4.5 12/16/18V2000Gx5-TB engine data, emissions optimized
Explanation
Abbr.
Meaning
DL
Ref. value: Continuous power
BL
Ref. value: Fuel stop power
A
Design value
G
Guaranteed value
R
Guideline value
L
Limit value, up to which the engine can be operated, without change (e.g. of power settings).
N
Not yet defined value
-
Not applicable
X
Applicable
Reference condition
Description
12V 2000
G45-TB
12V 2000
G85-TB
16V 2000
G45-TB
16V 2000
G85-TB
18V 2000
G85-TB
Application group
3B
3B
3B
3B
3B
Intake air temperature
°C
25
25
25
25
25
Charge-air coolant tempera-
ture
°C
45
45
45
45
45
Raw-water inlet temperature
°C
-
-
-
-
-
Barometric pressure
mbar
1000
1000
1000
1000
1000
Site altitude above sea level
M
100
100
100
100
100
Power-related data (power ratings are net brake power as per ISO 3046)
Description
12V 2000
G45-TB
12V 2000
G85-TB
16V 2000
G45-TB
16V 2000
G85-TB
18V 2000
G85-TB
Rated engine speed
A
rpm
1800
1800
1800
1800
1800
Continuous power ISO 3046
(10% overload possible) (pow-
er range DIN 6280, ISO 8528)
A
kW
710
810
915
1010
1191
General conditions (for maximum power)
Description
12V 2000
G45-TB
12V 2000
G85-TB
16V 2000
G45-TB
16V 2000
G85-TB
18V 2000
G85-TB
Intake depression (new filter)
A
mbar
15
15
15
15
15
Intake depression, max.
L
mbar
50
50
50
50
50
Exhaust overpressure
A
mbar
30
30
30
30
30
Exhaust gas overpressure,
max.
L
mbar
85
85
85
85
85
MS15019/04E 2016-02
| Technical Data | 43
TIM-ID: 0000010949 - 002