Multiplex RX-5 M-LINK Operating Instructions Manual Download Page 3

 

Operating Instructions for RX-5 M-LINK / 

 

RX-7 M-LINK 2.4 GHz receivers 

Page 13 

Instru

ctions 

for

 RX

-5

/7 M-L

INK

 2.4

 G

H

z r

e

cei

v

er

s  #

 985

 5

312 LA

 30

.09.2014

  • 

 Err

o

rs

 and

 omi

s

sions excep

ted

! •

  

 MU

LTI

P

L

E

X

 

 

The binding procedure runs, the receiver LED 
flashes at high frequency 

 

(LED code 2). 

   

Now release the SET button. 

!

 Note:

 the binding process starts automatically when 

the receiver is used for the first time, and after a RESET - 
even if you have not pressed the SET button. 

2.  Once the transmitter and receiver are bound to each other, 

both switch 

automatically

 to normal operation:

 

 

  The LED on the receiver flashes slowly  

 

 

(LED code 3). 

!

 Note: 

in most cases the binding process only takes a few 

seconds.

 

Binding: locating and correcting faults 

Fault:  

During the binding process the receiver LED continues to flash 
at a high rate after several seconds. 

Cause:  

No M-LINK signal of adequate strength detected. 

Remedy: 

  Reduce the distance between your transmitter and the 

receiver aerial. 

  Ensure that your transmitter is switched ON in binding mode. 

  Repeat the binding procedure. 

Switching the receiver ON and OFF  
in normal operations 

Sequence of switching ON and OFF 

To switch the M-LINK RC system ON, please use this 
procedure: 

1.  Switch the transmitter ON. 

2.  Switch the receiver ON. 

The receiver LED flashes slowly and evenly  
(LED code ): 

 

An M-LINK signal is being received, 

 

the RC system is ready for use. 

To switch the M-LINK RC system OFF, please use this 
procedure: 

1.  Switch the receiver OFF. 

2.  Now switch the transmitter OFF. 

Locating and correcting faults when switching ON 
Fault: 

 

The receiver LED lights up constantly when switched on (LED 
code 1 ), but does not flash. 

Cause:

 

No M-LINK signal detected. 

Remedy: 

  Is the transmitter switched on? 

  Is the transmitter generating an M-LINK signal?  

  Are the transmitter and receiver bound to each other? 

  Have you carried out a receiver RESET? 

  Have you made changes to the setting for “Fast Response”  

or “France mode” ? 

Error: 

The receiver LED stays off after switching on  

 

(LED code 0). 

Cause:

  

The operating voltage (battery voltage) is too low. 

Remedy: 

  Recharge the receiver battery or drive / flight battery. 

HOLD and FAIL-SAFE 

If no signal is picked up, or if the received data is corrupt, the 
last valid information is passed on to the servos in order to 
bridge the signal loss (HOLD mode). 

If interference should occur and FAIL-SAFE has been invoked, 
the servos (...) run to a previously defined position at the end of 
the HOLD period. FAIL-SAFE mode ends as soon as error-free 
signals are picked up again. 

The factory default setting for the HOLD period is 0.75 seconds. 
This period can be adjusted to meet personal requirements 
using the 

MULTImate

 or the PC program 

MULTIPLEX 

Launcher

FAIL-SAFE is switched OFF in the receiver’s default state (as 
delivered), and after a RESET. FAIL-SAFE is activated using the 
SET button on the receiver, or - in the case of certain trans-
mitters - “by radio”. 

If you wish to disable FAIL-SAFE again, the receiver must be 
reset to the default state (RESET). After a RESET you must 
repeat the binding procedure! 

!

 

Note: always activate FAIL-SAFE! 

For safety reasons we recommend that you always activate 
FAIL-SAFE, and ensure that the selected FAIL-SAFE settings 
will cause the model to take up as safe an attitude as possible 
(e.g. motor idle / electric motor OFF, control surfaces neutral, 
landing flaps deployed, tow-release open, …). 

Selecting the FAIL-SAFE settings: 

1.  The receiver LED must not display any errors 

 

(LED code 3). 

 

If it does: switch the receiver OFF, then ON again. 

2   Use your transmitter to move all the servos (and the speed 

controller) to your preferred FAIL-SAFE positions. Press the 
SET button briefly (0.5 to 1 second). The FAIL-SAFE posi-
tions are now stored for all servo channels, and the LED 
flashes the confirmation signal (LED code 5). 

Testing the FAIL-SAFE positions: 

 

Move the sticks to positions other than the FAIL-SAFE settings, 
and then switch the transmitter OFF: the servos should go into 
HOLD mode briefly (0.75 seconds), and then move to the FAIL-
SAFE positions which you previously selected. 

The FAIL-SAFE positions must always be checked and updated 
when necessary, e.g. when you install the receiver in a new 
model. 

!

 

Checking the FAIL-SAFE function: 

For testing the FAIL-SAFE function only, the receiver can be 
operated with the transmitter switched off. Caution: if the FAIL-
SAFE settings are incorrect, the motor could burst into life: injury 
hazard! 

After sixteen seconds in FAIL-SAFE mode no further signals are 
sent to the servos (default setting; this period can be altered 
using the 

MULTImate

 or the 

MULTIPLEX Launcher

Analogue servos and some digital servos (see instructions) then 
become “soft”, to avoid them being stalled. Modern speed con-
trollers switch themselves off. However, some digital servos 
remain “hard” and maintain their last position. 

The FAIL-SAFE function can be activated and disabled servo by 
servo using the 

MULTImate 

or the 

MULTIPLEX Launcher

Example: throttle only to Idle / OFF, all other servos = HOLD. 

RESET to factory default settings 

The receiver settings can be reset to the factory default settings. 
If you do this, all the settings you have entered, such as binding 
information, FAIL-SAFE settings ... are lost permanently. 

Summary of Contents for RX-5 M-LINK

Page 1: ...Compatible with the MULTImate 8 2094 Integral PC interface Carry out updates and adjustment using the MULTIPLEX Launcher PC program in conjunction with the UNI USB PC lead 8 5149 3 SAFETY NOTES Please...

Page 2: ...r counter or FAIL SAFE settings Press the SET button for 0 5 to 1 second 2 RESET receiver to factory default settings Press the SET button for longer than ten seconds While the SET button is pressed t...

Page 3: ...up again The factory default setting for the HOLD period is 0 75 seconds This period can be adjusted to meet personal requirements using the MULTImate or the PC program MULTIPLEX Launcher FAIL SAFE i...

Page 4: ...nter you will gain the experience required to render the error counter genuinely helpful enabling you to detect changes in good time and to locate indications of possible causes of interference Protra...

Page 5: ...ous M LINK receivers This is the procedure for re activating two receiver mode Note M LINK receivers are set to two receiver mode by default For this reason you can skip steps 1 3 and go directly to s...

Page 6: ...Imate At the menu point 4 6 Sensor addr 4 6 Sensoradr Sensor address select the option 4 6 Prio address 4 6 Prio Adresse Priority address Hold the 3 D digi adjuster pressed in The MULTImate displays L...

Page 7: ...landing If you have encountered problems on a previous flight Important Always ask a second person to help you with your range check so that one of you can secure and observe the model If possible car...

Page 8: ...cost to you By returning your unwanted equipment you can make an important contribution to the protection of the environment 20 GUARANTEE LIABILITY EXCLUSION The company MULTIPLEX Modellsport GmbH Co...

Reviews: