the following facilities: 

  Availability of expanded receiver options, such as freely 

variable HOLD and FAIL-SAFE period, individual FAIL-SAFE 
settings can be activated and adjusted channel by channel, 
… 

  Error counter / error memory read-out:   

The error count can be read out separately for signal errors 
and operating voltage errors. 

  Unrestricted sensor address assignment for the receiver 

battery voltage and for connection quality (0 - 15). 

  Receiver name assignment (max. 12 characters).  

  Switching the following options on and off: “Two-receiver 

mode” (

 11.

) and serial servo output (digital servo data / 

SRXL-MULTIPLEX) (

 12.

). 

  Setting one sensor address as “priority address”:   

The selected sensor value is updated at a higher rate than all 
the other sensor values (

 13.

).  

The 

MULTIPLEX Launcher 

also allows: 

 Firmware 

updates: 

Keep your receiver up-to-date at all times. 

!

 

Note:

 

We recommend that you update your 

MULTImate

 or the 

MULTI-

PLEX Launcher

 at regular intervals to ensure that you can 

exploit all the current features of your receiver and the con-
nected components generally. 

10.

 

T

WO

-R

ECEIVER 

M

ODE

 

What is known as “two-receiver mode” is possible with the 
MULTIPLEX 

RX-5 M-LINK

 and 

RX-7 M-LINK

 2.4 GHz M-LINK 

receivers: 

In this mode 

two 

M-LINK receivers are inter-connected using a 

Diversity lead (

# 8 5070

). 

With this arrangement a total of two or even three receive cir-
cuits operate in parallel: 

The two or three receive circuits incorporated in the two receiver 
cases pick up and analyse the signals (“double diversity” or 
“triple diversity”). This type of diversity can also be described as 
“two-receiver mode”. 

Since the orientation of the two or three receiver aerials is 
different, this arrangement provides a further improvement in 
receive performance, since it minimises directional aerial effects. 
This means that at least one receiver aerial has a “good view” of 
the transmitter regardless of the model’s attitude. Two-receiver 
mode therefore provides a wider safety margin. 

Tip:

 you can also inter-connect different types of M-LINK 

receiver, provided that they are capable of two-receiver mode 
(e.g. 1 x 

RX-16-DR pro M-LINK

 and 1 x 

RX-5 M-LINK

). 

Information concerning suitability for two-receiver mode can be 
found in the operating instructions provided with the various 
M-LINK receivers. 

This is the procedure for re-activating two-receiver mode: 

!

 

Note:

 

M-LINK receivers are set to two-receiver mode by default. For 
this reason you can skip steps 1. – 3. and go directly to step 4. 

1.  Re-activating using the 

MULTImate

  At the menu point “4-7 B/D output“ / “4-7 Ausgabe B/D“  

(= output B/D) select the following option:  
“MPX 2-Receiver“ / “MPX 2-Empfänger“  
(= MPX Two-receiver mode). 

  Select the menu point:  

“4-10 Send data“ / “4-10 Dat. senden“ (= Send data)  
and hold the 3-D digi-adjuster pressed in: 

 

 the 

MULTImate

 displays the following:  

 

“please wait…“ / “bitte warten…“ (= please wait). 

  Release the 3-D digi-adjuster: 

 

 When the send process is complete, the screen  

displays “--> OK!“ (= complete!). 

  Disconnect the receiver, switch off the 

MULTImate

2.  Re-activating using the 

MULTIPLEX Launcher

 At 

“More 

settings 

 Options…“ / “Weitere Einstellungen 

 Optionen…“ (= More settings 

 Options) select the 

following menu point:  
“MULTIPLEX Two-Receiver-Mode“ / “MULTIPLEX Zwei-
Empfänger-Betrieb“  
(= MULTIPLEX two-receiver mode). 

  Click on the “Accept“ / “Übernehmen“ button 

(= Accept). 

  Click on the “Send data“ / “Daten senden“ button 

(= Send data). 

  Click on the “Close“ / “Beenden“ button 

(= Finish). 

 Close

 MULTIPLEX Launcher

, disconnect the receiver. 

3.  You may need to carry out the steps described under 1. or 2. 

on the second M-LINK receiver in order to activate two-
receiver mode. 

4.   Inter-connect the two M-LINK receivers by the B/D sockets 

using the three-cord Diversity lead (

# 8 5070

). Please refer to 

the operating instruction supplied with the Diversity lead. 

!

 

Take care to connect the lead correctly, i.e. the con-

nectors must be correctly orientated, and the pin assign-
ment must be compatible (see symbols on the receiver

)! 

11.

 

S

ERIAL 

S

ERVO 

O

UTPUT 

 

 

 SRXL-MULTIPLEX 

RX-5/7 M-LINK

 receivers offer the facility to use the servo out-

puts as a sum signal (serial servo output = SRXL-MULTIPLEX): 

The receiver’s first twelve channels are carried by a three-core 
lead (

# 8 5070

) via the receiver’s B/D socket. 

Applications: 

  Power supply / servo management systems, or 

  Flybarless systems on model helicopters. 

!

 

Note:

 

SRXL-MULTIPLEX

 is switched off by default on M-LINK recei-

vers, and can be activated using the 

MULTIPLEX MULTImate

 

or the 

MULTIPLEX Launcher

 PC program in conjunction with 

the UNI USB PC lead (

# 8 5149

). 

This is the procedure for activating serial servo output: 

1.  Activating using the 

MULTImate

  At the menu point “4-7 B/D output“ / “4-7 Ausgabe B/D“  

(= Output B/D) select the following option:  
“Digit. Servodata“ / “Dig. Servodaten“  
(= Digital servo data). 

  Select the menu point:  

“4-10 Send data“ / “4-10 Dat. senden“ (= Send data)  
and hold the 3-D digi-adjuster pressed in:  

 

 The 

MULTImate

 screen displays:  

 

“please wait…“ / “bitte warten…“ (= please wait). 

  Release the 3-D digi-adjuster: 

Summary of Contents for RX-5 M-LINK

Page 1: ...Compatible with the MULTImate 8 2094 Integral PC interface Carry out updates and adjustment using the MULTIPLEX Launcher PC program in conjunction with the UNI USB PC lead 8 5149 3 SAFETY NOTES Please...

Page 2: ...r counter or FAIL SAFE settings Press the SET button for 0 5 to 1 second 2 RESET receiver to factory default settings Press the SET button for longer than ten seconds While the SET button is pressed t...

Page 3: ...up again The factory default setting for the HOLD period is 0 75 seconds This period can be adjusted to meet personal requirements using the MULTImate or the PC program MULTIPLEX Launcher FAIL SAFE i...

Page 4: ...nter you will gain the experience required to render the error counter genuinely helpful enabling you to detect changes in good time and to locate indications of possible causes of interference Protra...

Page 5: ...ous M LINK receivers This is the procedure for re activating two receiver mode Note M LINK receivers are set to two receiver mode by default For this reason you can skip steps 1 3 and go directly to s...

Page 6: ...Imate At the menu point 4 6 Sensor addr 4 6 Sensoradr Sensor address select the option 4 6 Prio address 4 6 Prio Adresse Priority address Hold the 3 D digi adjuster pressed in The MULTImate displays L...

Page 7: ...landing If you have encountered problems on a previous flight Important Always ask a second person to help you with your range check so that one of you can secure and observe the model If possible car...

Page 8: ...cost to you By returning your unwanted equipment you can make an important contribution to the protection of the environment 20 GUARANTEE LIABILITY EXCLUSION The company MULTIPLEX Modellsport GmbH Co...

Reviews: