Multiform COBOPIN-VT3001C-I User Manual Download Page 4

User Manual: CoboPin-VT3001C(-I/-T)                                  

 

 

 

V1.00 (10-2013)                                                                                                                                                

4

 

 

 

Protection from electric shock: 

1.  Only connect this unit to a mains socket outlet with protective earth 

connection, ground-fault (earth-fault) and overload protection.  

2.  Where the mains plug or an appliance coupler is used as a dis-

connect device, such device shall remain readily operable.  

3.  To pull the AC Cord out of the wall outlet or the unit’s AC socket, 

never pull the cable itself, but only the AC plug.  

4.  Disconnect the unit from AC supply before any kind of cleaning on 

the product. Use smooth and dry cloth only for cleaning.  

5.  Do not expose this unit to any dripping or splashing liquids, and do 

not place objects filled with liquids, such as vases, on the unit.  

6.  Do not operate this unit near to open water or in high humidity.  
7.  Choose the position of the AC cord according to the lowest risk of 

damage by foot steps or by squeezing it.  

8.  Do not open the unit for service, there are no user-serviceable 

parts inside. Warranty will be void in any case of unauthorized 
service by the user or other not authorized persons.  
 

 

 

Protection from fire:

1.  Take care of not placing the unit near sources of heat (e.g. 

powerful amplifiers, fog machines). 

2.  Allow at least about 0.15m (6 ins.) between this unit and other 

devices or a wall to allow for proper cooling. 

3.  Take always care of sufficient air convection in the unit’s 

environment to avoid overheating. Make sure air convection slots 
are not blocked. Do not operate this unit in environmental 
temperatures exceeding 40 degrees Celsius.  

4.  Be sure this fixture is kept at least 0.75m (30ins.) away from any 

flammable materials (decoration etc.).  

5. 

Do not stick filters, masks or other materials directly on the LEDs or 
the LED cover screen. 

 

6.  Check the total maximum power of your AC wall outlet if you 

connect several units to one wall outlet and avoid any overloading. 

7.  If the device itself has an AC outlet for providing power to other 

units, make sure to not exceed the specified maximum load. 
 

 

 

Protection from injury and damage: 

1.  Never use any accessories or modifications not authorized by the 

manufacturer of this unit. 

2.  Choose a location for operation where the unit is protected from 

vibration and where a fixed mounting position is provided. In case 
of overhead-mounting, follow applicable rigging requirements.  

3.  Before plugging the AC cord in the wall outlet, check whether the 

AC plug, the mains voltage and frequency are the same as this 
product is specified for. If not, contact you dealer immediately. 

User Manual: CoboPin-VT3001C(-I/-T)                                  

 

 

 

V1.00 (10-2013)                                                                                                                                                

13

 

The unit receives DMX values on a packet of four channels and mirrors the received 
data on the DMX output (9). If a DMX signal is present the DMX LED (3) will turn on. 
The four channels control the unit as follows:  
 

DMX channel

Value Range

Function

CH1  

000-255 

Red intensity 

CH2 000-255  Green 

intensity 

CH3 000-255  Blue 

intensity 

CH4 000-127  Master 

dimmer 

 

128-227 

Strobe (128=slow / 227=max. speed 23 Hz) 

 

228-255 

Master dimmer full on, Strobe off 

 
This setting is stored even if the device is switched off.  

“d5” Mode (DMX 5-Channel Split Master/Strobe Mode)

 

 
Press the MODE button (7) until the display shows “d5”, indicating operation in “d” 
(DMX) mode. Shortly after that, the display shows the DMX starting address. You can 
choose any DMX starting address by simply using the UP/DOWN buttons (5/6). The 
chosen DMX-address comes effective approximately 3 seconds later and will show up 
on the display (2) in alternation to the “d”. This allows control of the unit by any external 
DMX signal sending on the chosen channel. In this mode the potentiometer (1) is 
disabled. 
 
The unit receives DMX values on a packet of five channels and mirrors the received 
data on the DMX output (9). If a DMX signal is present the DMX LED (3) will turn on. 
The five channels control the unit as follows:  
 

DMX channel

Value Range

Function

CH1  

000-255 

Red Intensity 

CH2 000-255  Green 

intensity 

CH3 000-255  Blue 

intensity 

CH4 000-255  Master 

dimmer 

CH5 

000-255 

 000…049 Strobe off, 050…255 Strobe rate 
(050=slow / 255=max. speed 23 Hz) 

 
This setting is stored even if the device is switched off.  

 

“P” DMX Preset Mode 

 
If you want to run the pre-programmed patterns and scenes by an external DMX-
controller you can use the DMX Preset Mode. Press the MODE button (7) until the 
display shows “dP”, indicating operation in “P” (DMX Preset) mode. Set the DMX 
starting address by simply using the UP/DOWN buttons (5/6). The chosen DMX-
address comes effective approximately 3 seconds later and will show up on the display 
(2) in alternation to the “dP”. 
 

Summary of Contents for COBOPIN-VT3001C-I

Page 1: ...upply type max consumption switch mode 29W DMX connections 3 pin XLR Male Female Modulation Type Pulse Density Modulation PDM Dimensions without bracket WxHxD 100 0 x 99 0 x 202 0mm Dimensions with br...

Page 2: ...ant safety information on the product and in this manual WARNING Read manual before installation operation or servicing WARNING Safety hazard Risk of injury or death WARNING Hazardous voltage Risk of...

Page 3: ...alue 50 to very fast value 255 If channel 4 reaches a DMX value of 50 or above a tact function will be added to the chases The tact speed can be adjusted from slow value 50 to 23 pulses per second val...

Page 4: ...unit is protected from vibration and where a fixed mounting position is provided In case of overhead mounting follow applicable rigging requirements 3 Before plugging the AC cord in the wall outlet c...

Page 5: ...s of EN60950 Do not touch heat sink areas of the device during operation and allow 20 minutes of cool down time after powering off before touching 5 If fluids have spilled into the unit or small parts...

Page 6: ...0 2013 11 Description Function of Knob 1 A 0 All off none A 1 Static scene Colour A 2 Soft fade red green Speed A 3 Soft fade green blue Speed A 4 Soft fade red blue Speed A 5 Soft fade red yellow Spe...

Page 7: ...d secure mounting The CoboPin VT3001C can be positioned for operation in various ways Floor standing operation only T touring version Turn the bracket to the lower side of the unit Separate the two sp...

Page 8: ...ke sure to only use compliant AC supply lines Getting started making DMX control connections Connect the CoboPin VT3001C to a suitable DMX controller where needed and interconnect several units by mea...

Reviews: