![Multimetrix DMM 107 User Manual Download Page 28](http://html1.mh-extra.com/html/multimetrix/dmm-107/dmm-107_user-manual_1854514028.webp)
28
7.4 Measuring 400 mA Current (and Frequency)
Read the safety guidelines before use.
Autoranging or manual ranging: 40 mA and 400 mA AC and DC
(2 ranges).
1.
Set the switch to 400 mA.
2.
Press the FUNC. key to measure an alternating current.
3.
Read the value of the current once it has stabilised.
The
symbol indicates a reversal of polarity of the probes.
"OL" indicates an overrange.
Press the Hz key to change successively to frequency
measurements, then cyclical ratio measurements, before returning
to AC voltage measurements.
7.5 Measuring 10 A Current
Read the safety guidelines before use.
Never work on circuits that are not protected against
overvoltages above 10 A (by fuses or circuit breakers).
Measuring ranges: 10 A
AC
and A
DC
(1 range).
1.
Set the switch to 10A.
2.
Press the FUNC. key to measure an alternating current.
3.
Read the value of the current once it has stabilised.
The
symbol indicates a reversal of polarity of the probes.
"OL" indicates an overrange.
7.6 Resistance Measurements
Read the safety guidelines before use. The circuit must
be without power.
Automatic or manual measurement ranges: 400
Ω
to 40 M
Ω
(6 ranges).
Set the switch to
. "OL" indicates an overrange.
Summary of Contents for DMM 107
Page 7: ...7 Utilisation 6 Pr sentation 6 1 Face avant 9 3 4 8 1 2 5 6 7 10...
Page 9: ...9 6 2 Face arri re...
Page 24: ...24 Use 6 Presentation 6 1 Front Panel 9 3 4 8 1 2 5 6 7 10...
Page 26: ...26 6 2 Rear Panel...
Page 41: ...41 Benutzung des Ger ts 6 Ger tevorstellung 6 1 Frontseite 9 3 4 8 1 2 5 6 7 10...
Page 44: ...44 6 2 Ger ter ckseite...
Page 52: ...52 Abnehmbare Pr fspitzenbeleuchtung Best Nr P06239301...
Page 61: ...61 Utilizzo 6 Presentazione 6 1 Lato anteriore 9 3 4 8 1 2 5 6 7 10...
Page 63: ...63 6 2 Lato posteriore...
Page 79: ...79 Utilizaci n 6 Presentaci n 6 1 Cara anterior 9 3 4 8 1 2 5 6 7 10...
Page 81: ...81 6 2 Cara posterior...