MULTI MEASURING INSTRUMENTS MCL-550D Instruction Manual Download Page 6

 
 
 
 
 
 
 

 

!

WARNING 

    Do not make measurements of power lines carrying more than 250V. 
    IN  SOME  CASES,  POWER  LINES  MAY CARRY VOLTAGE  SPIKES  OF 

SEVERAL  TIMES  OF  THE  NORMAL  SUPPLY  VOLTAGE.  THIS 
INSTRUMENT SHOULD NOT BE USED TO MEASURE POWER LINES. 
*  The  term  of  “POWER  LINE”  means  the  electrical  circuit  providing  the 

power to factories, buildings, and etc. 

 

!

WARNING 
POSSIBLE ELECTRICAL SHOCK. Do not make measurements if the case 
is damaged or the rear case is removed. Remove all electrical inputs before 
removing the rear case. 

 

!

WARNING 
POSSIBLE ELECTRICAL SHOCK or FIRE HAZARD. Do not expose this 
tester  to  rain  or  moisture.  Do  not  operate  the  tester  in  the  presence  of 
flammable gases or fumes. 

 

!

CAUTION 

    To  avoid  damage  to  the  tester,  disconnect  test  leads  before  changing 

functions. Do not exceed the maximum input limits. 

 

                                                                                                 
 

 

4-3. Measurement of Resistance and Continuity Check

 

 
 

① 

Set the power switch to "ON" position.   

② 

Connect the plug of red test lead into 

the “

Ω

” terminal and the plug of black   

test lead into the “COM” terminal. 

③ 

Set the range selector switch to “

Ω

” or 

)

)

)

 2K 

Ω

” range. 

④ 

Contact the tips of the test leads to the 
circuit under test. 

⑤ 

Read the resistance value in the display.                                                 
In continuity check, if the circuit under test has a resistance of less 
than approximately 300

Ω

, the continuity beeper will sound.                                           

 

                                                                                                           

                                                                                                                                 

 

!

CAUTION 
Be sure all voltage is turned OFF in the circuit before making resistance 
measurement. 

 

Summary of Contents for MCL-550D

Page 1: ...anical electronic design Before you use your new instrument read this Instruction Manual completely and familiarize yourself thoroughly with all functions Keep this manual carefully to take out whenev...

Page 2: ...operations WARNING POSSIBLE ELECTRICAL SHOCK This instrument is for the use of low voltage circuit Do not make measurements in the circuit more than AC 600V Before use check and confirm the voltage o...

Page 3: ...f mode approx 10 minutes after the power switch on Operating temperature 0 to 40 80 RH non condensing Strange temperature 10 to 60 70 RH non condensing Power supply 1 5V AAA size R03 x2 Power consumpt...

Page 4: ...where it is difficult to see the readings use the data hold switch Fig 1 Note Clamp around only one conductor of the circuit to be measured See Fig 1 When making the clamp measurements for high AC cur...

Page 5: ...tion Connect the plug of red test lead into the V terminal and the plug of black test lead into the COM terminal Set the range selector switch to ACV range Contact the tips of the test leads to the ci...

Page 6: ...to rain or moisture Do not operate the tester in the presence of flammable gases or fumes CAUTION To avoid damage to the tester disconnect test leads before changing functions Do not exceed the maximu...

Page 7: ...e displayed CAUTION Be sure all voltage is turned OFF in the circuit before making diode test 5 REPLACEMENT OF BATTERIES When the battery voltage falls below a specified voltage value the B mark will...

Page 8: ...ent out from our factory after the sufficient internal inspections but if you find any defect due to the fault in our workmanship or the original parts please contact the dealer where you bought the i...

Reviews: