MU columbia aqua FC-550 Manual Download Page 9

9

6.6 HOW TO SELECT THE QUANTITY OF WATER TO BE 

DISPENSED 

PREDETERMINED QUANTITIES

1.  Press the QUANTITY icon to select the quanity of 

water to be dispensed (1 press -> 550 ml, 2 presses -> 

1500 ml, 3 presses -> 120 ml) and then press the icon 

DISPENSATION. 

If you do not select a quantity of water, by default, 

120 ml will be dispensed. 

FREE QUANTITY

1. Touch and hold the DISPENSATION icon. While hol-

ding down the DISPENSATION icon, water will be drawn. 

When you lift your finger from the icon, the dispensing 

will cease (except in hot water mode).  

The quantity of water dispensed may vary depen-

ding on the inlet pressure.

During dispensation, this can be stopped by pres-

sing the DISPENSATION icon. 

In the hot water mode, if the quantity of water is 

not selected, 120 ml will be despensed. 

6.7 ENERGY SAVING MODE

This system lowers its consumption of electricity when, 

intelligently, it disconnects the cooling system when it 

detects darkness, as during the evening, through the 

integrated light sensor.  

ACTIVATE

Press and keep pres-

sed for more than 4 

seconds the QUAN-

TITY ICON. The blue 

DISPENSATION icon 

will blink 3 times with 

a sound (ding-dong) 

indicating that it has been activated correctly. 

TOUCH

TOUCH

TOUCH

DEACTIVATE

Press and keep pres-

sed for more than 4 

seconds the QUAN-

TITY ICON. The white 

DISPENSATION icon 

will blink 3 times 

with a sound (ding-

dong) indicating that it has been deactivated correctly.  

Regardless of whether saving mode is activated, 

when the light sensor detects darkness, the bri-

ghtness of the control panel icons will decrease 

to prevent glare. 

6.8 BUTTON BLOCKING

Avoid damage to children or accidents due to careless-

ness.

ACTIVATE / DEACTIVATE THE LOCKING OF ALL BUT-

TONS 

The locking of all buttons is activa-

ted by touching the LOCK icon for 

more than 5 seconds. This lights up 

indicating that it has been activated 

correctly.

The lock is deactivated by touching the LOCK icon for 

more than 5 seconds. It turns off indicating that it has 

been deactivated correcty.  

LOCKING INDIVIDUAL BUTTONS

Press any icon that you wish to lock (HOT/AMBIENT/

COLD) together with the LOCK icon for more than 5 se-

conds.

Unlock the blicking icon together with the LOCK icon for 

more than 5 seconds. 

Example locking

the hot water icon

If you touch a locked icon, it flashes and a sound 

sounds. 

If you lock all icons when an individual lock was 

activated, all icons will be locked. If you subse-

quently unlock all the icons, you will return to the 

previous individual lock mode.  

The locks are initialized when disconnecting and 

connecting to the power supply.

Summary of Contents for columbia aqua FC-550

Page 1: ...Technical Manual Service Booklet MU FC 550...

Page 2: ......

Page 3: ...0 5 PRIOR WARNINGS 6 OPERATION OF THE EQUIPMENT 7 HOW TO ACCESS THE FILTERS 8 TECHNICAL CHARACTERISTICS 9 INSTALLATION 10 CLEANING AND MAINTENANCE 11 SANITIZATION PROCEDURE 12 TROUBLESHOOTING 13 WARRA...

Page 4: ...curity System for Hot Water ROOM TEMPERATURE Production of Room Temperature Water COLD Cold water production VENTILATION SYSTEM Forced ventilation system for the outdoors large loads and very warm reg...

Page 5: ...ENT USED BY KINETICO 550 Depending on the KINETICO water dispenser model are availble with different types of treatment microcarbon and NANOFACT filtration 4 1 WHAT IS MICROCARBON Microcarbon filtrati...

Page 6: ...d outdoors ATTENTION After its installation the equipment should not be connected immediately to a power source It should be left to rest for 2 hours once it has been installed in the desired spot Thi...

Page 7: ...ded particles chloride their derivatives and other organic substances are retained and the water then passes through the NANOFACT filter where smaller particles are retained as well as viruses and bac...

Page 8: ...r the back HOT switch must be in the ON position The frontal HOT will light up 2 Press the hot water icon 1 3 cup of the DISPENSA TION icon will turn red 3 Press the DISPENSATION icon Then hot water w...

Page 9: ...ctly TOUCH TOUCH TOUCH DEACTIVATE Press and keep pres sed for more than 4 seconds the QUAN TITY ICON The white DISPENSATION icon will blink 3 times with a sound ding dong indicating that it has been d...

Page 10: ...more than 5 se conds The DISPENSATION icon will light blue indica ting that cold water has been programmed as the de fault water type CHANGE FROM COLD TEMP TO ROOM TEMP Touch the AMBIENT room temp wa...

Page 11: ...11...

Page 12: ...CT reduces the flavour and smell of the water as well as its organic components It retains microorganisms as well as viruses and bacte ria Based on the characteristics of the water to be treated Opera...

Page 13: ...s as necessary throughout the installation commissioning and maintenance of the equipment in order to avoid the risk of contaminating the equipment by not handling it properly Install the adapter from...

Page 14: ...bling the equipment plan all the material that you will need to carry out the maintenance operations and the space ne cessary for it Work in a properly lit place in adequate hygienic conditions and wi...

Page 15: ...off valve to the equipment enabling it to start up and allowing the sanitizing pro duct to go through Keep the inlet valve in that position and extract a cup of water for reach dispenser in order to...

Page 16: ...ion The source is contaminated The rear switch COLD is in the OFF position The customer fills up bottles of cold water and empties the cold water tank The cold system is damaged or the re frigerant ga...

Page 17: ...17...

Page 18: ...t ensure that the installed equipment is suitable for improving the quality of the water to be treated in parti cular according to the characteristics of the equipment and the regulations in force The...

Page 19: ...INSTALLER read this manual carefully If in doubt contact your dealer s Technical Support Service T A S The data marked with the symbol must be filled in by the technician installer and trans cribed by...

Page 20: ...ANCE PREPARATION HYGIENISATION OTHER FULL MAINTENANCE PREPARATION HYGIENISATION OTHER TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP ORDINARY OUTSTANDING WARRANTY...

Page 21: ...ARATION HYGIENISATION OTHER FULL MAINTENANCE PREPARATION HYGIENISATION OTHER TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP TECHNICIAN STAMP ORDINARY OUTSTANDING WARRANTY ORDINARY...

Page 22: ...22 16 NOTES...

Page 23: ...23 16 NOTES...

Page 24: ...MU...

Reviews: