Getting started: making AC supply connections

 

 

 

 

 

 

Risk of fire / Safety risk 
 

The CoboPin-VT3001C requires an AC power source with sufficient 
power carriage and correct grounding to ensure safe operation. The AC 
power source must be equipped with a circuit breaker and earth 
leakage detector. Make sure to only use compliant AC supply lines.  
 
 

 

 

Getting started: making DMX control connections

 

 
Connect the CoboPin-VT3001C to a suitable DMX controller where needed, and 
interconnect several units by means of their DMX In/Outputs as required. The last unit 
shall be equipped with a proper 120 Ohm termination resistor equipped DMX-plug as 
shown in below drawing. Please make sure that all used DMX cables comply to below 
standard: 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

User Manual: CoboPin-VT3001C(-I/-T)                                  

 

 

 

V1.00 (10-2013)                                                                                                                                                

9

 

 

Operation

 

 
VT3001-I (install version) 

 

 
VT3001-T (touring version) 

 

Summary of Contents for COBOPIN-VT3001C-I

Page 1: ...upply type max consumption switch mode 29W DMX connections 3 pin XLR Male Female Modulation Type Pulse Density Modulation PDM Dimensions without bracket WxHxD 100 0 x 99 0 x 202 0mm Dimensions with br...

Page 2: ...ant safety information on the product and in this manual WARNING Read manual before installation operation or servicing WARNING Safety hazard Risk of injury or death WARNING Hazardous voltage Risk of...

Page 3: ...alue 50 to very fast value 255 If channel 4 reaches a DMX value of 50 or above a tact function will be added to the chases The tact speed can be adjusted from slow value 50 to 23 pulses per second val...

Page 4: ...unit is protected from vibration and where a fixed mounting position is provided In case of overhead mounting follow applicable rigging requirements 3 Before plugging the AC cord in the wall outlet c...

Page 5: ...s of EN60950 Do not touch heat sink areas of the device during operation and allow 20 minutes of cool down time after powering off before touching 5 If fluids have spilled into the unit or small parts...

Page 6: ...0 2013 11 Description Function of Knob 1 A 0 All off none A 1 Static scene Colour A 2 Soft fade red green Speed A 3 Soft fade green blue Speed A 4 Soft fade red blue Speed A 5 Soft fade red yellow Spe...

Page 7: ...d secure mounting The CoboPin VT3001C can be positioned for operation in various ways Floor standing operation only T touring version Turn the bracket to the lower side of the unit Separate the two sp...

Page 8: ...ke sure to only use compliant AC supply lines Getting started making DMX control connections Connect the CoboPin VT3001C to a suitable DMX controller where needed and interconnect several units by mea...

Reviews: