background image

  2. SPECIFICATIONS                                                                                                         

 

 

Measuring Method 

:Dual integration mode 

Measuring Function 

:AC Current by clamping CT 

Display 

:3.5 digit LCD, max. 1999 count 

Measuring Range 

: 0-2000mA/20A (50/60Hz), two range manual 

 

Accuracy 

:23

o

C±5

 o

C , 80%RH or less 

 

Range 

Resolution 

Accuracy 

2000mA 

1mA 

±2% rdg±8dgt 

20A 

0.01A 

 

 
Jaw Opening Capability: 

 
:

φ

35mm 

Overload Indication: 

:Blanking of all digits except MSD 1 

Data Hold 

:“DH” mark on the display for holding measured data 

Low Battery Indication 

:“B” mark on LCD readout 

Sampling 
Auto Power Off 

:2 times/second 
:approx. 5 minutes after power on 

Operation Circuit Voltage 

:AC 80V – 7000V 

Insulation Resistance 

:100M ohm or more (between handle and CT core) 

Withstanding Voltage 

:AC 15KV, 1 minute (between handle and CT core) 

Power Supply 

:UM-3 (1.5V) x 2 pcs. 

Operating Temperature 
Storage Temperature 

:0~40

℃ 

less than 80%RH without condensation 

:-10

~60

  less than 80%RH without condensation 

Dimension 
Weight 

:70(W)x356(H)x32(D)mm 
:Approx. 370 g (including batteries) 

 
Accessories 

 
Carrying case………….1 
Instruction Manual…...1 
Batteries………….…….2 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Reviews: