-box, 

and enter the desired address (0 … 15). 

  Click on the “Accept“ / “Übernehmen“ button 

(= Accept). 

  Click on the “Send data“ / “Daten senden“ button 

(= Send data). 

  Click on the “Close“ / “Beenden“ button  

(= Finish). 

 Close 

the 

MULTIPLEX Launcher

, disconnect the 

receiver.

 

This is the procedure for disabling the priority address: 

1.  Disabling using the 

MULTImate

  At the menu point “4-6 Sensor addr.“ / “4-6 Sensoradr.“  

(= Sensor address) select the option:  
“4-6 Prio address“ / “4-6 Prio Adresse“  
(= Priority address). 

 

!

 

Note:

 

The second line of the screen displays the selected 
priority address. 

  Hold the 3-D digi-adjuster pressed in: 

 

 The screen entry in the second line changes to:  

 “L  off“ / “L   aus“ (= L   off). 

  Switch to the menu:  

“4-6 Go back …to RX M-LINK“ /  
“4-6 Zurück …zu RX M-LINK“  
(= back … to RX M-LINK) 
and confirm by pressing the 3-D digi-adjuster. 

  Select the menu point:  

“4-10 Send data“ / “4-10 Dat. senden“  
(= Send data) 
and hold the 3-D digi-adjuster pressed in:  

 

 The 

MULTImate

 displays:  

 

“please wait…“ / “bitte warten…“ (= please wait). 

  Release the 3-D digi-adjuster: 

 

 When the Send process is complete, the screen 

displays “--> OK!“ (= complete!). 

  Disconnect the receiver, switch off the 

MULTImate

2.  Disabling using the 

MULTIPLEX Launcher

  At “Sensor addresses“ / “Sensorparameter“  

(= Sensor parameters) auswählen:  
“Address w/prio 1:“ / “Adresse mit Prio 1:“ 
(= Address with priority 1). 

  Clear (erase) the tick in the “Address“ / “Adresse“ check-

box (= Address). 

Summary of Contents for RX-5 M-LINK

Page 1: ...Compatible with the MULTImate 8 2094 Integral PC interface Carry out updates and adjustment using the MULTIPLEX Launcher PC program in conjunction with the UNI USB PC lead 8 5149 3 SAFETY NOTES Please...

Page 2: ...r counter or FAIL SAFE settings Press the SET button for 0 5 to 1 second 2 RESET receiver to factory default settings Press the SET button for longer than ten seconds While the SET button is pressed t...

Page 3: ...up again The factory default setting for the HOLD period is 0 75 seconds This period can be adjusted to meet personal requirements using the MULTImate or the PC program MULTIPLEX Launcher FAIL SAFE i...

Page 4: ...nter you will gain the experience required to render the error counter genuinely helpful enabling you to detect changes in good time and to locate indications of possible causes of interference Protra...

Page 5: ...ous M LINK receivers This is the procedure for re activating two receiver mode Note M LINK receivers are set to two receiver mode by default For this reason you can skip steps 1 3 and go directly to s...

Page 6: ...Imate At the menu point 4 6 Sensor addr 4 6 Sensoradr Sensor address select the option 4 6 Prio address 4 6 Prio Adresse Priority address Hold the 3 D digi adjuster pressed in The MULTImate displays L...

Page 7: ...landing If you have encountered problems on a previous flight Important Always ask a second person to help you with your range check so that one of you can secure and observe the model If possible car...

Page 8: ...cost to you By returning your unwanted equipment you can make an important contribution to the protection of the environment 20 GUARANTEE LIABILITY EXCLUSION The company MULTIPLEX Modellsport GmbH Co...

Reviews: