12

 

Available colour presets: 
 

C 0 

all off 

C10 

Frog 

C 1 

Red 

C11 

Lavender 

C 2 

Green 

C12 

Candy 

C 3 

Blue 

C13 

Peach 

C 4 

Yellow 

C14 

Aqua 

C 5 

Pink 

C15 

Leaf 

C 6 

Turquoise 

C16 

Purple 

C 7 

Lime 

C17 

Barbie 

C 8 

Orange 

C18 

Breeze 

C 9 

Marine 

C19 

White 

 

“d3” Mode (DMX 3-Channel RAW Mode) 

 

Press the MODE button (7) until the display shows “d3”, indicating operation in “d3” (3-
channel DMX) mode. Shortly after that, the display shows the DMX starting address. 
You can choose any DMX starting address by simply using the UP/DOWN buttons 
(5/6). The chosen DMX-address comes effective approximately 3 seconds later and will 
show up on the display (2) in alternation to the “d”. This allows control of the unit by any 
external DMX signal sending on the chosen channel. In this mode the potentiometer (1) 
is disabled. 
 
The unit receives DMX values on a packet of three channels and mirrors the received 
data on the DMX output (9). If a DMX signal is present the DMX LED (3) will turn on. 
The three channels control the unit as follows:  
 

DMX channel 

Value Range

Function 

CH1  

000-255 

Red Intensity 

CH2 000-255  Green 

Intensity 

CH3 000-255  Blue 

Intensity 

 
This setting is stored even if the device is switched off.  
Note: For master/slave operation, the slave units shall be set to “d3” mode.  

 

“d4” Mode (DMX 4-Channel Combined Master/Strobe Mode) 

 
Press the MODE button (7) until the display shows “d4”, indicating operation in “d4” (4-
Channel DMX) mode. Shortly after that, the display shows the DMX starting address. 
You can choose any DMX starting address by simply using the UP/DOWN buttons 
(5/6). The chosen DMX-address comes effective approximately 3 seconds later and will 
show up on the display (2) in alternation to the “d”. This allows control of the unit by any 
external DMX signal sending on the chosen channel. In this mode the potentiometer (1) 
is disabled. 
 

User Manual: CoboPin-VT3001C(-I/-T)                                  

 

 

 

V1.00 (10-2013)                                                                                                                                                

5

 

4.  The surface of the device may get hot during operation, and heat 

sink areas may reach to or exceed the limits of EN60950. Do not 
touch heat sink areas of the device during operation, and allow 20 
minutes of cool-down time after powering off before touching. 

5.  If fluids have spilled into the unit or small parts have intruded the 

unit, immediately switch off the unit and hand it over to the 
authorized service for a security check. 

6.  Disconnect the unit from AC supply by pulling the AC plug out of 

the wall outlet or the unit’s AC socket during a thunder-storm in 
order to avoid any damage on the unit due to AC voltage peaks. 

7.  In cause of not correct function of this unit or damaged AC cord or 

other damaged parts, pull immediately the AC plug out of the wall 
outlet and hand the unit over to the authorized service for a 
security check.  

8.  To meet all aspects of functionality and security during mainte-

nance work to be preformed on this unit, all parts should be 
replaced by genuine spare parts. Consequently, take care of your 
dealer or maintenance company to be authorized by the 
manufacturer. 

 

 

Health advice

 

 
This unit produces and absorbs electromagnetic radiation. The strength of radiation and 
the sensitivity for disturbing interference matches the CE and FCC requirements. A 
corresponding sign is printed on the backside of the unit. Any change or modification 
may affect the behavior of the unit concerning electromagnetic radiation, with the CE 
requirements eventually not to be met any more. The manufacturer takes no 
responsibility in this case. 
 

 

Functional advice

 

 
This unit is immune to the presence of electromagnetic disturbances – both conducted 
and radiated - up to a certain level. Under peak conditions, the unit is classified to show 
a “class C” performance criteria and may encounter temporary degradation or loss of 
function which may need manual help to recover. In such case, disconnect the AC 
power from the unit and reconnect it again to recover.  
 

 

Environmental advice

 

 

 

This unit is built to conform to the ROHS standards and the WEEE 
directive 2002/96/EC of the European Parliament and of the Council of 
the European Union. Under these regulations, the product shall not be 
discarded into regular garbage at the end of its life, but shall be returned 
to authorized recycling stations. 

 
 

Summary of Contents for COBOPIN-VT3001C-I

Page 1: ...upply type max consumption switch mode 29W DMX connections 3 pin XLR Male Female Modulation Type Pulse Density Modulation PDM Dimensions without bracket WxHxD 100 0 x 99 0 x 202 0mm Dimensions with br...

Page 2: ...ant safety information on the product and in this manual WARNING Read manual before installation operation or servicing WARNING Safety hazard Risk of injury or death WARNING Hazardous voltage Risk of...

Page 3: ...alue 50 to very fast value 255 If channel 4 reaches a DMX value of 50 or above a tact function will be added to the chases The tact speed can be adjusted from slow value 50 to 23 pulses per second val...

Page 4: ...unit is protected from vibration and where a fixed mounting position is provided In case of overhead mounting follow applicable rigging requirements 3 Before plugging the AC cord in the wall outlet c...

Page 5: ...s of EN60950 Do not touch heat sink areas of the device during operation and allow 20 minutes of cool down time after powering off before touching 5 If fluids have spilled into the unit or small parts...

Page 6: ...0 2013 11 Description Function of Knob 1 A 0 All off none A 1 Static scene Colour A 2 Soft fade red green Speed A 3 Soft fade green blue Speed A 4 Soft fade red blue Speed A 5 Soft fade red yellow Spe...

Page 7: ...d secure mounting The CoboPin VT3001C can be positioned for operation in various ways Floor standing operation only T touring version Turn the bracket to the lower side of the unit Separate the two sp...

Page 8: ...ke sure to only use compliant AC supply lines Getting started making DMX control connections Connect the CoboPin VT3001C to a suitable DMX controller where needed and interconnect several units by mea...