MULTI MEASURING INSTRUMENTS M-140HC Instruction Manual Download Page 10

 

4. REPAIR SERVICE 

When requesting for repair service, please bring the instrument directly to the dealer where 

you bought. 

When mailing the instrument, always pack it in its original or equivalent packing materials to 

avoid any damage during the transportation and also put together with documents showing 

your name, address, phone number and defect point. 

 

5. WARRANTY 

This instrument is sent out from our factory after the sufficient internal inspections but if you 

find any defect due to the fault in our workmanship or the original parts, please contact the 

dealer where you bought the instrument. 

 

The warranty period is 12 months from the date of purchase and the instrument shall be 

repaired at free of charge, provided that we judge the cause of defect is obviously resulted 

from our responsibility. 

 

GURANTEE REGULATIONS 

1.  This instrument is warranted for the operation under normal use for 12 months from the 

date of purchase. 

2.  This warranty does not cover the following defects: 

a. Defect caused from the improper use and operation. 

b. Defect caused from the use, operation and storage beyond the original specifications, 

designs and conditions. 

c. Defect caused from the renovations or repairs done by someone else than us or our 

representatives. 

d. Defect not caused from our responsibilities.

 

Summary of Contents for M-140HC

Page 1: ...instruction manual completely and apply this instrument correctly Keep this instruction manual carefully to take out whenever you need MULTI MEASURING INSTRUMENTS CO LTD Akihabara Murai Bldg 7F 1 26...

Page 2: ...from mis operations WARNING POSSIBLE ELECTRICAL SHOCK This instrument is for the use of low voltage circuit Do not make measurements of power lines carrying more than AC 600V Before use check and conf...

Page 3: ...ng Part Measuring Function AC Leakage Current loading current Phase current of hi voltage circuit measuring at low voltage corresponding field Measuring Method CT clamp method max applicable conductor...

Page 4: ...Consumption approx 3 5mA approx 150h for continuous use Dimension Weight 45 W x195 H x24 D mm approx 180g Accessories AAA battery LR03 x 3 installed in the instrument instruction manual x 1 soft carry...

Page 5: ...h By push one time DH sign will be on LCD and the data will be hold By push once more this function will be released m Conversion Switch In case of hi voltage phase current measurement the storey capa...

Page 6: ...ve the battery cover to the direction of arrow mark 2 Pick up the exhausted batteries 3 Confirm the polarities and put the new batteries 4 Replace the battery cover to the original position and fix sc...

Page 7: ...r range OL mark will appear on LCD use data hold where displayed value cannot be seen clearly POSSIBLE ELECTRICAL SHOCK For safety use the instrument in circuit less than 600V Before operation confirm...

Page 8: ...3 Phase Current Measurement of Hi Voltage Circuit with shielded grounding line 1 Measurement of CVT Cable In case of CVT cable as the right drawing this instrument can measure phase current by clampin...

Page 9: ...nt of CV Cable Move CV cable to the search coil of CT like as at the right drawing and read the max value by keeping close and turning the instrument for 90o Set range switch from OFF to CV position d...

Page 10: ...contact the dealer where you bought the instrument The warranty period is 12 months from the date of purchase and the instrument shall be repaired at free of charge provided that we judge the cause o...

Reviews: