MULTI MEASURING INSTRUMENTS M-2010 Instruction Manual Download Page 3

3.

 

SPECIFICATIONS 

 

Safety standard : Meets the requirements for double insulation to IEC 1010-2-032, 

IEC 1010-1(1995), EN 61010-1(1995) installation Category

600V phase to earth. 

E.M.C. standard : The instrument meets EN 50081-1 and EN 50082-1(1992) 
Withstanding voltage : AC 5500V, 1 minute (between outer case and core of CT)     

Measuring method : Dual integration mode 
Jaw opening capability : 40mm

φ

 

Display : 3 1/2 digit LCD max. reading of 1999 and annunciators 

Over range indication : Blanking of all digits except MSD1 (Except AC/DC 600V 

and AC 600A range)   

Low battery indication : "B" mark on LCD readout 

Sampling : 2 times/s 
Data hold indication : "D

H" mark on LCD readout 

Auto power off : The meter is set to power off mode approx. 10 minutes after the 

power switch on. 

Operating temperature : 0

 to 40

80%RH (non-condensing) 

Strange temperature :

10

 to 60

70%RH (non-condensing) 

Power supply : 1.5V (“ AAA” size, R03) x2 

Power consumption and battery life : Approx. 3.5mW, 500 hours continuous. 

Size : 70(W)x223(H)x34(D)mm 
Weight : Approx. 425g   

Accessories : Carrying case…………..1 

Instruction manual……1 
Batteries…………………2 

Test lead…………………1set 

 
 

Measuring range (23

℃±

5

80% RH ) : 

 

 
 

 

 

Range 

Accuracy

Max. input 

~A 

(50/60Hz) 

Manual range

20A 

±

1.5% rdg

±

10 dgt 

AC 600A 

200A

 

600A

±

1.0% rdg

±

8 dgt 

~V 

(50/60Hz) 

… V 

Auto range 

2V 

±

0.7% rdg

±

5 dgt 

AC/DC 

600V rms 

20V 

±

1.2% rdg

±

5 dgt 

200V

 

600V

 

 

 

Ω

 

(OHM) 

 

Auto range 

200

Ω

 

±

1.2% rdg

±

5 dgt 

Input protection

 

 

250V rms 

2K

Ω

 

 

20K

Ω

 

 

200K

Ω

 

 

2000K

Ω

 

 

20M

Ω

 

±

3% rdg

±

10 dgt 

)

)

)

 Continuity

check   

2K

Ω

 

 

Continuity beeper

Approx. 300

Ω

 

250V rms 

                |

 

Diode test 

2V

 

±

10% rdg

±

3 dgt 

250V rms 

 

Summary of Contents for M-2010

Page 1: ...Before you use your new instrument read this Instruction Manual completely and familiarize yourself thoroughly with all functions With proper use and care your tester will give you years of satisfact...

Page 2: ...nd etc Before operating this instrument familiarize yourself with all instructions outlined in this manual Always check to make sure that the function switch is set to the proper position When making...

Page 3: ...LCD readout Auto power off The meter is set to power off mode approx 10 minutes after the power switch on Operating temperature 0 to 40 80 RH non condensing Strange temperature 10 to 60 70 RH non cond...

Page 4: ...a range appropriate to the current to be measured Start the measurement at top range and then work down to lower range Clamp the conductor of the circuit at the center of CT Read the current value in...

Page 5: ...onnect the plug of red test lead into the V terminal and the plug of black test lead into the COM terminal Set the range selector switch to ACV range Contact the tips of the test leads to the circuit...

Page 6: ...rain or moisture Do not operate the tester in the presence of flammable gases or fumes CAUTION To avoid damage to the tester disconnect test leads before changing functions Do not exceed the maximum i...

Page 7: ...d OFF in the circuit before making diode test 6 REPLACEMENT OF BATTERIES AND FUSE When the battery voltage falls below a specified voltage value the B mark will appear in the display If this occurs re...

Page 8: ...this instrument always pack it in its original or equivalent packing material and pack together with name address telephone number and the warranty documentation To ensure speedy and reliable repair a...

Reviews: