28
Chapter 4 Comparator Function
4.1 Overview
The battery measurement values can be compared with the present threshold values using
the comparator function to determine the ranges in which the values fall within: PASS, or
FAIL. Up to 200 comparator conditions can be set.
A buzzer sounds when the test result is not qualified in the range.
4.2 Turning On the Comparator Function
1.Press
[SET]
on the test page. Switch to the comparator interface.
2.
Press the
/
/
keys to move the cursor to the comparator switch position,
press
[ENTER]
to select the comparator switch, and then press the
/
keys to set the
comparator ON or OFF.
4.3 Select comparison mode
1. Press
[SET]
on the test page. Switch to the comparator interface.