2. SPECIFICATIONS 
 

Safety standard : Meets the requirements for double insulation to IEC 1010-2-032, 

IEC  61010-1,  IEC  61010-2-032  installation  Category

600V 

phase to earth. 

E.M.C. standard : The instrument meets EN 61326-1/-2-2 and EN 61000-4-2/-3 
Withstanding voltage : AC 5500V, 1 minute (between outer case and core of CT)     
Measuring method : Dual integration mode 
Jaw opening capability : 55mm

φ

 

Display : 3 1/2 digit LCD max. reading of 1999 and annunciators 
Over range indication : Blanking of all digits except MSD1   
Low battery indication : "B" mark on LCD readout 
Sampling : 2 times/s 
Data hold indication : "D

H" mark on LCD readout 

Auto power off : The meter is set to power off mode approx. 10 minutes after the 

power switch on. 

Operating temperature : 0

  to 40

80%RH (non-condensing) 

Strange temperature :

10

  to 60

70%RH (non-condensing) 

Power supply : 1.5V (“ AAA” size, R03) x2 
Power consumption and battery life : Approx. 5mW, 500 hours continuous. 
Size : 85(W)x240(H)x34(D)mm 
Weight : Approx. 350g   
Accessories : Carrying case…………..1 

Instruction manual……1 
Batteries…………………2 
Test lead…………………1set 
 
 

Measuring range (23

℃±

5

80% RH ) : 

 
 
 
 
 

Range 

Accuracy 

Max. input 

~A 

(50/60Hz) 

Manual range 

20A 

±

1.2% rdg

±

10 dgt 

 

AC2000A 

 

200A 

 

2000A 

±

1.2% rdg

±

8 dgt 

~V 

(50/60Hz) 

… V 

Auto range 

2V 

±

0.7% rdg

±

5 dgt 

 

AC/DC 

750V rms 

20V 

±

1.2% rdg

±

5 dgt 

200V 

 

750V 

 

 

 

Ω

 

(OHM) 

 

Auto range 

200

Ω

 

±

1.2% rdg

±

5 dgt 

Input protection 

2K

Ω

 

 

250V rms 

20K

Ω

 

 

200K

Ω

 

 

2000K

Ω

 

 

20M

Ω

 

±

3% rdg

±

10 dgt 

)

)

)

 Continuity 

check

 

 

2K

Ω

 

Continuity beeper 

Approx. 300

Ω

 

250V rms 

                |

 

Diode test 

2V 

±

10% rdg

±

3 dgt 

250V rms 

 

 
 
 

Summary of Contents for M-2100

Page 1: ...lectronic design Before you use your new instrument read this Instruction Manual completely and familiarize yourself thoroughly with all functions Keep this manual carefully to take out whenever you n...

Page 2: ...nd etc Before operating this instrument familiarize yourself with all instructions outlined in this manual Always check to make sure that the function switch is set to the proper position When making...

Page 3: ...ower off The meter is set to power off mode approx 10 minutes after the power switch on Operating temperature 0 to 40 80 RH non condensing Strange temperature 10 to 60 70 RH non condensing Power suppl...

Page 4: ...nge to be measured Start the measurement at top range and then work down to lower range Open the CT and clamp it to the conductor to be measured at the center of CT Close CT completely Read the curren...

Page 5: ...n Connect the plug of red test lead into the V terminal and the plug of black test lead into the COM terminal Set the range selector switch to ACV range Contact the tips of the test leads to the circu...

Page 6: ...to rain or moisture Do not operate the tester in the presence of flammable gases or fumes CAUTION To avoid damage to the tester disconnect test leads before changing functions Do not exceed the maximu...

Page 7: ...TION Be sure all voltage is turned OFF in the circuit before making diode test 5 REPLACEMENT OF BATTERIES AND When the battery voltage falls below a specified voltage value the B mark will appear in t...

Page 8: ...sufficient internal inspections but if you find any defect due to the fault in our workmanship or the original parts please contact the dealer where you bought the instrument The warranty period is 12...