MultiDyne HUT-APE User Manual Download Page 8

 

 

SILVERBACK APE

 

– Green LED indicating the Multidyne Advanced Power Extender (APE) is 

connected to the SMPTE output. 

GRASS VALLEY

 

– Green LED indicating a Grass Valley LDX camera is connected to the SMPTE 

output. 

SONY

 

– Green LED indicating a Sony 1K, 2K, 3K or 4K series camera is connected to the SMPTE 

output. 

PANASONIC AK-HC3900

 

– Green LED indicating a Panasonic AK-HC3900 camera is connected 

to the SMPTE output. See 

Section 7

 for reference on the note about 

Fiber I/O

 

C.  Status Indicators 

HIGH VOLTAGE

 

– This indicator is off when the HUT-APE is in the start-up/standby mode (i.e., low 

voltage output), lights up green when the camera is connected with its power switch in the ON 
position, and red if the high voltage is on but the output voltage is lower than the specified operating 
range. 

Each of the camera systems, as well as the Multidyne APE power supply, initially power-up using a 
low voltage in the 15 

– 45 VDC range to operate low power detection and startup circuitry providing 

a handshake between the camera and the CCU thereby establishing a valid connection. 

CAMERA PSU

 

– Lights up red when no communication has been established between the HUT-

APE and one of the above compatible devices or green when a functional link is detected. 

AC BACKUP READY/ON

 

– Off if no secondary/backup source is present; lights up green when the 

HUT-

APE is operating on the main power source with the backup power source present (“normal” 

dual AC source operating mode), lights red when the main power has dropped/failed with the unit 
now relying on the backup power source, and then alternates between red and green when the 
main power source is re-applied, and monitored for 30 seconds to verify stability before another 
seamless transition back to the main power source; in which case the LED returns to solid green. 

The HUT-

APE is equipped with “Main” and “Backup” AC inlets that provides seamless transition to 

a secondary AC mains power source in case the main power source either drops below the 
specified operating voltage range of the HUT-APE (brown-out condition) or fails completely. No 
variation in the HUT-APE output voltage will occur, thereby maintaining glitch-free video/sound 
performance from the connected camera system. 

OVERLOAD

 

– Off under normal operating conditions, lights up red when the HUT-APE output is 

loaded beyond 90% of the total output rating, and flashes between red and orange if the over-
current detection has been triggered, placing the HUT-APE in the 20 second retry interval cycle. 

OVER TEMP

 

– This Indicator displays multiple fault conditions related to the cooling of the HUT-

APE 

1. Locked rotor indication 

– If the rotor is locked by an obstruction or failure of the motor, the 

LED will light red. 

2. Internal overheating 

– If the internal operating temperature exceeds a safe limit for the 

electronic components, the LED will flash red as the HUT-APE enters a 2-minute shutdown 

Summary of Contents for HUT-APE

Page 1: ......

Page 2: ...iptions 7 3 HUT BS CCU Side 13 4 SilverBack APE 14 5 Applications 15 6 Moving the Fiber Plate 16 7 Panasonic Fiber I O 18 8 Accessories 20 9 Troubleshooting Error Bookmark not defined 10 Specification...

Page 3: ...Declaration of Conformity...

Page 4: ...Safety Info...

Page 5: ...ver look directly into the end of the optical fiber while either end of the system is operating Warning Never clean an optical fiber connector on equipment or cable that is carrying light Warning Alwa...

Page 6: ...ich takes these two fibers and routes them to a SMPTE hybrid fiber connector It also plugs into local mains power and injects various DC voltage for your camera into that same SMPTE connector which no...

Page 7: ...t voltage on or off based solely on the sense line control signals from the camera B MODE Upon power up or whenever the unit is powered on with no SMPTE cable attached the HUT APE enters the search mo...

Page 8: ...rating on the main power source with the backup power source present normal dual AC source operating mode lights red when the main power has dropped failed with the unit now relying on the backup powe...

Page 9: ...ut enabled Each of the internal conductors are monitored the red and gray sense wires the black and white power wires and the ground shield When a fault is detected in the standby startup mode low vol...

Page 10: ...ay change as the range of optical power from overload 0 dBm to minimum detectable signal 21 dBm changes Optical power greater than 0 dBm will cause all the LEDs to blink red Optical power less than 21...

Page 11: ...ront panel to conveniently handle various installation requirements See the Moving the Fiber Plate section for details G Lemo SMPTE 304M Plug FXW 3K 93C Power Supply Output Connect directly to camera...

Page 12: ...ed fiber cables between the fiber connector s on HUT BS and the dry fiber connector s on the HUT APE D HYBRID FIBEROPTIC SMPTE ST 311 CABLE Connect a length of hybrid fiber cables between the HUT APE...

Page 13: ...the camera It has 2 LEDs located on the panel with the ST connectors labeled Power and HV The Power LED is green the CCU is supplying power to the HUT BS and the HUT BS is attempting to spoof the CCU...

Page 14: ...4 SilverBack APE Future model...

Page 15: ...5 Applications A HDTV SMPTE Camera B SMPTE Hybrid Cable Up to 3km C HUT APE D Singlemode fiber E HUT BS F SMPTE Hybrid Cable G Camera Controller Unit CCU...

Page 16: ...s before closing the enclosure Recommended product Permatex 24010 Medium Strength Thread Locker Blue Gel 1 Unplug the HUT APE power cable s and all connected fibers Let unit sit for 20 minutes for int...

Page 17: ...he internal fibers from their original position to the new fiber plate location 7 Connect the fibers to the same corresponding ports noted in Step 4 8 Attach fiber plate and blank plates in the revers...

Page 18: ...med in an ESD safe environment Use caution not to touch any internal components Do not contact any fiber optic connector end faces Note Apply medium strength thread locker on screws before closing the...

Page 19: ...3 Swap both fiber pairs connected in the quad LC coupler Before Default After Panasonic 4 Reinstall top cover...

Page 20: ...CP J48 KIT HUT APE Rackmount Kit The optionally available HUT Ears allow up to three 3 HUT APE units to be mounted into a standard 19 rack Each HUT APE takes 2RU height and 1 3rd RU width Includes all...

Page 21: ...Fiber Plate Options HUT APE U2 SPP LC2XXF LC UPC HUT APE U2 SPP SC2XXF SC UPC HUT APE U2 SPP ST2XXF ST UPC HUT APE U2 SPP OC2XXF Neutrik opticalCON Duo...

Page 22: ...9 Specifications 9 1 Unit Dimensions Weight HUT APE W x H x D 146mm x 88mm x 266mm 5 75 x 3 45 x 10 5 in 7 5 lbs HUT BS W x H x D 178mm x 64mm x 51mm 7 x 2 5 x 2 inches 0 7 lbs...

Page 23: ...150 Fiber Type Singlemode Fiber Polish Ultra physical contact UPC Fiber Connectors LC ST SC or Neutrik opticalCon DUO Optical Power Meter Accuracy 2dB HUT APE Input 95 250 VAC 5 2A 47 63Hz HUT APE Pow...

Page 24: ...SONY HDC 1500 HDC 1700 HDC 2000 HDC 2400 HDC 2500 HDC 2570 HDC 3100 HDC 3170 HDC 3500 HDC 4300 HDC 4800 HDC 5500...

Page 25: ...Contact Info Contact support multidyne com...

Page 26: ...Copyrights opticalCON is registered trademarks of NEUTRIK AKTIENGESELLSCHAFT...

Reviews: